For use with compatible Best by Broan range hoods.
See hood manual for suitability.
WARNING
TO REDUCE THE RISK OF FIRE, ELECTRIC SHOCK, OR INJURY TO PERSON(S) OBSER VE THE FOLLOWING:
1. Use this unit only in the manner intended by the manufacturer. If you have questions, contact the manufacturer at the
address or telephone number listed in the warranty.
2. Before servicing or cleaning unit, switch power off at service
panel and lock service disconnecting means to prevent power
from being switched on accidentally. When the service disconnecting means cannot be locked, securely fasten a prominent warning device, such as a tag, to the service panel.
3. Installation work and electrical wiring must be done by qualified personnel in accordance with all applicable codes and
standards, including fire-rated construction codes and standards.
4. Sufficient air is needed for proper combustion and exhausting of gases through the flue (chimney) of fuel burning equipment to prevent backdrafting.Follow the heating equipment
manufacturer’s guidelines and safety standards such as those
published by the National Fire Protection Association (NFPA),
and the American Society for Heating, Refrigeration and Air
Conditioning Engineers (ASHRAE), and the local code authorities.
5. When cutting or drilling into wall or ceiling, do not damage
electrical wiring and other hidden utilities.
6. Ducted fans must always be vented to the outdoors.
7. Do not use this range hood with any additional solid-state
speed control device.
8. To reduce the risk of fire, use only steel ductwork.
9. This unit must be grounded.
TO REDUCE THE RISK OF A RANGE TOP GREASE FIRE:
a) Never leave surface units unattended at high settings.
Boilovers cause smoking and greasy spillovers that may ignite. Heat oils slowly on low or medium settings.
b) Always turn hood ON when cooking at high heat or when cook-
ing flaming foods.
c) Clean ventilating fans frequently. Grease should not be al-
lowed to accumulate on fan or filter.
d) Use proper pan size. Always use cookware appropriate for
the size of the surface element.
WARNING
TO REDUCE THE RISK OF INJURY TO PERSON(S) IN THE
EVENT OF A RANGE T OP GREASE FIRE,OBSERVE THE FOLLOWING*:
1. SMOTHER FLAMES with a close-fitting lid, cookie sheet, or
metal tray, then turn off the burner. BE CAREFUL TO PREVENT BURNS. IF THE FLAMES DO NOT GO OUT IMMEDIATELY, EVACUATE AND CALL THE FIRE DEPARTMENT.
2. NEVER PICK UP A FLAMING PAN – You may be burned.
3. DO NOT USE WATER, including wet dishcloths or towels –
This could cause a violent steam explosion.
4. Use an extinguisher ONLY if:
A. You know you have a Class ABC extinguisher and you know
how to operate it.
B. The fire is small and contained in the area where it started.
C. The fire department has been called.
D. You can fight the fire with your back to an exit.
* Based on “Kitchen Fire Safety Tips” published by NFPA.
CAUTION
1. For general ventilating use only. Do not use to exhaust hazardous or explosive materials and vapors.
2. To avoid motor bearing damage and noisy and/or unbalanced
impellers, keep drywall spray, construction dust, etc. off power
unit.
3. This blower has a thermal overload which will automatically
shut off the motor if it becomes overheated.The motor will
restart when it cools down.If the motor continues to shut off
and restart, have the hood serviced.
4. For best capture of cooking impurities, the bottom of the hood
should be a minimum of 24” and a maximum of 30” above the
cooking surface.
5. Please read specification label on product for further information and requirements.
6. To reduce the risk of fire and to properly exhaust air on a
ducted installation, be sure to duct air outside – Do not exhaust air into spaces within walls or ceiling or into attics, crawl
spaces, or garage.
7. This product is equipped with a thermostat which may start
blower automatically. To reduce the risk of injury and to prevent power from being switched on accidentally, switch power
off at service panel and lock or tag service panel.
8. The P6 Blower must be installed with K260A Series Range
Hoods only. The P12 Blower must be installed with K260A or
K260D Series Range Hoods only. Other Range Hoods cannot be substituted. (Range Hood sold separately.)
