MODEL P2RW - 2 ROCKER SWITCH
2-ROCKER
SWITCH
RED
BLACK
BLACK
GROUND
WHITE
WHITE
120 VAC
LINE IN
TO
HOOD
MODEL P3RW - 3 ROCKER SWITCH
Control 2 or 3 devices independently
SAFETY WARNINGS
ALL ELECTRICAL WORK MUST BE DONE IN
ACCORDANCE WITH LOCAL CODES, ORDINANCES,
OR NATIONAL ELECTRICAL CODE AS APPLICABLE.
FOR SAFETY, THIS PRODUCT MUST BE INSTALLED IN
A GROUNDED SWITCH BOX. IF YOU ARE UNFAMILIAR
WITH METHODS OF INSTALLING ELECTRICAL
WIRING, SECURE THE SERVICES OF A QUALIFIED
ELECTRICIAN.
Turn off power before installing or wiring this product
and test that the power is off.
Use this rocker switch only with copper wire. Do not
use aluminum wire with this device.
To prevent serious injury from electrical shock or
damage to electrical components – DO NOT WIRE HOT!
Turn off power breaker to this switch.
Total load for the multi-rocker switch is rated at 15
amps, @ 120 VAC.
Do not exceed maximum electrical ratings.
Warranty is void if miswired.
INSTALLATION STEPS
1. To avoid fire or electrical shock, turn OFF power at
circuit breaker or fuse. Test that the power is OFF
before working.
2. MOUNT THE SWITCH BOX
USING A ROCKER SWITCH TO ACTIVATE A RANGE
HOOD
FIG. I
* 2- SPEED
HOODS
CUT BLACK
JUMPER WIRE
HERE!
Install a 2 1/2 inch deep single-gang switch box or a
2 inch deep double-gang switch box.
3. CONNECT WIRING
General instructions for all configurations:
Make sure both the switch box and the appliance are
properly grounded.
Make sure ground wire is securely fastened to rocker
switch’s ground screw. Tighten ground screw 14 to
16-in. lbs. torque.
Figure #1
1 20 VAC
LINE IN
BLACK
BREAK-OFF
AB INTACT
GROUND
2 ROCKER SWITCH
SWITCH BOX APPLIANCE
RED
BLACK
WHITEWHITE
LOAD
1
LOAD
2
Remove insulation, approx. 5/8 inch. Use proper
wire nut sizes for number and size of wires.
For screw terminals: Use #12 or #14-AWG solid
copper wire only. Tighten screw terminals 14 to 16
inch lbs. torque.
For 3-rocker units: Strip wires to length of strip
gauge on the back of the switch. Connect wires per
the FIGURE #3 wiring diagram.
For 2 rocker units: Connect wires per either the
FIGURE #1 wiring diagram (two single pole switches
on the same circuit) or the FIGURE #2 wiring diagram
(two single pole switches on separate circuits). With
either method, each single pole switch controls an
independent function.
NOTE: For separate feed (FIGURE #2) operation
only: The break-off tab located between the black
screws should be removed before wiring. Using a
standard slotted screwdriver, move the screwdriver
up and down in the vertical direction until the tab
breaks off.
4. MOUNT ROCKER SWITCH IN SWITCH BOX
Tuck wires into switch box and fasten the rocker
switch to box using attached screws.
5. ATTACH SWITCH PLATE
Fasten a switch plate (not included) to the rocker
switch
Figure #2
1 20 VAC
LINE 1 IN
BREAK-OFF
TAB REMOVED
1 20 VAC
LINE 2 IN
GROUND
Figure #3
(with single device adapter plate) APPLIANCE
120 VA C
LINE IN
GROUND
WHITE
2 ROCKER SWITCH
SWITCH BOX APPLIANCE
RED
BLACK
WHITEWHITE
LOAD
1
LOAD
2
3 ROCKER SWITCH
RED
BLACK
WHITE
BLACK
WHITE
LOAD
1
LOAD
2
LOAD
3
For more information on compatibility with Broan
and NuTone fans, refer to the wall control selection
guide on Broan-NuTone.com, Broan.ca or NuTone.ca.
