MODEL P2RW - 2 ROCKER SWITCH
SINGLE-GANG
T
SINGLE-GANG
DOUBLE-GANG SWITCH BOX
2-ROCKER
SWITCH
RED
BLACK
BLACK
GROUND
WHITE
WHITE
120 VAC
LINE IN
TO HOOD
MODEL P3RW - 3 ROCKER SWITCH
Control 2 or 3 devices independently
SAFETY WARNINGS
ALL ELECTRICAL WORK MUST BE DONE IN ACCORDANCE WITH LOCAL CODES, ORDINANCES, OR NATIONAL ELECTRICAL CODE AS APPLICABLE. FOR SAFETY, THIS PRODUCT MUST BE INSTALLED IN A GROUNDED SWITCH BOX. IF YOU ARE UNFAMILIAR WITH METHODS OF INSTALLING ELECTRICAL WIRING, SECURE THE SERVICES OF A QUALIFIED ELECTRICIAN.
Turn off power before installing or wiring this product and test that the power is off.
Use this rocker switch only with copper wire. Do not use aluminum wire with this device.
To prevent serious injury from electrical shock or damage to electrical components – DO NOT WIRE HOT! Turn off power breaker to this switch.
Total load for the multi-rocker switch is rated at 15 amps, @ 120 VAC.
Do not exceed maximum electrical ratings. Warranty is void if miswired.
INSTALLATION STEPS
1. To avoid fire or electrical shock, turn OFF power at circuit breaker or fuse. Test that the power is OFF before working.
2. MOUNT THE SWITCH BOX
USING A ROCKER SWITCH TO ACTIVATE A RANGE HOOD
FIG. I
* 2- SPEED
HOODS
CUT BLACK JUMPER WIRE HERE!
Install a 2 1/2 inch deep single-gang switch box or a
2 inch deep double-gang switch box.
3. CONNECT WIRING General instructions for all configurations: Make sure both the switch box and the appliance are
properly grounded.
Make sure ground wire is securely fastened to rocker
switch’s ground screw. Tighten ground screw 14 to 16-in. lbs. torque.
Figure #1
1 20 VAC
LINE IN
BLACK
BREAK-OFF
AB INTACT
GROUND
2 ROCKER SWITCH
SWITCH BOX APPLIANCE
RED
BLACK
WHITEWHITE
LOAD
1
LOAD
2
Remove insulation, approx. 5/8 inch. Use proper
wire nut sizes for number and size of wires.
For screw terminals: Use #12 or #14-AWG solid
copper wire only. Tighten screw terminals 14 to 16 inch lbs. torque.
For 3-rocker units: Strip wires to length of strip
gauge on the back of the switch. Connect wires per the FIGURE #3 wiring diagram.
For 2 rocker units: Connect wires per either the
FIGURE #1 wiring diagram (two single pole switches on the same circuit) or the FIGURE #2 wiring diagram (two single pole switches on separate circuits). With either method, each single pole switch controls an independent function.
NOTE: For separate feed (FIGURE #2) operation
only: The break-off tab located between the black screws should be removed before wiring. Using a standard slotted screwdriver, move the screwdriver up and down in the vertical direction until the tab breaks off.
4. MOUNT ROCKER SWITCH IN SWITCH BOX Tuck wires into switch box and fasten the rocker
switch to box using attached screws.
5. ATTACH SWITCH PLATE Fasten a switch plate (not included) to the rocker
switch
Figure #2
1 20 VAC
LINE 1 IN
BREAK-OFF
TAB REMOVED
1 20 VAC
LINE 2 IN
GROUND
Figure #3
(with single device adapter plate) APPLIANCE
120 VA C
LINE IN
GROUND
WHITE
2 ROCKER SWITCH
SWITCH BOX APPLIANCE
RED
BLACK
WHITEWHITE
LOAD
1
LOAD
2
3 ROCKER SWITCH
RED
BLACK
WHITE
BLACK
WHITE
LOAD
1
LOAD
2
LOAD
3
For more information on compatibility with Broan and NuTone fans, refer to the wall control selection guide on Broan-NuTone.com, Broan.ca or NuTone.ca.
