Broan P8, P5 Specifications

Model P5 Blower Rough-in
Kit
500 cfm, 120 VAC, 1.8
Amps Interior-mounted, single-
wheel design Attaches to rough-in plate
independent of hood Includes rough-in kit, with
flow-deviator and damper adaptor
Uses 3¼” x 10” rectangular
or 8” round duct
Model P8 Blower Rough-in
Kit
850 cfm, 120 VAC, 3.4
Amps Interior-mounted, single-
wheel design Attaches to rough-in plate
independent of hood Includes rough-in kit, with
flow-deviator and damper adaptor
Uses 3¼” x 14” rectangular
or 8” round duct
Model 634 Roof Cap
24 GA. CRCQ steel,
black electrically­bonded epoxy finish
Built-in backdraft
damper and bird screen
For 3¼” x 10” or up
to 8” round duct
Model 644 Roof Cap
Same as Model 634
except .025 aluminum Natural finish
Best by Broan, P.O Box 140, Hartford, Wisconsin 53027
Model 412 3¼” x 10” to 7” Round Adjustable Elbow
Model 413 3¼” x 10” to 8” Round Adjustable Elbow
Model T460 3¼” x 14” to 7” Round Transition
Model 459 3¼” x 14” to 8” Round Transition
Model WC638 Wall Cap
SPECIFICATION SHEET
For use with
Best by Broan
K210A, PIK33, & PIK45
Series Range Hoods
For 3¼” x 14” duct Spring-loaded
backdraft damper and bird screen
26 GA. CRCQ steel, black finish
REFERENCE QTY. REMARKS Project
Location Architect Engineer Contractor Submitted By Date
70D 99042720C
PERFORMANCE RATINGS
For use with Best by Broan K210A, PIK33, & PIK45 Series Range Hoods
P5 (Horizontal)
1.20
1.00
0.80
0.60
0.40
Static Pressure (in-wg)
0.20
0.00
0 100 200 300 400 500 600
Air Flow R ate (c fm)
P8 (Horizontal)
1.40
1.20
1.00
0.80
0.60
P5
(Vertical)
1.20
1.00
0.80
0.60
0.40
Static Pressure (in-wg)
0.20
0.00
0 50 100 150 200 250 300 350 400 450 500
Air Flow Rate (cfm)
P8
(Vertical)
1.40
1.20
1.00
0.80
0.60
0.40
Static Pressure (in-wg)
0.20
0.00
0 100 200 300 400 500 600 700 800 900 1000
Air Flow R ate (c fm)
0.40
Static Pressure (in-wg)
0.20
0.00
0 100 200 300 400 500 600 700 800 900 1000
Air Flow Rate (cfm)
HVI-2100 CERTIFIED RATINGS comply with new testing technologies and procedures prescribed by the Home Ventilating Institute, for off-the-shelf products, as they are available to consumers. Product performance is rated at 0.1 in. static pressure, based on tests conducted in AMCA’s state-of-the-art test laboratory. Sones are a measure of humanly-perceived loudness, based on laboratory measurements.