Broan LOSONE SELECT L100 SERIES, LOSONE SELECT L150 SERIES, LOSONE SELECT L200 SERIES, LOSONE SELECT L250 SERIES, LOSONE SELECT L300 SERIES User Manual

LOSONE SELECT® L100 SERIES L150 SERIES
!
Cooking
Equipment
Floor
COOKING AREA
Do not install above or
inside this area.
45
o
45
o
NOT FOR USE IN
A COOKING AREA.
L200 SERIES L250 SERIES L300 SERIES
LOSONE SELECT
®
VENTILATORS
Ceiling/Wall Mount
READ AND SAVE THESE INSTRUCTIONS
WARNING
1. Use this unit only in the manner intended by the manufacturer. If you have questions, contact the manufacturer at the address or telephone number listed in the warranty.
2. Before servicing or cleaning unit, switch power off at service panel and lock the service disconnect­ing means to prevent power from being switched on accidentally. When the service disconnecting means cannot be locked, securely fasten a promi­nent warning device, such as a tag, to the service panel.
3. Installation work and electrical wiring must be done by a qualified person(s) in accordance with all ap­plicable codes and standards, including fire-rated construction codes and standards.
4. Sufficient air is needed for proper combustion and exhausting of gases through the flue (chimney) of fuel burning equipment to prevent backdrafting. Fol­low the heating equipment manufacturer’s guideline and safety standards such as those published by the National Fire Protection Association (NFPA), and the American Society for Heating, Refrigeration and Air Conditioning Engineers (ASHRAE), and the local code authorities.
5. When cutting or drilling into wall or ceiling, do not damage electrical wiring and other hidden utilities.
6. Ducted fans must always be vented to the outdoors.
7. To reduce the risk of fire, use only metal ductwork.
8. Models L100, L150, L200, L250, and L300 only:
If this unit is to be installed over a tub or shower, it
must be marked as appropriate for the application and be connected to a GFCI (Ground Fault Inter­rupter) - protected branch circuit.
9. Never place a switch where it can be reached from a tub or shower.
10. This unit must be grounded.
CAUTION
1. For general ventilating use only. Do not use to ex­haust hazardous or explosive materials and vapors.
2. To avoid motor bearing damage and noisy and/ or unbalanced impellers, keep drywall spray, con­struction dust, etc. off power unit.
3. Please read specification label on product for fur-
ther information and requirements.
Page 1
Warranty Period and Exclusions: Broan-NuTone LLC (the “Company”) warrants to the original consumer purchaser of its product (“you”) that the product (the “Product”) will be free from material defects in the Product or its workmanship for a period of one (1) year from the date of original purchase.
The limited warranty period for any replacement parts provided by the Company and for any Products repaired or replaced under this limited warranty shall be the remainder of the original warranty period.
This warranty does not cover speed controls, fluorescent lamp starters, tubes, halogen and incandescent bulbs, fuses, filters, ducts, roof caps, wall caps and other accessories for ducting that may be purchased separately and installed with the Product. This warranty also does not cover (a)normal maintenance and service, (b)normal wear and tear, (c)any Products or parts which have been subject to misuse, abuse, abnormal usage, negligence, accident, improper or insufficient maintenance, storage or repair (other than repair by the Company), (d)damage caused by faulty installation, or installation or use contrary to recommendations or instructions, (e)any Product that has been moved from its original point of installation, (f)damage caused by environmental or natural elements, (g)damage in transit, (h)natural wear of finish, (i)Products in commercial or nonresidential use, or (j)damage caused by fire, flood or other act of God. This warranty covers only Products sold to original consumers in the United States by the Company or U.S. distributors authorized by the Company.
