Campbell Hausfeld RP3175, IN718402AV User Manual

See Warranty on page 3 for important information about commercial use of this product.
Operating Instructions RP3175
Please read and save these instructions. Read carefully before attempting to assemble, install, operate or maintain the product described. Protect yourself and others by observing all safety information. Failure to comply with instructions could result in personal injury and/or property damage! Retain instructions for future reference.
12-Volt Tire and
Raft Inflator
Description
The RP3175 12-volt infl ator has a high pressure air hose for emergency roadside tire infl ation and to infl ate bicycle tires, soccer balls, and other sports equipment. The infl ators also have a high volume air outlet for infl ating air mattresses, rafts, and other low pressure infl atables. The infl ators include a work light for nighttime emergencies. A 10-amp fuse is located inside the 12-volt DC plug.
Unpacking
After unpacking the unit, inspect carefully for any damage that may have occurred during transit.
Safety Guidelines
This manual contains information that is very important to know and understand. This information is provided for SAFETY and to PREVENT EQUIPMENT PROBLEMS. To help recognize this information, observe the following symbols.
Danger indicates
an imminently hazardous situation which, if not avoided, WILL result in death or serious injury.
Warning indicates
a potentially hazardous situation which, if not avoided, COULD result in death or serious injury.
Caution indicates a potentially hazardous situation which, if not avoided, MAY result in minor or moderate injury.
Notice indicates
important information, that if not followed, may cause damage to equipment.
Hose, Cord, Accessory Storage
High volume air outlet
Universal
Figure 1
adapter
General Safety Information
ANY MISUSE OF UNIT COULD CAUSE PROPERTY OR EQUIPMENT DAMAGE AND/OR PERSONAL INJURY.
This manual contains safety, operational and maintenance information. Contact your Campbell Hausfeld representative if you have any questions.
CALIFORNIA PROPOSITION 65
This product or its
contain chemicals, including lead, known to the State of California to cause cancer and birth defects or other reproductive harm. Wash hands after handling.
GENERAL
a. To reduce the risks of
electric shock, fire, and injury to persons, read all the instructions before using the unit.
power cord may
MANUAL
Pressure gauge
Work light
Raft inflator
Specifications
Maximum Pressure . . . . . . . . . . 150 psi
Continuous 0.66 SCFM @ 0 psi
Volume . . . . . . . . . 0.54 SCFM @ 30 psi
Weight . . . . . . . . . . . . . . . . . . . 3.0 lbs.
Voltage . . . . . . . . . . . . . . . . 12-Volt DC
Amp Draw . . . . . . . . . . .5 amp @ 0 psi
Cord length . . . . . . . . . . . . . . . 11 feet
Fuse . . . . . . . . . . . . . . . . . . . . . .10 Amp
b. Be thoroughly familiar with the
controls and the proper use of the equipment. Follow all instructions. Contact your Campbell Hausfeld representative if you have any questions.
c. Only persons well acquainted with
these rules of safe operation should be allowed to use the unit.
REMINDER: Keep your dated proof of purchase for warranty purposes!
Attach it to this manual or file it for safekeeping.
For parts, product & service information
visit www.chpower.com
IN718402AV 9/09
Operating Instructions RP3175
Important Safety Instructions (Continued)
Do not leave the
infl ator unattended
while the unit is running. Never
exceed the recommended pressure for any infl atable object. Do not over infl ate objects. Over infl ation could cause property damage and/or personal injury.
The universal
adapter must be locked to secure the infl ation accessories. Use extreme caution when using infl ation accessories.
Always put the car
in park; set the emergency brake; and chock the wheels before using the infl ator or property damage and/or personal injury could occur.
Always use a
separate pressure gauge to check the actual pressure in tires and in low pressure infl atable objects.
Infl ator must cool
for 20 minutes after 20 minutes of continuous oper-ation. The Infl ator is not designed to operate continuously for more than 20 minutes.
Do not use infl ator
on high pressure tires used on large trucks, trailers or tractors. The infl ator is not designed to operate for the length of time necessary to infl ate these tires.
Make sure the
universal adapter touches the core or tire valve stem.
Operation
For use with 12-volt
rated 10 amps or higher. Do not use with older 8 amp cigarette lighter receptacles.
Overinfl ation can be dangerous.
Pay attention while infl ating
low pressure items to prevent
TIRES
1. Remove valve stem cap.
2. Attach the universal adapter (see Figure 2) from the inflator to the valve stem with the lever in the up position. Be sure to press universal adapter down over valve stem threads completely. When universal adapter is firmly in place, press locking lever down to lock onto valve stem.