1. When using a 2-Rocker Switch to turn a range hood ON & OFF from another location with 120 VAC POWER CABLE ENTERING SWITCH BOX:
Remove the range hood’s wiring cover. If the hood has a BLACK JUMPER WIRE, it must be cut and the end
stripped as shown. (FIG. I)
Use UL approved clamps to secure all cables to hood and box. Make wiring connections following appropriate
diagram. Use proper wire nut sizes for number and size of wires. Replace range hood wiring cover.
OPTION 1
POWER INTO SWITCH
* 2- SPEED
HOODS
BLUE
REF. FIG 1
BLACK
** INTERMEDIATE
HOODS
CUT BLACK JUMPER WIRE HERE!
WHITE
** INTERMEDIATE
HOODS
BLACK
WHITE
FROM SWITCH
REF. FIG 1
BLUE
FROM SWITCH
RED
BLACK
GRN
BOX
BLACK
RED
BLACK
GRN
BOX
1101840B
B OÎTE DE JONCTION
NTERRUPTEUR
B OÎTE DE JONCTION
NTERRUPTEUR
BOÎTE DE JONCTION DOUBLE
(avec plaque pour un seul interrupteur) INTERRUPTEUR
HOOD
2-ROCKER
GROUND
2. When using a 2-Rocker Switch to turn a range hood ON & OFF from another location with 120 VAC POWER CABLE ENTERING HOOD:
Remove the range hood’s wiring cover. If the hood
has a BLACK JUMPER WIRE, it must be cut and the end stripped as shown. (FIG. I)
Use UL approved clamps to secure all cables to
hood and box. Make wiring connections following appropriate diagram. Use proper wire nut sizes for number and size of wires. Replace range hood wiring cover.
For Warranty Statement, Service Parts, Technical Support, or to Register your product, please visit our website or call: In the United States - Broan.com 800-637-1453 or NuTone.com 888-336-6151. In Canada - Broan.ca or NuTone.ca 877-896-1119
OPTION 2
POWER INTO HOOD
SWITCH
RED
WHITE
BLACK
FROM
For more information on compatibility with Broan and NuTone range hoods, refer to the range hood compatibility list on Broan-NuTone.com, Broan.ca or NuTone.ca.
* 2- SPEED
HOODS
BLUE
WHITE
WHITE
TO SWITCH
BOX
REF. FIG 1
BLACK
BLACK
RED
GROUND
120 VAC
LINE IN
** INTERMEDIATE
HOODS
BLACK
WHITE
WHITE
TO SWITCH
BOX
CODE REQUIRES BOTH
REF. FIG 1
BLACK
BLUE
BLACK
RED
GROUND
120 VAC
LINE IN
ENDS OF THIS WIRE'S INSU-
LATION TO BE COLORED. USE
A PERMANENT MARKER.
MODÈLE P2RW - COMMANDE À DEUX FONCTIONS MODÈLE P3RW - COMMANDE À TROIS FONCTIONS
Commande deux ou trois appareils séparément.
CONSIGNES DE SÉCURITÉ
TOUS LES TRAVAUX ÉLECTRIQUES DOIVENT ÊTRE FAITS CONFORMÉMENT AUX CODES ET RÈGLEMENTS LOCAUX APPLICABLES. POUR DES RAISONS DE SÉCURITÉ, LE PRODUIT DOIT ÊTRE INSTALLÉ DANS UNE BOÎTE DE JONCTION MISE À LA TERRE. EN CAS DE DOUTE QUANT AU BRANCHEMENT DES FILS, RECOURIR AUX SERVICES D’UN ÉLECTRICIEN. Avant de commencer l’installation ou le branchement du produit, couper le courant et vérifier que le circuit est hors tension. Utiliser la commande uniquement avec des fils en cuivre. Ne pas utiliser avec des fils en aluminium. Pour éviter les dommages aux composants électriques et les blessures graves causées par l’électrocution, NE PAS BRANCHER DES FILS SOUS TENSION. Couper le courant en ouvrant le disjoncteur du circuit où sera installé l’interrupteur. La commande peut recevoir une charge totale nominale de 15A à 120VCA. Ne pas dépasser cette charge. Garantie nulle en cas de mauvais branchement.
