Table of Contents
Type 7615
Micro dosing unit Type 7615
1 OPERATING INSTRUCTIONS ................................................................4
1.1 Symbols .......................................................................................4
1.2 Definition of the term "Device" ...............................................4
2 AUTHORIZED USE ......................................................................................5
2.1 Restrictions .................................................................................5
3 BASIC SAFETY INSTRUCTIONS ..........................................................5
4 GENERAL INFORMATION ........................................................................7
4.1 Contact addresses ...................................................................7
4.2 Warranty ......................................................................................7
4.3 Information on the Internet ......................................................7
5 SYSTEM DESCRIPTION ............................................................................7
5.1 Conformity ................................................................................... 7
6 TECHNICAL DATA ........................................................................................8
6.1 Operating conditions ................................................................ 8
6.2 General technical data ............................................................. 8
7 INSTALLATION
7.1 Safety instructions ..................................................................... 9
7.2 Preparatory work .......................................................................9
7.3 Fluid connections ...................................................................... 9
7.4 Installation .................................................................................10
7.5 Electrical connection ..............................................................10
...............................................................................................9
8 START-UP
8.1 Safety instructions ...................................................................11
8.2 Control diagram .......................................................................11
8.3 Dosing quantity ........................................................................12
8.4 Selecting the dosing mode ...................................................12
8.5 Selecting the operating mode / pin assignment ..............13
9 MALFUNCTIONS
10 ACCESSORIES
11 PACKAGING, TRANSPORT, STORAGE ..........................................14
12 DISPOSAL
...................................................................................................... 11
........................................................................................14
........................................................................................... 14
..................................................................................................... 14

english

3
3
Type 7615
Operating instructions
1 OPERATING INSTRUCTIONS
The operating instructions describe the entire life cycle of the device. Keep these instructions in a location which is easily accessible to every user and make these instructions available to every new owner of the device.
The operating instructions contain important safety information!
Failure to observe these instructions may result in hazardous situations.
▶ The operating instructions must be read and understood.
1.1 Symbols
DANGER!
Warns of an immediate danger!
▶ Failure to observe the warning will result in a fatal or serious
injury.
WARNING!
Warns of a potentially dangerous situation!
▶ Failure to observe the warning may result in serious injuries or
death.
CAUTION!
Warns of a possible danger!
▶ Failure to observe this warning may result in a moderate or
minor injury.
NOTE!
Warns of damage to property!
▶ Failure to observe the warning may result in damage to the
device or the equipment.
Indicates important additional information, tips and recommendations.
Refers to information in these operating instructions or in other documentation.
→ Designates a procedure which you must carry out.
1.2 Definition of the term "Device"
In these instructions, the term "device" always refers to the micro dosing unit Type 7615.
4
english
Type 7615
Authorized use
2 AUTHORIZED USE
Non-authorized use of the micro dosing unit Type 7615 may represent a hazard to people, nearby equipment and the environment.
▶ The device is designed for the dosing of small fluid or gas quan-
tities. It must only be used for the media listed in the chapter “6 Technical data”.
▶ Prior to the use of aggressive media, the resistance of the
media-wetted materials must be checked. Information on the resistance of materials to the media is available from your
Bürkert sales office or on the Internet: www.buerkert.de ▶ Do not use the device outdoors without appropriate housing. ▶ Use according to the authorized data, operating conditions,
and conditions of use specified in the contract documents and
operating instructions. These are described in the chapters
“5 System description” and “6 Technical data”. ▶ The device must only be used in conjunction with third-party
devices and components recommended and authorized by
Bürkert. ▶ Correct transportation, storage, and installation, as well as care-
ful use and maintenance are essential for reliable and faultless
operation.
• The micro dosing unit must not be used in potentially explosive areas.
• Do not operate the device without suitable filtration of the input medium.
• Use the device only as intended.
2.1 Restrictions
If exporting the system/device, observe any existing restrictions.
3 BASIC SAFETY
INSTRUCTIONS
These safety instructions do not make allowance for any
• Contingencies and events which may arise during the installation, operation, and maintenance of the devices.
• Local safety regulations – the operator is responsible for observing these regulations, also in relation to the installation personnel.
The micro dosing unit Type 7615 was developed with due consideration of the accepted safety rules and is state-of-the­art. Nevertheless, dangerous situations can occur.
english
5
Type 7615
Authorized use
DANGER!