Open
Figure 2
3. Plug power cord into power outlet.
4. Turn on inflator until desired pressure is reached.
5. Check that the tire pressure is correct.
DC power outlets
overinfl ation.
Lock
Universal Adapter
Valve Stem
INFLATABLES
1. Push flexible plastic hose onto high volume air outlet located on side of inflator.
2. Place end of hose into opening of inflatable using the appropriate nozzle.
3. Plug power cord into power outlet.
4. Turn on inflator.
5. Once object being filled is firm, turn off inflator.
User - Maintenance Instructions
FUSE REPLACEMENT
NEVER replace a blown fuse with a fuse having a higher rating.
1. Unscrew end of plug counter­clockwise to remove fuse.
2. If fuse is blown, replace with a new 10-amp fuse. Always replace a blown fuse with the same size fuse.
3. Reassemble plug. Do not overtighten.
TECHNICAL SERVICE
Please call our Tool Hotline at 1-800­543-6400 with any questions regarding the operation or repair of this unit or for additional copies of this manual.
UNIT REPAIR
Only qualified personnel should repair the unit and they should use genuine Campbell Hausfeld replacement parts and accessories, or parts and accessories which perform equivalently.
STORAGE
The unit should be stored in a cool dry place.
www.chpower.com
2
Operating Instructions RP3175
Limited Warranty
1. DURATION: From the date of purchase by the original purchaser as follows: One (1) Year.
2. WHO GIVES THIS WARRANTY (WARRANTOR): Campbell Hausfeld / Scott Fetzer Company, 100 Production Drive, Harrison, Ohio, 45030, Telephone: (800) 543-6400
3. WHO RECEIVES THIS WARRANTY (PURCHASER): The original purchaser (other than for purposes of resale) of the Campbell Hausfeld product.
4. WHAT PRODUCTS ARE COVERED BY THIS WARRANTY: Any Campbell Hausfeld nailer, stapler, air tool, spray gun, inflator or air accessory supplied or manufactured by Warrantor.
5. WHAT IS COVERED UNDER THIS WARRANTY: Substantial defects in material and workmanship which occur within the duration of the warranty period.
6. WHAT IS NOT COVERED UNDER THIS WARRANTY:
A. Implied warranties, including those of merchantability and FITNESS FOR A PARTICULAR PURPOSE ARE LIMITED
FROM THE DATE OF ORIGINAL PURCHASE AS STATED IN THE DURATION. If this product is used for commercial, industrial or rental purposes, the warranty will apply for ninety (90) days from the date of purchase. Some States do not allow limitation on how long an implied warranty lasts, so the above limitations may not apply to you.
B. ANY INCIDENTAL, INDIRECT, OR CONSEQUENTIAL LOSS, DAMAGE, OR EXPENSE THAT MAY RESULT FROM ANY
DEFECT, FAILURE, OR MALFUNCTION OF THE CAMPBELL HAUSFELD PRODUCT. Some States do not allow the exclusion or limitation of incidental or consequential damages, so the above limitation or exclusion may not apply to you.
C. Any failure that results from an accident, purchaser’s abuse, neglect or failure to operate products in accordance
with instructions provided in the owner’s manual(s) supplied with product. Accident, purchaser's abuse, neglect or failure to operate products in accordance with instructions shall also include the removal or alteration of any
safety devices. If such safety devices are removed or altered, this warranty is void. D. Normal adjustments which are explained in the owner’s manual(s) provided with the product. E. Items or service that are normally required to maintain the product, i.e. o-rings, springs, bumpers, debris shields,
driver blades, fuses, batteries, gaskets, packings or seals, fluid nozzles, needles, sandblast nozzles, lubricants,
material hoses, filter elements, motor vanes, abrasives, blades, cut-off wheels, chisels, chisel retainers, cutters,
collets, chucks, rivet jaws, screw driver bits, sanding pads, back-up pads, impact mechanism, or any other
expendable part not specifically listed. These items will only be covered for ninety (90) days from date of
original purchase. Underlined items are warranted for defects in material and workmanship only. F. Cosmetic defects that do not interfere with the product’s function.
7. RESPONSIBILITIES OF WARRANTOR UNDER THIS WARRANTY: Repair or replace, at Warrantor’s option, products or components which are defective, have malfunctioned and/or failed to conform within duration of the warranty period.
8. RESPONSIBILITIES OF PURCHASER UNDER THIS WARRANTY:
A. Provide dated proof of purchase and maintenance records. B. Call Campbell Hausfeld (800) 543-6400 to obtain your warranty service options. Freight costs must be borne by
the purchaser.