INSTALLER:
Save this manual for Electrical
1
Inspector and Homeowner to use.
HL0081
Model 415
(7” round adjustable elbow)
Model 427
(4
1
/2” x 181/2”
to 10” Round,
6” high - lateral
Model 423
(41/2” x 181/2” to
10” Round - vertical
Model 424
(41/2” x 181/2” to
10” Round - horiz.
front/rear
Model 454
(41/2” x 181/2”
to 10” Round -
horiz. /right
Model 453
(41/2” x 181/2”
to 10” Round -
horiz. /left
WP29M
SERIES HOOD
(Canopy with
blower controls
& lighting.
Required for all
installations.)
OPTIONAL
DECORATIVE FLUE
AEWP SERIES
OPTIONAL
FLAT TOP COVER
ADPWP SERIES
NON-DUCT KIT FLUE
ANKWP SERIES
NOTE: We recommend the non-duct kit flue
ANKWP Series be installed with
Model P6 Blower/Rough-in kit.
Model 437
(High capacity roof cap)
Model 441
(10’’ Round wall cap)
Model 634 or 644
(roof cap)
Model 647
(7” Round wall cap)
Model 407
(7” round duct—2 ft. sections)
Model 410
(10” round duct—2 ft. sections)
MODEL P6
BLOWER/ROUGH-IN KIT
(600 cfm interior blower &
rough-in plate)
MODEL P12
BLOWER/ROUGH-IN KIT
(1200 cfm interior blower
& rough-in plate)
Model 418
(10” round adjustable elbow)
W all & Roof Caps,
Exterior Blowers
Elbows & In-Line
Dampers
Ductwork
Choose 1 of 5
Discharge T ransitions
Choose 1 of 2
Blower Systems
INTERNAL BLOWERS
RANGE HOOD SYSTEM
2
MODEL P6 SINGLE-WHEEL BLOWER
MODEL P12 DUAL-WHEEL BLOWER
VERTICAL DISCHARGE
ROUGH-IN PLATE
MOUNTING
STUDS
1. Mount rough-in plate to mounting studs on inside, top of hood. Use hex nuts
provided. Make sure power cord is at right side of hood.
2. Loosen barrel nuts and wing nut half-way.
3. Lift blower to rough-in plate and over barrel nuts. Slide blower sideward to
engage barrel nuts with small end of keyholes and wing nut with slot.
4. Tighten nuts to secure blower to rough-in plate.
5. Plug rough-in plate power cord and blower power cord into receptacles inside of hood. DO NOT PLUG POWER CORDS TOGETHER.
ROUGH-IN PLATE POWER CORD
(Locate at right side of hood)
MOUNTING
STUDS
BARREL
NUTS
WING
NUT
BLOWER
POWER CORD
HORIZONTAL DISCHARGE
COVER PLATE
ROUGH-IN PLATE POWER CORD
(Locate at right side of hood)
VERTICAL DISCHARGE
ROUGH-IN PLATE
ROUGH-IN PLATE
SLOT
MOUNTING
STUDS
BARREL NUT
1. Mount rough-in plate to mounting studs on inside, top of hood. Use hex nuts
provided. Make sure power cord is at right side of hood.
2. Loosen barrel nut half-way.
3. Lift blower to rough-in plate. Slide blower back to engage blower tab with
slot in rough-in plate and slot in blower with barrel nut.
4. Tighten barrel nut to secure blower to rough-in plate.
5. Plug rough-in plate power cord and blower power cord into receptacles inside of hood. DO NOT PLUG POWER CORDS TOGETHER.
POWER CORD
(Locate at
right side
of hood)
MOUNTING
STUDS
BLOWER
TAB
BLOWER
POWER
CORD
HORIZONTAL DISCHARGE
ROUGH-IN PLATE POWER CORD
COVER PLATE
(Locate at right side of hood)
MOUNTING
STUDS
ROUGH-IN
PLATE
MOUNTING
STUDS
BARREL
NUTS
1. Remove cover plate from inside, back of hood and mount it to inside, top of
hood with same hardware. Make sure power cord is at right side of hood.
2. Mount rough-in plate to mounting studs on inside, back of hood. Use hex
nuts provided.