Danger – high pressure!
▶ Before disconnecting any lines and valves, turn off the pressure
and vent the lines.
Risk of electric shock!
▶ Before reaching into the device or equipment, switch off the power
supply and secure to prevent reactivation!
▶ Observe applicable accident prevention and safety regulations
for electrical equipment!
CAUTION!
Risk of burns/risk of fire if used continuously through hot device surface!
▶ Keep the device away from highly flammable substances and
media and do not touch with bare hands.
General hazardous situations.
To prevent injury, ensure the following:
▶ Ensure that the system cannot be activated unintentionally.
• Do not place a physical load on the housing (e.g. by placing objects on it or standing on it).
• Do not make any external alterations to the housing of the device. Do not paint housing parts or screws.
▶ Installation and repair work may be carried out by authorized
technicians only and with the appropriate tools.
▶ After an interruption in the electrical or pneumatic supply,
ensure that the process is restarted in a defined or controlled manner.
▶ The device must only be operated when in a perfect condition
and in consideration of the operating instructions.
▶ The general rules of technology must be observed for applica-
tion planning and operation of the device.
NOTE!
Electrostatic sensitive components/modules!
• The device contains electronic components which react sensitively to electrostatic discharge (ESD). Contact with electrostatically charged persons or objects are hazardous to these components. In the worst case scenario, they will be destroyed immediately or will fail after start-up.
• Observe the requirements in accordance with DIN EN 61340-5-1/5-2 to minimize or avoid the possibility of damage caused by sudden electrostatic discharge!
• Also, ensure that you do not touch electronic components when the power supply voltage is present!
6
english
Type 7615
General information
4 GENERAL INFORMATION
4.1 Contact addresses
Germany
Bürkert Fluid Control Systems Sales Center Chr.-Bürkert-Str. 13–17 74653 Ingelfingen Germany Tel.: +49 (0) 7940 - 10 91 111 Fax: +49 (0) 7940 - 10 91 448 E-mail: info@de.buerkert.com
International
Contact addresses can be found on the final pages of the printed operating instructions.
And also on the Internet at: www.burkert.com
4.2 Warranty
The warranty is only valid if the device is used as intended in accordance with the specified application conditions.
4.3 Information on the Internet
The operating instructions and data sheets for Type 7615 can be found on the Internet at: www.burkert.com
5 SYSTEM DESCRIPTION
Due to the high reproducibility, the unit, which operates according to the diaphragm pump principle, is suitable for the precise dosing of very small fluid quantities in the µl range.
The dosing unit can also be used for aggressive media as high­quality materials are used for the parts that come in contact with the media.
The structure of the unit with active inlet and discharge valves enables a bidirectional supply. The electronic control systems are integrated in the unit.
The supply rate of the dosing unit is dependent on the viscosity of the supplied medium and the flow resistances up- and downstream of the dosing unit (e.g. hose system).
5.1 Conformity
The micro dosing unit Type 7615 conforms to the EC directives according to the EC Declaration of Conformity.
english
7
7615 CC PK
00202784
english
Type 7615
Technical data
6 TECHNICAL DATA
6.1 Operating conditions
WARNING!
Burns, chemical burns through leaking medium.
▶ Prior to the use of aggressive media, the resistance of the
media-wetted parts must be checked.
You can access the Bürkert Chemical Resistance Chart on the Internet at www.buerkert.de
Chemical Resistance Chart. If you are unsure, please contact your Bürkert Sales Center.
NOTE!
Malfunction!
▶ Do not use Type 7615 outdoors without the appropriate hous-
ing and avoid heat sources that may cause the permissible temperature range to be exceeded.
Permitted temperatures
Ambient temperature: +10 to +55°C
Medium temperature: +15 to +60°C (FFKM seals) + 5 to +60°C (EPDM seals)
Media: Neutral and aggressive liquid media. Check suitability
according to the Chemical Resistance Chart.
Protection class: IP40
Documentation
Brochures
6.2 General technical data
Observe the technical specifications as detailed on the type plate!
Max. manometric pressure: approx. 1 bar (overpressure towards the atmospheric pressure) Dosing quantity: 5 µl/stroke
Connections: 4-pole Molex connector (Molex no. 50-57-9404)
6.2.1 Rating plate
Example:
Type
24V DC DOSING UNIT
S/N 1050
Made in Germany
Fig. 1: Rating plate description
11W
Voltage / type of current
Seal material
Housing material
W16LP
Power
Device designation Serial number
Date of manufacture (encoded)
Identification number of the device
8
english
Type 7615
Installation
7 INSTALLATION
7.1 Safety instructions
CAUTION!
