Broan QS342SS User Manual

ALLURE® QS3 SERIES
!
!
!
RANGE HOOD
ALLURE
®
QS3 SERIES RANGE HOOD
READ AND SAVE THESE INSTRUCTIONS
FOR DOMESTIC COOKING ONLY
WARNING
1. Use this unit only in the manner intended by the manufacturer. If you have questions, contact the manufacturer at the address or telephone number listed in the warranty.
2. Before servicing or cleaning unit, switch power off at service panel and lock the service disconnecting means to prevent power from being switched on accidentally. When the service disconnecting means cannot be locked, securely fasten a prominent warning device, such as a tag, to the service panel.
3. Installation work and electrical wiring must be done by a qualified person(s) in accordance with all applicable codes and standards, includ­ing fire-rated construction codes and standards.
4. Sufficient air is needed for proper combustion and exhausting of gases through the flue (chimney) of fuel burning equipment to prevent backdraft­ing. Follow the heating equipment manufacturer’s guideline and safety standards such as those published by the National Fire Protection As­sociation (NFPA), and the American Society of Heating, Refrigeration and Air Conditioning Engineers (ASHRAE), and the local code authorities.
5. When cutting or drilling into wall or ceiling, do not damage electrical wiring and other hidden utilities.
6. To reduce the risk of fire or electric shock, do not use this range hood with an additional speed control device.
7. Ducted fans must always be vented to the outdoors.
8. To reduce the risk of fire, use only metal ductwork.
9. Use with approved cord-connection kit only.
10. This unit must be grounded.
TO REDUCE THE RISK OF A RANGE TOP GREASE FIRE:
1. Never leave surface units unattended at high settings. Boilovers cause smoking and greasy spillovers that may ignite. Heat oils slowly on low or medium settings.
2. Always turn hood ON when cooking at high heat or when cooking flaming foods.
3. Clean ventilating fans frequently. Grease should not be allowed to accumulate on fan or filter.
4. Use proper pan size. Always use cookware appropriate for the size of the surface element.
TO REDUCE THE RISK OF INJURY TO PERSONS IN THE EVENT OF A RANGE TOP GREASE FIRE, OBSERVE THE FOLLOWING:*
1. SMOTHER FLAMES with a close-fitting lid, cookie sheet, or metal tray, then turn off the burner. BE CAREFUL TO PREVENT BURNS. If the flames do not go out immediately, EVACUATE AND CALL THE FIRE DEPARTMENT.
2. NEVER PICK UP A FLAMING PAN — You may be burned.
3. DO NOT USE WATER, including wet dishcloths or towels - violent steam explosion will result.
4. Use an extinguisher ONLY if: A. You know you have a Class ABC extinguisher and you already know
how to operate it. B. The fire is small and contained in the area where it started. C. The fire department is being called. D. You can fight the fire with your back to an exit. * Based on “Kitchen Fire Safety Tips” published by NFPA.
Page 1
Patent No.: US D450, 829 S
CAUTION
1. For general ventilating use only. Do not use to exhaust hazardous or explosive materials and vapors.
2. To avoid motor bearing damage and noisy and/or unbalanced impellers, keep drywall spray, construction dust, etc. off power unit.
3. For best capture of cooking impurities, your range hood should be mounted so that the top of the hood is 24-30” above the cooking surface.
4. Please read specification label on product for further information and requirements.
Installer: Leave this manual with the homeowner.
Homeowner: Operating and Cleaning information on page 6.
NOTE If hood is to be installed Non-Ducted: Purchase a set of (2) non-ducted filters from your
local distributor or retailer and attach them to the aluminum mesh filters.