1. When using a 2-Rocker Switch to turn a range hood ON & OFF from another location with 120 VAC POWER
CABLE ENTERING SWITCH BOX:
Remove the range hood’s wiring cover. If the hood has a BLACK JUMPER WIRE, it must be cut and the end
stripped as shown. (FIG. I)
Use UL approved clamps to secure all cables to hood and box. Make wiring connections following appropriate
diagram. Use proper wire nut sizes for number and size of wires. Replace range hood wiring cover.
OPTION 1
POWER INTO SWITCH
* 2- SPEED
HOODS
BLUE
REF. FIG 1
BLACK
** INTERMEDIATE
HOODS
CUT BLACK
JUMPER
WIRE HERE!
WHITE
** INTERMEDIATE
HOODS
BLACK
WHITE
FROM SWITCH
REF. FIG 1
BLUE
FROM SWITCH
RED
BLACK
GRN
BOX
BLACK
RED
BLACK
GRN
BOX
1101840B
BOÎTE DE JONCTION DOUBLE
(avec plaque pour un seul interrupteur) INTERRUPTEUR
2. When using a 2-Rocker Switch to turn a range
hood ON & OFF from another location with 120 VAC
POWER CABLE ENTERING HOOD:
Remove the range hood’s wiring cover. If the hood
has a BLACK JUMPER WIRE, it must be cut and the
end stripped as shown. (FIG. I)
Use UL approved clamps to secure all cables to
hood and box. Make wiring connections following
appropriate diagram. Use proper wire nut sizes for
number and size of wires. Replace range hood wiring
cover.
For Warranty Statement, Service Parts, Technical
Support, or to Register your product, please visit our
website or call:
In the United States - Broan.com 800-637-1453 or
NuTone.com 888-336-6151. In Canada - Broan.ca or
NuTone.ca 877-896-1119
OPTION 2
POWER INTO HOOD
SWITCH
RED
‡
WHITE
BLACK
FROM
For more information on compatibility with Broan
and NuTone range hoods, refer to the range hood
compatibility list on Broan-NuTone.com, Broan.ca
or NuTone.ca.
* 2- SPEED
HOODS
BLUE
WHITE
WHITE
TO SWITCH
‡
BOX
REF. FIG 1
BLACK
BLACK
RED
GROUND
120 VAC
LINE IN
** INTERMEDIATE
HOODS
BLACK
WHITE
‡
WHITE
TO SWITCH
BOX
‡
CODE REQUIRES BOTH
REF. FIG 1
BLACK
BLUE
BLACK
RED
GROUND
120 VAC
LINE IN
ENDS OF THIS WIRE'S INSU-
LATION TO BE COLORED. USE
A PERMANENT MARKER.
MODÈLE P2RW - COMMANDE À DEUX FONCTIONS
MODÈLE P3RW - COMMANDE À TROIS FONCTIONS
Commande deux ou trois appareils séparément.
CONSIGNES DE SÉCURITÉ
TOUS LES TRAVAUX ÉLECTRIQUES DOIVENT ÊTRE
FAITS CONFORMÉMENT AUX CODES ET RÈGLEMENTS
LOCAUX APPLICABLES. POUR DES RAISONS DE
SÉCURITÉ, LE PRODUIT DOIT ÊTRE INSTALLÉ DANS
UNE BOÎTE DE JONCTION MISE À LA TERRE. EN CAS
DE DOUTE QUANT AU BRANCHEMENT DES FILS,
RECOURIR AUX SERVICES D’UN ÉLECTRICIEN.
Avant de commencer l’installation ou le branchement du
produit, couper le courant et vérifier que le circuit est hors
tension.
Utiliser la commande uniquement avec des fils en cuivre.
Ne pas utiliser avec des fils en aluminium.
Pour éviter les dommages aux composants électriques
et les blessures graves causées par l’électrocution, NE
PAS BRANCHER DES FILS SOUS TENSION. Couper
le courant en ouvrant le disjoncteur du circuit où sera
installé l’interrupteur.