Risk of injury from improper installation!
▶ Installation must only be carried out by authorized technicians
and with the appropriate tools!
▶ Before disconnecting any lines and valves, turn off the pressure
and vent the lines.
▶ Before reaching into the device or equipment, switch off the
power supply and secure to prevent reactivation!
▶ Observe applicable accident prevention and safety regulations
for electrical equipment!
7.2 Preparatory work
→ Clean the connection lines
NOTE!
Malfunction due to unfiltered medium!
Crystallized medium or particles in the medium impair the func­tionality of the device or result in the unit being destroyed.
→ Install the upstream filter.
(Pore size: 50 µm)
7.3 Fluid connections
WARNING!
Burns, chemical burns through leaking medium.
▶ Prior to the use of aggressive media, the resistance of the
media-wetted parts must be checked.
You can access the Bürkert Chemical Resistance Chart on the Internet at www.buerkert.de
Chemical Resistance Chart. If you are unsure, please contact your Bürkert Sales Center.
The unit can be supplied as a flanged version and designed with connecting thread UNF ¼-28. Arrows indicating the standard flow direction are located on the fluid connection plates (flange and UNF ¼-28). The flow direction can be changed by altering the power supply (refer to “8.5 Selecting the operating mode / pin assignment”).
Flanged version Design with connecting
Documentation
thread UNF ¼-28
Brochures
Fig. 2: Illustration of the different versions
9
M
3
Flanschbild für Anschlußplatte
Type 7615
Installation
→ Mount the hose connection as shown in the illustration.
Hose
Fitting
Ferrule
Fig. 3: Structure UNF ¼ - 28 for fluid connection
7.4 Installation
Any installation position
→ Screw the device into place.
Use the respective bores for the M3 screws (see “Fig. 4: Installation”).
Flanged design: Design with connection
thread UNF ¼-28:
min. t=6
7
Fig. 4: Installation
max. ø2,5
11,8 34,5
M 3
20.5
7.5 Electrical connection
Note the voltage as specified on the rating plate!
→ Connect the device electrically.
See chapter “8.5 Selecting the operating mode / pin assignment”, page 13.
10
english
V2
V3
Type 7615
Start-up
8 START-UP
8.1 Safety instructions
WARNING!
Risk of injury from improper operation!
Improper operation may result in injuries as well as damage to the device and the area around it.
▶ Before start-up, ensure that the operating personnel are familiar
with and completely understand the contents of the operating instructions.
▶ The safety instructions and “2 Authorized use” must be
observed.
▶ Only adequately trained personnel may start up the equipment/
device.
8.2 Control diagram
V1
T0 T5T4T3T2T1 T6
Fig. 5: Control diagram
V1 = inlet valve V2 = dosing valve V3 = discharge valve The optional control times are saved in the dosing unit software and
cannot be changed.
T1
english
11
Type 7615
Start-up
8.3 Dosing quantity
The dosing unit is set to a pumping volume of 5µl/pump stroke as standard. This value cannot be changed.
8.4 Selecting the dosing mode
By default, the dosing unit is configured so that it doses at a fre­quency of 5 Hz once the power supply voltage is connected. The dosing mode can be pre-selected on the rotary switch for the elec­tronics once the cover has been removed (see “Fig. 6: Setting the dosing mode”).
DANGER!
Risk of electric shock!
▶ Before reaching into the device or equipment, switch off the power
supply and secure to prevent reactivation!
▶ Only adequately trained personnel may reach into the device!
Rotary switch for pre-selecting the
dosing mode
Making adjustments using the rotary switch for the electronics:
0 Impulse mode
>120 ms
1 40 Hz frequency mode Unit is in frequency mode and 2 25 Hz frequency mode 3 10 Hz frequency mode
5 Hz frequency mode
4
(standard)
5 5 Hz service mode;
unit stops after 100 cycles
Unit doses precisely 5 µl (= 1 stroke) and then stops. Power supply voltage must be at least 120 ms for this purpose. If the power supply is then interrupted for > 2 ms and is subsequently reconnected, a stroke is initiated, etc.