This warranty supersedes all prior warranties and is not transferable from the original consumer purchaser. No Other Warranties: This Limited Warranty contains the Company’s sole obligation and your sole remedy for defective products. The
foregoing warranties are exclusive and in lieu of any other warranties, express or implied. THE COMPANY DISCLAIMS AND EXCLUDES ALL OTHER EXPRESS WARRANTIES, AND DISCLAIMS AND EXCLUDES ALL WARRANTIES IMPLIED BY LAW, INCLUDING WITHOUT LIMITATION THOSE OF MERCHANTABILITY AND FITNESS FOR A PARTICULAR PURPOSE. To the extent that applicable law prohibits the exclusion of implied warranties, the duration of any applicable implied warranty is limited to the period specified for the express warranty above. Some states do not allow limitations on how long an implied warranty lasts, so the above limitation may not apply to you. Any oral or written description of the Product is for the sole purpose of identifying it and shall not be construed as an express warranty.
Whenever possible, each provision of this Limited Warranty shall be interpreted in such manner as to be effective and valid under applicable law, but if any provision is held to be prohibited or invalid, such provision shall be ineffective only to the extent of such prohibition or invalidity, without invalidating the remainder of such provision or the other remaining provisions of the Limited Warranty.
Remedy: During the applicable limited warranty period, the Company will, at its option, provide replacement parts for, or repair or replace, without charge, any Product or part thereof, to the extent the Company finds it to be covered by and in breach of this limited warranty under normal use and service. The Company will ship the repaired or replaced Product or replacement parts to you at no charge. You are responsible for all costs for removal, reinstallation and shipping, insurance or other freight charges incurred in the shipment of the Product or part to the Company. If you must send the Product or part to the Company, as instructed by the Company, you must properly pack the Product or part—the Company is not responsible for damage in transit. The Company reserves the right to utilize reconditioned, refurbished, repaired or remanufactured Products or parts in the warranty repair or replacement process. Such Products and parts will be comparable in function and performance to an original Product or part and warranted for the remainder of the original warranty period.
Exclusion of Damages: THE COMPANY’S OBLIGATION TO PROVIDE REPLACEMENT PARTS, OR REPAIR OR REPLACE, AT THE COM­PANY’S OPTION, SHALL BE YOUR SOLE AND EXCLUSIVE REMEDY UNDER THIS LIMITED WARRANTY AND THE COMPANY’S SOLE AND EXCLUSIVE OBLIGATION. THE COMPANY SHALL NOT BE LIABLE FOR INCIDENTAL, INDIRECT, CONSEQUENTIAL OR SPECIAL DAMAGES ARISING OUT OF OR IN CONNECTION WITH THE PRODUCT, ITS USE OR PERFORMANCE.
Some states do not allow the exclusion or limitation of incidental or consequential damages, so the above limitation or exclusion may not apply to you. This warranty gives you specific legal rights, and you may also have other rights, which vary from state to state.
This warranty covers only replacement or repair of defective Products or parts thereof at the Company’s main facility and does not include the cost of field service travel and living expenses.
Any assistance the Company provides to or procures for you outside the terms, limitations or exclusions of this limited warranty will not constitute a waiver of such terms, limitations or exclusions, nor will such assistance extend or revive the warranty.
The Company will not reimburse you for any expenses incurred by you in repairing or replacing any defective Product, except for those incurred with the Company’s prior written permission.
How to Obtain Warranty Service: To qualify for warranty service, you must (a)notify the Company at the address or telephone number stated below within seven (7)days of discovering the covered defect, (b)give the model number and part identification and (c)describe the nature of any defect in the Product or part. At the time of requesting warranty service, you must present evidence of the original purchase date. If you cannot provide a copy of the original written limited warranty, then the terms of the Company’s most current written limited warranty for your particular product will control.The most current limited written warranties for the Company’s products can be found at www.broan.com .
Broan-NuTone LLC 926 West State Street, Hartford, WI 53027 www.broan.com 800-637-1453
Limited Warranty
Installer: Leave this manual with the homeowner.
Homeowner: Use and Care information on page 3.
LOSONE SELECT® L100 SERIES L150 SERIES
L200 SERIES L250 SERIES L300 SERIES
Page 2
TYPICAL INSTALLATION
MOUNTING (New Frame Construction)
ROUND DUCT*
ADDITIONAL
1½” FRAMING
Blower factory-shipped
in horizontal
discharge position.