TABLE OF CONTENTS
This manual is divided into sections as follows:
“PREPARE HOOD LOCATION”
Run ductwork from roof or wall cap, and electrical wiring from service
panel - to installation location
“PREPARE THE HOOD” Get your hood ready for installation
“CONNECT WIRING”
Make electrical wiring connections to hood
“INSTALL HOOD” Secure hood to cabinet and ductwork - install bulbs and filters
“OPERATION” How to use the hood controls
“CLEANING” Keep your hood in top working condition
“SERVICE PARTS”
Part numbers and exploded view of hood components
“WARRANTY” One-year limited warranty and how to contact us
ALLURE® QS3 SERIES
CABINET BOTTOM
CABINET FRONT
HORIZONTAL DUCT
ACCESS HOLE
5¼"
5¼"
7½"
1
/
8
"
¾"
13
15
/
16
"
(30" hood)
16
15
/
16
"
(36" hood)
13
15
/
16
"
(30" hood)
HOOD
MOUNTING
SCREWS (4)
ELECTRICAL
ACCESS HOLE
(in wall)
3¾"
16
15
/
16
"
(36" hood)
CENTER
LINE
WOOD SHIMS
(recessed-bottom
cabinets only)
19
15
/
16
"
(42" hood)
19
15
/
16
"
(42" hood)
SOFFIT
24" - 30" ABOVE COOKING SURFACE
CABINET
3¼" X 10" DUCT (For horizontal discharge)
WALL CAP
ROOF CAP
3¼" X 10" or
7" ROUND DUCT
(For vertical
discharge)
HOUSE WIRING (Top or Back of hood)
HOODHOOD
VERTICAL DUCT
ACCESS HOLE
1¼"
1½"
10½"
5¼"
5¼"
CENTER
LINE
HOOD MOUNTING SCREWS (4)
ELECTRICAL
ACCESS HOLE
(in cabinet bottom)
WOOD SHIMS
(recessed-bottom
cabinets only)
CABINET FRONT
CABINET BOTTOM
13
15
/
16
"
(30" hood)
16
15
/
16
"
(36" hood)
7½"
5"
2"
19
15
/
16
"
(42" hood)
13
15
/
16
"
(30" hood)
16
15
/
16
"
(36" hood)
19
15
/
16
"
(42" hood)
RANGE HOOD
Page 2
PREPARE HOOD LOCATION
1 Determine whether hood will discharge vertically (3¼” x 10”
or 7” Round), or horizontally (3¼” x 10” only). For vertical or horizontal discharge, run ductwork between the hood location and a roof cap or wall cap. For best results, use a minimum number of transitons and elbows.
2 Use diagrams, below, for proper placement of ductwork and
electrical cutout in cabinet or wall. For a non-ducted installa­tion, DO NOT cut a duct access hole.
3¼” X 10”
VERTICAL DUCTING
PREPARE HOOD LOCATION
7” ROUND
VERTICAL DUCTING
3 Run house wiring between service panel and hood location.
PREPARE THE HOOD
7” ROUND
DUCT PLATE
3¼” X 10”
HORIZONTAL DUCTING
1 Remove 7” Round Duct Plate from top of hood. Set duct
plate aside - with mounting screws.
FILTERS
2 Remove tape holding Filters in place. Pull down on filter
tabs or finger holes and lift filters out. Set filters aside.
ALLURE® QS3 SERIES
RANGE HOOD
Page 3
PREPARE THE HOOD
3 Remove
Teflon®-coated bottom cover
from hood. Set cover and mounting screws aside.
Teflon® is a registered trademark of DuPont.
TEFLON®-COATED BOTTOM COVER
(Held in place with 2 screws)
4 Remove
Damper/Duct Connector
from inside the hood. Set connector aside - with mounting screws and parts bag.
DAMPER/
DUCT
CONNECTOR
5 Remove either
top or back wiring knock­out and install approved
Electrical Cable Clamp.
PREPARE THE HOOD
AIR CHUTE
7 Remove Air
Chute - held in place with one (1) screw.
NOTE: Be care-
ful not to discon­nect any wires.
8 Remove Baffle
from air chute.
BAFFLE
BAFFLE
ELECTRICAL CABLE CLAMP
Non-Ducted Installation - Skip to Step 15.
(3) #8 SCREWS
The following Steps (6 thru
14) are for
(2) #8 SCREWS
DUCTED INSTALLATION ONLY.
6 Remove Light Panel - held in place with (3) #8 screws
and (2) #8 screws. Disconnect light assembly wire harness (white connector).
LIGHT
PANEL
9 Rotate baffle. Re-
insert baffle into air chute (as shown) so that baffle tabs fit all the way into slots in air chute. An audible “click” will be heard when fully installed. This will close off the air flow through the non-ducted slots on top of hood.
10
Re-install air chute, re-connect wire
harness, and replace light panel.
NOTE: Be careful not to trap wires
between support fin and light panel.
