580J***(D,F)
SINGLE PACKAGE ROOFTOP
GAS HEATING/ELECTRIC COOLING UNIT
TWO ST AGE COOLING CAPACITY CONTROL WITH NOVATIONt COIL
SIZES 08, 12, 14 WITH PURONR (R--410A) REFRIGERANT
Submittal Data
DESCRIPTION
®
This product has been designed and manufac tured
to meet Energy S tar® criteria for energy efficiency.
However, proper refri gerant charge and proper ai r
flow are crit ical to achi eve rated capacity and ef ficiency. Installation of this product should follow all
manufacturer’s refrigerant charging and air flow instructi ons. Failure to confirm proper charge and
air flow may reduc e en ergy eff i ciency and shorten equipment life.
580J***(D,F) units are high--efficiency, single--pac kaged
electric cooling, gas heating units that are pre--wired and
pre--charged with PuronR (R--410A) HFC refrigerant.
Units utilize an all aluminum flat micro--channel tube
with louvered fins condenser coil—NOVATIONt.The
units are factory tested in both heating and cooling modes.
These units meet the ASHRAE 90.1--2007 and Energy
Star minimum efficiency levels as well as also meeting
2010 efficiency standards.
STANDARD FEATURES
Base Unit
S Puron (R--410A) HFC refrigerant
S ARI certified efficiency levels up to 11.1 EER
S Rated in accordance with ARI Standard 360
S Designed in accordance with Underwriters’ Laboratories Std
1995 and listed by UL and UL, Canada
S Two--stage cooling capacity control
S Non --corrosive composite sloping design; side or center drain
condensate pan. Meets ASHRAE Standard 62
S Standard cooling operating range from 40_Fupto115_F
(4_Cupto46_C). Field installable accessory extends the
minimum down to --20_F(--29_C).
S Convertible from vertical to horizontal airflow for slab mounting
S Two--inch disposable return air filters
S Thru--the--bottom power and gas entry capability
S Single point gas and electric connections
S 24 --volt control circuit protected with resettable circuit breaker
and 75--VA transformer
S Belt drive, constant torque, permanently lubricated
evaporator–fan motor
S Totally enclosed condenser motors with permanently lubricated
bearings
S Low--pressure and high--pressure switches
S Full perimeter base rail with built--in rigging adapters and fork
truck slots
S Centralized Terminal Board for component and unit wiring
connections
Cabinet
S Access panels with easy grip handles and NO--STRIP screw
collar
S Pre--painted exterior panels and primer--coated interior panels
tested to 500 hours salt spray protection
S Fully insulated cabinet
S Tool--less filter access door
Refrigerant System
S Acutrolt refrigerant metering system
S Liquid line filter drier
S Scroll compressors with internal line--break overload protection
S Copper
S NOVATION all aluminum condenser coil
S Removable gauge line plugs for reading refrigerant pressure
tube, aluminum fin evaporator coil
with unit panels in place
Gas Heat
S IGC solid--state gas heat exchanger control for on-- board
diagnostics, anti--cycle protection, LED error code designation,
burner control logic and energy saving indoor fan motor delay
S Gas efficiencies up to 82%
S Designed in accordance with ANSI Z21.47 (design and test
standard for gas furnaces) and ANSI Z233.1 (National Fuel Gas
code relating to appliance installation requirements)
S Induced draft combustion
S Redundant gas valve, with up to 2 stages of heating
S Flame roll--out safety protector
S Solid--state electronic direct spark ignition system
Standard Warranty
S 15--year gas heat exchanger -- Stainless Steel
S 10--year gas heat exchanger -- Aluminized
S 5--year compressor
S 3 --year NOVATION condenser coil
S 1--year parts
580J***(D,F)
STANDARD FEATURES (cont.)
SUBMITTAL DATA
Job Na m e
Architect
Engineer
Contractor
Unit Designation
PERFORMANCE DATA
Unit Operating Weight lb
Cooling
Gross Total Capacity: Btuh
at Condenser Air Temperature _F
Gross Sensible Capacity: Btuh
Compressor Power Input: kW
Indoor Entering db _Fwb _F
Airflow External Static Pressure in.wg
Indoor Fan Motor Size Hp
Exhaust Fan Motor Size Hp
Curb Weight lb
Heating
Heating Capacity:
Stage 1 Btuh
Stage 2 Btuh
Heating Capacity Total Btuh
Stage 1 kW
Stage 2 kW
Heating Capacity Total kW
ELECTRICAL DATA
Power Supply to Unit Volts Phase Hz
Minimum Circuit Amps Maximum Overcurrent Protection
2
OPTIONS AND ACCESSORIES
FACTORY--INSTALLED OPTIONS (FIOPs)
j Open protocol RTU--MP controller communicates to
LON, MODBUS, BACNET and Johnson N2 protocols.
j Through the base connectors for gas and electric
conduit/piping
j Stainless steel gas heat exchanger (includes tubes,
vestibule plate and collector box)
j Economizer with dry bulb sensing and barometric
relief
j Economizer with enthalpy sensing and barometric
relief
j 2 position motorized outdoor air damper
j Non--fused disconnect
j Powered 115--volt convenience outlet
j Non--powered 115--volt convenience outlet
j High static evaporator fan motor
j Return Air smoke detector
j Supply Air smoke detector
j CO
j Condenser hail guard -- louvered style
sensor
2
OPTIONAL WARRANTIES
j Complete Unit Parts only up to 5 years
j Complete Unit Parts and Labor up to 5 years
Many other optional warranties are available.
See the Commercial Start--Up and Optional Extended
Warranty Price price pages for further information.
FIELD INSTALLED ACCESSORIES
j Economi$ert IV--electromechanical, gear driven with
Belimo actuator (2--10v DC signal) and controller
j Economi$ert2-- compatible with DDC controls; gear
driven with Belimo actuator (4--20mA) signal and
no controller
j Power e xhaust
j Two--position motorized outdoor air damper
j Manual outdoor air damper 25%
j Manual outdoor air damper 50%
j Roofcurb -- 14 inch (356mm) tall
j Roofcurb -- 24 inch (610mm) tall
j Thru--the--bottom connections--electrical only
j Thru--the--bottom connections--electrical and gas
j Condenser hail guard -- louvered style
j Flue shield
j Flue discharge deflector
j Liquid propane (LP) conversion kit
j High altitude conversion kit
j Phase monitor (loss of phase/phase reversal)
j Winter start kit, down to 25_F(--4_C)
j Low ambient head pressure controller,
downto0_F(--18_C)
j Low ambient head pressure controller,
down to --20_F(--29_C)
j Time Guard II compressor anti--cycle protection
Economizer Sensors
j Single Dry bulb control
j Differential Dry bulb control
j Single enthalpy control
j Differential enthalpy control
j CO
j CO
j CO
-- wall mounted
2
-- duct mounted
2
-- unit mounted
2
580J***(D,F)
3