3. Loosen barrel nuts and wing nut half-way.
4. Lift blower to rough-in plate and over barrel nuts. Slide blower sideward to
engage barrel nuts with small end of keyholes and wing nut with slot.
5. Tighten nuts to secure blower to rough-in plate.
6. Plug rough-in plate power cord and blower power cord into receptacles inside of hood. DO NOT PLUG POWER CORDS TOGETHER.
WING NUT
BLOWER
POWER CORD
SLOT
MOUNTING
STUDS
TAB
(at bottom-back
of blower)
1. Remove cover plate from inside, back of hood and mount it to inside, top of
hood with same hardware. Make sure power cord is at right side of hood.
2. Mount rough-in plate to mounting studs on inside, back of hood. Use hex
nuts provided.
3. Loosen barrel nut half-way.
4. Lift blower to rough-in plate. Slide blower down to engage blower tab with
slot in rough-in plate and slot in blower with barrel nut.
5. Tighten barrel nut to secure blower to rough-in plate.
6. Plug rough-in plate power cord and blower power cord into receptacles inside of hood. DO NOT PLUG POWER CORDS TOGETHER.
BARREL NUT
3
MOUNTING
STUDS
BLOWER
POWER
CORD
SERVICE PARTS
Model P6
Single-Wheel Blower / Rough-in Plate
KEYPART
NO.NUMBERDESCRIPTIONQTY.
197010792Damper Assembly1
299170245Screw, #8-18 x 3/8*4
397014276Rough-in Plate Weldment1
499100387Polyfoam
599380605Barrel Nut2
699150471Screw, #10-32 x ½ Hex Washer Head2
798003370Outlet Box Cover1
899100382Strain Relief1
999440033Power Cord1
1099260472Wing Nut1
‡97002302Parts Bag (Contains (6) #10-16 x 1½1
Slotted Pan Head Machine
Screws*)
97014155Rough-in Kit (complete)
* Standard Hardware. May be purchased locally.
‡ Not shown.
Broan warrants to the original consumer purchaser of its products that such products will be free from defects in materials or workmanship
for a period of one year from the date of original purchase. THERE ARE NO OTHER WARRANTIES, EXPRESS OR IMPLIED,
INCLUDING, BUT NOT LIMITED TO, IMPLIED WARRANTIES OR MERCHANT ABILITY OR FITNESS FOR A PARTICULAR
PURPOSE.
During this one-year period, Broan will, at its option, repair or replace, without charge, any product or part which is found to be defective
under normal use and service.
THIS WARRANTY DOES NOT EXTEND TO FLUORESCENT LAMP STARTERS, TUBES, HALOGEN AND INCANDESCENDT BULBS.
This warranty does not cover (a) normal maintenance and service or (b) any products or parts which have been subject to misuse,
negligence, accident, improper maintenance or repair (other than by Broan), faulty installation or installation contrary to recommended
installation instructions.
The duration of any implied warranty is limited to the one-year period as specified for the express warranty. Some states do not allow
limitation on how long an implied warranty lasts, so the above limitation may not apply to you.
BROAN’S OBLIGATION TO REPAIR OR REPLACE, AT BROAN’S OPTION, SHALL BE THE PURCHASER’S SOLE AND EXCLUSIVE
REMEDY UNDER THIS WARRANTY. BROAN SHALL NOT BE LIABLE FOR INCIDENTAL, CONSEQUENTIAL OR SPECIAL
DAMAGES ARISING OUT OF OR IN CONNECTION WITH PRODUCT USE OR PERFORMANCE.
Some states do not allow the exclusion or limitation of incidental or consequential damages, so the above limitation or exclusion may
not apply to you.
This warranty gives you specific legal rights, and you may also have other rights, which vary from state to state. This warranty supersedes
all prior warranties.
To qualify for warranty service, you must (a) notify Broan at the address or telephone number below, (b) give the model number and part
identification and (c) describe the nature of any defect in the product or part. At the time of requesting warranty service, you must present
evidence of the original purchase date.
Best by Broan, P. O. Box 140, Hartford, Wisconsin 53027 (1-800-637-1453)