Burkert 6227 User Manual [en, de, fr]

Type 6227
Modular Combinable Water Valve Modular anreihenbares Wasserventil Vanne à eau modulaire rangée
Operating Instructions
Bedienungsanleitung Manuel d‘utilisation
We reserve the right to make technical changes without notice. Technische Änderungen vorbehalten. Sous réserve de modifications techniques.
© 2002 – 2013 Bürkert Werke GmbH
Operating Instructions 1301/08_EU-ML_00801165 / Original DE
CONTENTS:
1 GENERAL SAFETY INSTRUCTIONS 2
2 GENERAL DESCRIPTION 2
2.1 Construction of the valve 3
2.2 Diagram of the modular combinable water valve 3
2.3 Medium 4
3 INSTALLATION AND COMMISSIONING 4
3.1 Installation 4
3.3 Measures to be taken before installation 5
3.2 Electrical connection 5
4FAULTS 6
english
SYMBOLS USED
In these Operating Instructions, the following symbols are used:
Indicates a work step which you must carry out.
ATTENTION!
NOTE
Indicates information which must be followed. Failure to do this could endanger your health or the functionality of the device.
Indicates important additional information, tips and recommendations.
6227 - 1
1 GENERAL SAFETY INSTRUCTIONS
To ensure that the device functions correctly, and will have a long service life, please comply with the information in these Operating Instructions, as well as the application conditions and additional data given in the Type 6227 data sheet:
• When planning the application of the device, and during its operation, observe the general technical rules!
• Work on the device should only be carried out by specialist staff using suitable tools!
english
• Please note: Piping or valves should not be removed from a system which is under pressure!
• Always switch off the voltage supply before working on the system!
• Take suitable measures to prevent unintentional operation or impermissible impairment.
• If these instructions are ignored, or if inadmissible work is carried out on the device, no liability will be accepted from our side, and the guarantee on the device and accessory parts will become invalid!
ATTENTION!
Danger of injury! The surface of the solenoid valve can become very hot during continuous operation.
2 GENERAL DESCRIPTION
2.1 Construction of the valve
Modular, combinable valve system of 2/2-way solenoid valves, which work as pilot-controlled diaphragm seat valves.
Available in nominal widths: DN10 and DN13
Operation: WWA, i.e. closed when off
2 - 6227
2.2 Diagram of the modular combinable water valve
Mounting
module, right
DN 13 base module dual
Valve set type 6227
DN 13
DN 10 insert
(fitted with manifold or distributor
function depending on the installation
position)
DN 13 insert
(fitted with manifold or distributor
function depending on the installation
position)
Sensor holder
or triple
Mounting plate 1/2" or 3/4"
internal thread
Terminating module
english
Valve set type 6227
DN 10
Mounting plate 1/2" or 3/4"
Mounting
module, left
internal thread
DN 10 base module dual,
triple or quad
Terminating
module
Hose connection
3/8" internal thread
Lower connections:
6227 - 3
3/4" outer thread with
check valve
3/4" outer thread
2.3 Medium
Neutral liquids, in particular water and water containing additives, which do not attack the housing and the sealing material.
Sealing material: NBR Housing material: PA Minimum pressure difference for complete opening of the valve: 1 bar
ATTENTION!
english
Continual pressure surges can shorten the service life of the diaphragm!
3 INSTALLATION AND COMMISSIONING
3.1 Installation
Î Before installing the valve, clean the piping system!
Î Where necessary, fit a strainer upstream to protect against faults!
Î Observe the direction of flow!
Î Seal the thread using PTFE tape.
Î When installing the valve, ensure that the valve block is not distorted:
- provide adequate support for the piping system
- align the piping system
Maximum permissible torque Mt: for G 3/4" connections from plastic: 4 Nm
Maximum permissible bending moment MB: for all connections: 6 Nm
M
M
B
t
ATTENTION!
4 - 6227
Do not use the pilot valve as a lever when screwing in the pipe connection!
Do not distort the valve housing during the installation!
Max. ambient temperature for continuous operation: +55 °C!
3.2 Electrical connection
• The voltage, electrical power, pressure range and nominal width can be found on the name plate.
• Voltage tolerance: ± 10%
• Electrical connection: Instrument socket Type 2508 to the connection plug pin of the coil; Fixing torque: 0.5 Nm
ATTENTION!
Î Ensure that the maximum operating conditions (see
name plate) are not exceeded!
Î Always connect the protective conductor!
Î Always follow the warning instructions on the coil,
particularly for coils which require rectifiers!
Î When screwing the coil and the instrument socket
together, ensure that the seal is properly seated!
3.3 Measures to be taken before installation
Î Before the installation, check:
- fluid and electrical connections
- Operational pressure
- Voltages
- Type of current.
english
6227 - 5