La commande peut recevoir une charge totale nominale
de 15A à 120VCA.
Ne pas dépasser cette charge.
Garantie nulle en cas de mauvais branchement.
INSTALLATION
1.
Pour éviter les risques d’incendie et d’électrocution,
couper le courant en ouvrant le disjoncteur ou en
retirant le fusible. Vérifier que le circuit est hors
tension avant de commencer l’installation.
2. INSTALLER LA BOÎTE DE JONCTION
Installer une boîte de jonction simple de 2 ½ po de
profondeur ou une boîte de jonction double de 2po
de profondeur.
3. BRANCHER LES FILS
Instructions générales pour toute installation :
Veiller à ce que la boîte de jonction et l’interrupteur
soient correctement mis à la terre.
Vérifier que le fil de mise à la terre est bien fixé à la
vis de mise à la terre de l’interrupteur. Serrer la vis de
mise à la terre à un couple de 1,6 à 1,8N·m (14 à 16
po/lb).
Retirer environ 1,6 cm (5/8 po) de gaine des fils.
Utiliser des capuchons de connexion de la taille
appropriée au nombre de fils et à leur calibre.
Pour les connexions aux bornes à vis, utiliser
uniquement des fils rigides (monobrin) en cuivre de
calibre 12 ou 14AWG. Serrer les bornes à vis à un
couple de 1,6 à 1,8N·m (14 à 16 po/lb).
Pour la commande à trois fonctions, dégainer
l’extrémité des fils en utilisant le guide de longueur
au dos de l’interrupteur. Brancher les fils comme
l’indique le schéma de câblage à la figure3.
Pour la commande à deux fonctions, brancher
les fils comme l’indique le schéma de câblage à la
figure 1 (pour deux commandes unipolaires sur
un même circuit) ou celui à la figure2 (pour deux
commandes unipolaires sur deux circuits). Peu
importe la méthode, les deux commandes unipolaires
commandent chacun une fonction.
N.B. : Avant de brancher les fils dans une installation
à deux circuits (figure 2), retirer la languette
d’interruption entre les deux vis noires de la
commande avec un tournevis à pointe plate. Bouger
le tournevis de haut en bas jusqu’à ce que la languette
se détache.
4. FIXER
LA COMMANDE
À BASCULE DANS LA BOÎTE
DE JONCTION
Pousser les fils dans la boîte de jonction et y fixer la
commande avec les vis fournies.
5. INSTALLER LA PLAQUE MURALE
Fixer une plaque murale (non comprise) sur la
commande à bascule.
Figure 1
COMMANDE À DEUX FONCTIONS
A LIMENTATION
DE 120 V CA
N OIR
L ANGUETTE
INTACTE
MISE À
LA TERRE
Figure 2
A LIMENTATION 1
DE 120 V CA
L ANGUETTE
A LIMENTATION 2
DE 120 V CA
MISE À LA TERRE
Figure 3
ALIMENTATION
DE 120 V CA
MISE À
LA TERRE
BLANC
SIMPLEI
ROUGE
N OIR
BLANCBLANC
CHARGE
1
CHARGE
2
COMMANDE À DEUX FONCTIONS
SIMPLEI
ROUGE
RETIRÉE
N OIR
BLANCBLANC
CHARGE
CHARGE
COMMANDE À TROIS FONCTIONS
ROUGE
NOIR
BLANC
NOIR
BLANC
CHARGE
1
CHARGE
2
CHARGE
3
1
2
Pour plus de renseignements sur les ventilateurs Broan
et NuTone compatibles, consulter le guide de sélection
des ventilateurs sur Broan-NuTone.com, Broan.ca ou
NuTone.ca.
ACTIONNER UNE HOTTE DE CUISINIÈRE AU MOYEN
D’UNE COMMANDE À MULTIPLES FONCTIONS
FIG. I
* HOTTES À 2 VITESSES
COUPER LE FIL DE
RACCORDEMENT
NOIR ICI!
** HOTTES
INTERMÉDIAIRES
COUPER LE FIL