INSTALLATION
1.
Pour éviter les risques d’incendie et d’électrocution, couper le courant en ouvrant le disjoncteur ou en retirant le fusible. Vérifier que le circuit est hors tension avant de commencer l’installation.
2. INSTALLER LA BOÎTE DE JONCTION
Installer une boîte de jonction simple de 2 ½ po de
profondeur ou une boîte de jonction double de 2po de profondeur.
3. BRANCHER LES FILS Instructions générales pour toute installation : Veiller à ce que la boîte de jonction et l’interrupteur
soient correctement mis à la terre.
Vérifier que le fil de mise à la terre est bien fixé à la
vis de mise à la terre de l’interrupteur. Serrer la vis de mise à la terre à un couple de 1,6 à 1,8N·m (14 à 16 po/lb).
Retirer environ 1,6 cm (5/8 po) de gaine des fils.
Utiliser des capuchons de connexion de la taille appropriée au nombre de fils et à leur calibre.
Pour les connexions aux bornes à vis, utiliser
uniquement des fils rigides (monobrin) en cuivre de calibre 12 ou 14AWG. Serrer les bornes à vis à un couple de 1,6 à 1,8N·m (14 à 16 po/lb).
Pour la commande à trois fonctions, dégainer
l’extrémité des fils en utilisant le guide de longueur au dos de l’interrupteur. Brancher les fils comme l’indique le schéma de câblage à la figure3.
Pour la commande à deux fonctions, brancher
les fils comme l’indique le schéma de câblage à la figure 1 (pour deux commandes unipolaires sur un même circuit) ou celui à la figure2 (pour deux commandes unipolaires sur deux circuits). Peu importe la méthode, les deux commandes unipolaires commandent chacun une fonction.
N.B. : Avant de brancher les fils dans une installation
à deux circuits (figure 2), retirer la languette d’interruption entre les deux vis noires de la commande avec un tournevis à pointe plate. Bouger le tournevis de haut en bas jusqu’à ce que la languette se détache.
4. FIXER
LA COMMANDE
À BASCULE DANS LA BOÎTE
DE JONCTION
Pousser les fils dans la boîte de jonction et y fixer la
commande avec les vis fournies.
5. INSTALLER LA PLAQUE MURALE Fixer une plaque murale (non comprise) sur la
commande à bascule.
Figure 1
COMMANDE À DEUX FONCTIONS
A LIMENTATION
DE 120 V CA
N OIR
L ANGUETTE
INTACTE
MISE À
LA TERRE
Figure 2
A LIMENTATION 1
DE 120 V CA
L ANGUETTE
A LIMENTATION 2
DE 120 V CA
MISE À LA TERRE
Figure 3
ALIMENTATION
DE 120 V CA
MISE À
LA TERRE
BLANC
SIMPLEI
ROUGE
N OIR
BLANCBLANC
CHARGE
1
CHARGE
2
COMMANDE À DEUX FONCTIONS
SIMPLEI
ROUGE
RETIRÉE
N OIR
BLANCBLANC
CHARGE
CHARGE
COMMANDE À TROIS FONCTIONS
ROUGE
NOIR
BLANC
NOIR
BLANC
CHARGE
1
CHARGE
2
CHARGE
3
1
2
Pour plus de renseignements sur les ventilateurs Broan et NuTone compatibles, consulter le guide de sélection des ventilateurs sur Broan-NuTone.com, Broan.ca ou NuTone.ca.
ACTIONNER UNE HOTTE DE CUISINIÈRE AU MOYEN D’UNE COMMANDE À MULTIPLES FONCTIONS
FIG. I
* HOTTES À 2 VITESSES
COUPER LE FIL DE RACCORDEMENT NOIR ICI!
** HOTTES
INTERMÉDIAIRES
COUPER LE FIL DE RACCORDE­MENT NOIR ICI!