GRILLE
(Polymeric
shown)
Install after
ceiling is
finished.
Mounting brackets
factory-shipped in
position for ½” ceil-
ing material.
CEILING JOIST
(16” centers shown)
MOUNTING
SCREW
GRILLE
SCREW
TYPICAL INSTALLATION
WIRING
BLACK
TO
BLACK
GROUND TO
WIRING PLATE
WHITE
TO
WHITE
Ventilator can be wired from outside of housing.
Use UL approved connectors to wire per local codes.
DUCTING (Horizontal blower discharge)
TOP / BACK
OF HOUSING
WIRING
LINE IN
PLATE
Factory-shipped unit installed in new construction.
MOUNTING (Existing Frame Construction)
2 X 4 FRAMING
(wide side down)
ROUND DUCT*
CEILING JOIST
(16” centers
shown)
MOUNTING BRACKETS
(Attached to
opposite sides
of housing & up-
side-down,
so housing is
flush with
finished ceiling)
GRILLE
(Polymeric shown)
Factory-shipped unit installed in existing construction.
* L100 & L150 Series uses 6” Round Duct. L200, L250, & L300 Series uses 8” Round Duct.
FINISHED
CEILING
MATERIAL
GRILLE
SCREW
ROOF CAP
ROUND
DUCT*
WALL
ROUND
ELBOW*
CAP
Two ways to connect ductwork to a factory-shipped unit.
* L100 & L150 Series uses 6” Round Duct. L200, L250, & L300 Series uses 8” Round Duct.
IMPORTANT:
Remove shipping tape from damper
Remove the shipping tape from the damper flap and make sure that damper flap opens and closes freely inside the ductwork. Use duct tape to make ductwork connections secure and air-tight.
Remove shipping ring from blower inlet
Remove the shipping ring from the blower inlet before operating the ventilator.
LOSONE SELECT® L100 SERIES L150 SERIES
12¼"
9
1
/
2
"
to
10
1
/
2
"
12¼"
1½"
to
2½"
12¼"
1
1
/
8
"
MAX.
12¼"
10
3
/
4"
to
11
3
/
4"
12¼"
12¼"
1
1
/
2
"
to
2
1
/
2
"
L200 SERIES L250 SERIES L300 SERIES
Page 3
MOUNTING OPTIONS
¼-20 hex nuts secure mounting brackets to housing. Loosen and re-tighten or remove and replace nuts as necessary for desired mounting bracket position.
Mounting brackets in
factory-shipped position.
(Outlet parallel to joists.)
(New construction)
Mounting brackets mounted
to outlet sides of housing.
(Outlet perpendicular to joists.)
(New construction)
Mounting brackets ipped
over and mounted to outlet
sides of housing.
(Outlet parallel to joists.)
(Existing construction)
Mounting brackets ipped
over to give approx. 1”
more clearance.
(Outlet parallel to joists.)
(New construction)
DUCTING OPTIONS
BLOWER DISCHARGE POSITIONS
DUCT
CONNECTOR
DUCT
CONNECTOR
BLOWER
Blower and duct connec-
tor in horizontal discharge
position. (Factory shipped)
DUCTING (Vertical blower discharge)
ROUND
DUCT*
Change
blower &
duct connec-
tor positions
for vertical discharge.
BLOWER
Blower and duct connec-
tor in vertical discharge
position.
ROOF CAP
Mounting brackets mounted
to top of sides of housing.
(Outlet parallel to joists.)
(New or existing construction)
Mounting brackets ipped
over and mounted to top of
sides of housing.
(Outlet parallel to joists.)
(New or existing construction)
WIRING OPTIONS
WIRING PLATE POSITION
HORIZONTAL POWER CABLE CONNECTION
Wiring plate mounts to side or top of housing.
VERTICAL
POWER CABLE
CONNECTION
* L100 & L150 Series uses 6” Round Duct. L200, L250, & L300 Series uses 8” Round Duct.