SLOTS
TABS
SUPPORT FIN
ALLURE® QS3 SERIES
RANGE HOOD
Page 4
PREPARE THE HOOD
TOP RECTANGULAR
DUCT KNOCKOUT
(Remove for 3¼” x 10”
Vertical & for 7” Round
Discharge)
REAR
RECTANGULAR
DUCT KNOCKOUT
(Remove for 3¼” x 10” Horizontal Discharge)
11 Remove appropriate Duct Knockout(s) from top or back of
hood.
SCREW
TIES
SEMI-CIRCULAR
DUCT KNOCKOUT
(Remove for 7” Round
Discharge)
PREPARE THE HOOD
UP TO 1” SIDE-TO-SIDE ADJUSTMENT
PIVOT
13 3¼” x 10” Ducted Discharge Only: Remove Tape from damper
flap and attach Damper/Duct Connector over knockout opening with screws removed in Step 4 under “PREPARE THE HOOD”. Make sure damper Pivot is nearest to Top/Back Edge of hood.
14 7” Round Ducted Discharge Only: Re-install 7” Round Duct
Plate removed in Step #1 under “PREPARE THE HOOD”. Install a 7” round damper (purchase separately). Damper flap must open freely in direction of airflow (away from range hood).
NOTE
up to ½” on either side of hood center. In extreme off-center installations, one end of the duct connector may need to be trimmed to clear the electrical cable clamp.
To accomodate off-center ductwork, the Damper/Duct Connector can be installed up to 1-inch on either side of hood center or the 7” Round Duct Plate can be installed
TAPE
TOP/BACK
EDGE
DAMPER/
DUCT
CONNECTOR
(Vertical
discharge
position shown)
METAL STRIP
12 Horizontal Discharge Only: Remove the Plate in front of the
horizontal discharge knockout. Cut the Ties, lift plate out, and discard plate. DO NOT REMOVE the Metal Strip held in place with two Screws.
PLATE
RETAINING
RING
15 Non-Ducted Installations Only: Require a Performance Ring
to be attached to the blower wheel.
To install ring:
1. Remove the Blower Wheel by rocking it side to side and applying a slight force to pull wheel from motor. Remove Retaining Ring if necessary.
2. Slide the ring onto the Small Diameter End of the wheel and down to the Stop Edge of the wheel.
3. Reassemble wheel to motor. Make sure Tab on wheel fits into one of the Motor Slots.
4. Push wheel down until it is locked in place.
5. Check that wheel is properly positioned as shown. Press Sections into place if necessary. Make sure wheel turns freely.
BLOWER
WHEEL
SECTIONS
TAB
MOTOR
SLOTS
SMALL DIAMETER
END
RING
STOP
EDGE
ALLURE® QS3 SERIES
!
RANGE HOOD
Page 5
CONNECT WIRING
WARNING: To reduce the risk of electric shock, make sure power is switched off at the service panel. Lock or tag service panel to prevent power from being switched on accidentally.
HOUSE
WIRING
(120 VAC)
CARDBOARD
(Use to protect
cooktop)
1 Connect House Wiring (120 VAC) to hood. Use a piece of
Cardboard to protect the cooktop, if necessary.
INSTALL HOOD
KEYHOLE (4)
1 Hang hood from (4) Mounting Screws. Slide hood towards
wall until mounting screws are engaged in narrow end of (4) Keyholes. Tighten mounting screws securely. A long screwdriver works best.
2 Replace bottom cover.
MOUNTING SCREW (4)
DUCT
TAPE
GREEN
GROUND
SCREW
2 Connect house black to hood black wire, house white to hood
white wire, and house ground under Green Ground Screw. Securely tighten cable clamp onto house wiring.
3 Connect ductwork to hood. Use Duct Tape to make joints
secure and air tight.
PAR20, 50W MAX. HALOGEN
BULB (2)
- or ­R16,
40W MAX.
INCANDESCENT
BULB (2)
4 Install (2) PAR20, 50 W Maximum Halogen Bulbs or (2)
R16, 40 W Maximum Incandescent Bulbs. Purchase bulbs separately.
CAUTION: Bulbs may be hot! Refer to bulb packaging
for further information.
5 Replace filters, turn on power at service panel, and test for
proper operation.
Loading...