Burkert 8070 User Manual [en, de, fr]

www.burkert.com
We reserve the right to make technical changes without notice.
Technische Änderungen vorbehalten.
Sous réserve de modifications techniques.
Type 8022
Flow Transmitter / Pulse divider Durchflusstransmitter / Impulsteiler Transmetteur de débit / Diviseur d’impulsions
Quickstart
English (from device Version 2) Deutsch (ab Geräte-Version 2) Français (à partir de la version 2 de l'appareil)
2
1 QUICKSTART
Keep these instructions in a location which is easily accessible to every user and make these instructions available to every new owner of the device.
Important Safety Information!
Read the quickstart carefully and thoroughly. Study in particular the chapters entitled Basic Safety Instructions and Intended Use.
▶ The quickstart must be read and understood.
The quickstart explains, using examples, how to install and start-up the device.
A detailed description of the device can be found in the operating instructions for type 8022.
The operating instructions can be found on the enclosed CD and on the Internet at:
www.burkert.com
English
3
1.1 Symbols
The following symbols are used in these instructions.
Caution!
Warns of a possible danger!
▶ Failure to observe this warning may result in a medium
or minor injury.
note!
Warns of damage to property!
Indicates important additional information, tips and recommendations.
→ designates a procedure that must be carried out.
1.2 Definition of the Term “Device”
In these instructions, the term “device” always refers to the flow transmitter or pulse divider Type 8022.
English
4
2 INTENDED USE
Use of this device that does not comply with the instructions could present risks to people, nearby installations and the environment.
▶ The flow transmitter or pulse divider is an electronic
module that is designed for use in industrial environ­ments. The electronic module must be associated to a
Bürkert flow sensor. ▶ Do not use the device outdoors. ▶ Protect the device against electromagnetic interference
and ultraviolet rays. ▶ Use the device in compliance with the characteristics
and commissioning and use conditions specified in the
contractual documents and in the user manual. ▶ Requirements for the safe and proper operation of the
device are proper transport, storage and installation, as
well as careful operation and maintenance. ▶ Only use the device as intended.
▶ If exporting the system/device, observe any existing
restrictions.
English
5
3 BASIC SAFETY
INSTRUCTIONS
These safety instructions do not make allowance for any
• contingencies and events which may arise during the ins­tallation, operation and maintenance of the devices.
• local safety regulations – the operator is responsible for observing these regulations, also with reference to the installation personnel.
note!
Electrostatic sensitive components/modules!
The device contains electronic components, which react sensitively to electrostatic discharge (ESD). Contact with electrostatically charged persons or objects is hazardous to these components. In the worst case scenario, they will be destroyed immediately or will fail after start-up.
• Observe the requirements in accordance with EN 61340-5-1 and 5-2 to minimize/avoid the possibility of damage caused by a sudden electrostatic discharge!
• Also, ensure that you do not touch electronic components
when the power supply voltage is present!
English
6
Various dangerous situations
▶ Guarantee a set or controlled restarting of the process,
after a power supply interruption.
▶ Use the device only if in perfect working order and
in compliance with the instructions provided in the instruction manual.
▶ Observe the general technical rules when installing and
using the device. ▶ Do not use this device in explosive atmospheres. ▶ Do not use this device in an environment incompatible
with the materials it is made of. ▶ Do not subject the device to mechanical loads (e.g. by
placing objects on top of it or by using it as a step). ▶ Do not make any external or internal modifications to
the device.
English
7
4 GENERAL INFORMATION
4.1 Contact Address
To contact the manufacturer of the device, use following address:
Bürkert SAS Rue du Giessen BP 21 F-67220 TRIEMBACH-AU-VAL The addresses of our international sales offices are avai-
lable on the internet at: www.burkert.com
4.2 Warranty
The warranty is only valid if the Type 8022 is used as intended in accordance with the specified application conditions.
4.3 Information on the Internet
The operating instructions and data sheets for Type 8022 can be found on the Internet at: www.burkert.com
English
8
5 DESCRIPTION
5.1 Intended application area
The flow transmitter / pulse divider Type 8022 is designed for use in industrial environments, in particular for the area of control technology.
5.2 General description
The device type 8022 is an electronic module that, when it is combined with a flow sensor, converts into a flow rate the fluid velocity measured by the sensor.
The electronic module may be fitted with a display and configuration unit.
The electronic module may operate as a flow transmitter thanks to a 4-20 mA current output, or as a pulse divider. By default, it operates as a flow transmitter. The display and configuration unit makes it possible to change the operating mode into pulse divider.
5.3 Combined sensor
• The flow transmitter type 8022 must be combined to a Bürkert flow sensor of the following types: 8020 Low Power, 8030 Low Power or 8070 Low Power.
• The pulse divider type 8022 can be combined to a flow sensor type 8020 with a pulse output, 8030 with a pulse output or 8070 with a pulse output.
English
9
5.4 Functions
note
The device is not tight when the display and configu­ration unit is removed.