Typical ductwork connection to a ventilator converted to
vertical discharge.
USE AND CARE
Ventilator is designed for continuous operation. If desired, it may be controlled using an on/off switch or a solid-state, variable speed control. Follow wiring instructions packed with control, and adhere to all local and state codes, and the National Electrical Code.
WARNING: To reduce the risk of electric shock, disconnect from power supply before servicing.
To clean grille: Use appropriate vacuum attachment or remove
grille and clean with a soft cloth and mild soap or detergent. Dry grille thoroughly before reinstalling.
To clean blower assembly: Remove grille, unplug blower from housing, remove blower mounting nuts, and carefully remove blower from housing. Use appropriate vacuum attachment or a soft cloth and mild soap or detergent to clean blower discharge area and wheel. DO NOT ALLOW WATER TO ENTER MOTOR. Make sure blower assembly is completely dry before reinstalling.
Motor is permanently lubricated. Do not oil or disassemble motor.
LOSONE SELECT® L100 SERIES L150 SERIES
L200 SERIES L250 SERIES L300 SERIES
SERVICE PARTS SERVICE PARTS
Page 4
KEY NO. PART NO. DESCRIPTION
1 97014725 Housing Assembly (L100’s & L150’s) 97014726 Housing Assembly (L200’s thru L300’s) 2 97014728 Mounting Bracket (2 req.) 3 97014760 Damper Assembly (6” dia.) 97014761 Damper Assembly (8” dia.) 4 99150415 Screw, 8-18 x ¼ (12 req.)* 5 98005513 Wire Box Cover 6 99400035 Strain Relief Bushing 7 98005512 Wiring Plate 8 99150471 Ground Screw, 10-32 x ½ (2 req.) 9 97014774 Scroll Assembly (L100’s & L150’s) 97014775 Scroll Assembly (L200’s thru L300’s) 10 98009399 Inlet Ring 11 99110805 Blower Wheel 12 99080481 Motor (L100 & L100MG) 99080482 Motor (L150 & L150MG) 99080483 Motor (L200 & L200MG) 99080484 Motor (L250 & L250MG) 99080485 Motor (L300 & L300MG) 99080493 Motor (L100C) 99080494 Motor (L150C) 99080495 Motor (L200C) 99080496 Motor (L250C) 99080497 Motor (L300C) 99080503 Motor (L100EX) 99080504 Motor (L150EX) 99080505 Motor (L200EX) 99080506 Motor (L250EX) 99080507 Motor (L300EX) 13 99260558 Lock Nut, 8-32 (4 req.)* 14 99250959 Washer (4 req.)* 15 99100491 Grommet (4 req.) 9-15 Blower Assembly, Complete (Includes Key Nos. 9-15) 97014800 (L100 & L100MG) 97014801 (L150 & L150MG) 97014802 (L200 & L200MG) 97014803 (L250 & L250MG) 97014804 (L300 & L300MG) 97014878 (L100C) 97014879 (L150C) 97014880 (L200C) 97014881 (L250C) 97014882 (L300C) 97014888 (L100EX) 97014889 (L150EX) 97014890 (L200EX) 97014891 (L250EX) 97014892 (L300EX) 16 99260477 Nut, ¼-20 (6 req.)* 17 97006039 Wire Harness 18 99500390 Wrapper Insulation 19 99500391 Side Insulation (2 req.) 20 99420466 Insulation Mounting Clip 21 99110807 Polymeric Grille 22 98009416 Metal Grille (“MG” suffix Models) 23 99420470 Grille Nut (2 req.) 24 99150472 Grille Mounting Screw (2 req.) 25 99150591 Screw, 10-16 x 7/8 (4 req.)*
4
3
7
1
4
20
8
2
25
23
20
16
25
4
6
5
19
17
19
4
18
10
15
11
12
BLOWER AS-
SEMBLY
13
9
14
16
21
24
Order replacement parts by PART NO. - not by KEY NO. * Standard hardware - may be purchased locally.
22
99042810D
Loading...
+ 8 hidden pages