C. Use reasonable care in the operation and maintenance of the products as described in the owner’s manual(s).
9. WHEN WARRANTOR WILL PERFORM REPAIR OR REPLACEMENT UNDER THIS WARRANTY: Repair or replacement will be scheduled and serviced according to the normal work flow at the servicing location, and depending on the availability of replacement parts.
This Limited Warranty applies in the United States, Canada and Mexico only and gives you specific legal rights. You may also have other rights which vary from state to state or country to country.
3
www.chpower.com
Voir la Garantie à la page 6 pour de l’information importante sur l’utilisation commercial de ce produit.
Instructions d’Utilisation RP3175
S’il vous plaît lire et conserver ces instructions. Lire attentivement avant de monter, installer, utiliser ou de procéder à l’entretien du produit décrit. Se protéger ainsi que les autres en observant toutes les instructions de sécurité, sinon, il y a risque de blessure et/ou dégâts matériels! Conserver ces instructions comme référence.
Gonfleur de pneu et
de radeau de 12 volts
Description
Les gonfl eur de 12 volts RP3175 ont un tuyau d’air haute pression pour gonfl er
Tuyau, cordon, stockage
d’accessoires les pneus en situations d’urgence sur la route et gonfl er les pneus de bicyclette, les ballons de soccer, les ballons de plage et autre équipement de sport. Les gonfl eurs ont aussi une sortie d’air à volume élevé pour gonfl er les matelas pneumatiques, les radeaux et autres articles gonfl ables à basse pression. Ces gonfl eurs incluent une lumière de travail pour les urgences nocturnes. Un fusible de 10 A se trouve à l’intérieur de la prise 12 V c.c.
Déballage
Dès que l’appareil est déballé, l’inspecter attentivement pour tout signe de dommages en transit.
Sortie d’air de volume élevé
Directives de Sécurité
Ce manuel contient de l’information très importante qui est fournie pour la SÉCURITÉ et pour ÉVITER LES PROBLÈMES D’ÉQUIPEMENT. Rechercher les symboles suivants pour cette information.
Danger indique
une situation dangereuse imminente qui MÈNERA à la mort ou à des blessures graves si elle n’est pas évitée.
Avertissement
indique une situation potentiellement dangereuse qui, si elle n’est pas évitée, POURRAIT mener à la mort ou à de graves blessures.
Attention
indique une situation potentiellement dangereuse qui, si elle n’est pas évitée, PEUT mener à des blessures mineures ou modérées.
Avis indique
de l’information importante qui pourrait endommager l’équipement si elle n’est pas respectée.
Figure 1
Généralités Sur la Sécurité
TOUTE UTILISATION INCORRECTE DE L’UNITÉ PEUT CAUSER DES DOMMAGES À LA PROPRIÉTÉ OU À L’ÉQUIPEMENT OU ENCORE DES BLESSURES.
Ce manuel contient des informations concernant la sécurité, le fonctionnement et l’entretien. Contacter votre représentant Campbell Hausfeld si vous avez des questions.
PROPOSITION 65 DE CALIFORNIE
Ce produit ou son
contenir des produits chimiques, y compris du plomb, relevés par l'État de Californie comme cause de cancer, d'anomalies congénitales ou d'autres problèmes reproductifs. Lavez-vous les mains après toute manipulation.
Adaptateur
universel
cordon peuvent
Manomètre
Lumière de travail
Gonfleur de radeau
Spécifications
Pression maximum . . . . . . . .1034 kPa
Volume sans 0,02 m3/min @ 0 kPa interruption . . 0,02 m
Poids . . . . . . . . . . . . . . . . . . . . . 1,36 kg
Tension . . . . . . . . . . . . . . . .12 volts c,c,
Débit d’ampères . . 5 ampères @ 0 kPa
Longueur de cordon . . . . . . . . .3,35 m
Fusible . . . . . . . . . . . . . . . . 10 Ampères
GÉNÉRALITÉ
a. Pour réduire les risques
de chocs électriques, d’incendie ou de blessures aux personnes, lire toutes les instructions avant d’utiliser l’unité.
b. Se familiariser avec ce produit, ses
commandes et son utilisation. Suivez toutes les instructions. Contacter votre représentant Campbell Hausfeld si vous avez des questions.
3
/min @ 207 kPa
MANUEL
MÉMENTO: Gardez votre preuve datée d'achat à fin de la garantie!
Joignez-la à ce manuel ou classez-la dans un dossier pour plus de sécurité.
4-Fr
IN718402AV 9/09
Loading...
+ 8 hidden pages