• Screw the cover with order code 670549 on the device as soon as the display and configuration unit is removed.
The display and configuration unit is only required to indicate the flow rate or to configure the device type 8022. It can be removed after the settings have been made.
• When operating as a flow transmitter, the 8022 converts the frequency signal generated by the combined Bürkert flow sensor into an analogue 4-20 mA current signal (2-wire connection).
• When operating as a pulse divider, the 8022 converts the frequency signal generated by the combined Bürkert flow sensor into an adjustable frequency signal (3-wire connection).
English
10
6 TECHNICAL DATA
6.1 Conformity
The device is approved by EC and conforms to the stan­dards mentioned on the EC declaration of conformity.
6.2 Operating conditions
Ambient temperature (operating)
-10 °C...+60 °C
Protection class IP65 according to EN 60529, the
device being wired and the cable gland tightened or the female con­nector plugged-in and tightened
Combined flow sensor
• Flow transmitter 8022
• Pulse divider 8022
• only Bürkert flow sensors types 8020 Low Power, 8030 Low Power or 8070 Low Power.
• any flow sensor 8020 with pulse output, 8030 with pulse output or 8070 with pulse output.
6.3 Mechanical Data
Dimensions (L x l x H) 70 x 32 x 42,5 mm
English
11
Fastening
• device without display and configuration unit
• device with display and configuration unit
• 1 M3 x 35 screw
• 1 M3 x 45 screw
Housing material PA/PC Material of the seals
• seal for the sensor fixed connector
• seal for the cover
• NBR
• EPDM
6.3.1 Electrical Data
Electrical connection
• 4-pin terminal strip, 1.5 mm
2
max. wire section, 6 - 7 mm cable diameter
• M12 male fixed connector
Supply voltage V+ : 12-30 V DC +- 10%,
residual ripple < 5%
Frequency input 1-600 Hz, sensor power supply
approx. V+ - 1 V
English
12
4-20 mA output
• Accuracy
• Min. voltage drop at the device terminals
• Loop impedance
• +/- 1,5% of the full scale
• < 10 V at 20 mA
• max. 100 W at 12 VDC, max. 700 W at 24 VDC, max. 1000 W at 30 VDC
NPN/PNP output open collector, 50 mA max.
current, frequency up to 600 Hz
Power consumption < 200 mW
English
13
7 ASSEMBLY, INSTALLATION
7.1 Assembly of Type 8022
note!
For the fault-free operation of the Type 8022 observe the following during installation:
• When screwing to the sensor, ensure the seal is seated correctly.
▶ Torque the screw to a value between 0.2 and 0.3 Nm,
in order not to damage the housing. With a damaged housing, correct operation cannot be guaranteed.
Fig. 1 shows how Type 8022 is screwed to the sensor.
English
14
Fig. 1: Installing Type 8022 on the sensor
English
15
7.2 Electrical Installation
The electrical connection of the device is made on a terminal strip via cable gland, or an M12 male fixed connector.
Terminal assignment
1
NPN
2
PNP
3
12 - 30 V DC
4
GND
Fig. 2: Terminal assignment, version with cable gland
Pin assignment 1
12 - 30 V DC
2
NPN
3
GND
4
PNP
Fig. 3: Pin assignment, M12 male fixed connector
English
16
→ Wire the device following the possibilities described
below.
7.2.1 Connection of the flow transmitter
4 - 20 mA
When operating as a flow transmitter, the NPN and PNP outputs have no function.
8022
12 - 30 V DC
GND
12 - 30 V DC
Fig. 4: Connection of the flow transmitter
English
17
7.2.2 Connection of the pulse divider
Connection
of the PNP
output
12 - 30 V DC
PNP
GND
8022
e.g. PLC
GND
IN
12 - 30 V DC
NPN
GND
Connection
of the NPN
output
8022 e.g. PLC
GND
IN
V+
V+
Fig. 5: Connection of the pulse divider
English
18
8 COMMISSIONING
note!
• Only power on the device when the cover is closed.
• Switch off the device before removing the operating
unit.
9 SETTING AND FUNCTIONS
→ Parameterize the device depending whether it is used
as a flow transmitter or a pulse divider. Refer to the instruction manual on the delivered CD.
10 MAINTENANCE
The flow transmitter / pulse divider Type 8022 is maintenance­free when operated according to these operating instructions.
English
19
11 PACKAGING, TRANSPORT,
STORAGE, DISPOSAL
note!
Transport damage!
Inadequately protected equipment may be damaged during transport.
• During transportation protect the device against
moisture and dirt in shock-resistant packaging.
• Do not allow the temperature to exceed or drop below
the permitted storage temperature.
Incorrect storage may damage the device.
• Store the device in a dry and dust-free location!
• Storage temperature. -20 … 65 °C
Damage to the environment.
• Dispose of the device and packaging in an environmen-
tally friendly manner.
• Observe applicable regulations on disposal and the
environment.
English
Loading...
+ 10 hidden pages