Broan LOSONE SELECT L2000L, LOSONE SELECT L3500EXL Instructions Manual

LOSONE SELECT® IN-LINE
!
Cooking
Equipment
Floor
COOKING AREA
Do not install above or
inside this area.
45
o
45
o
NOT FOR USE IN
A COOKING AREA.
CABINET VENTILATORS
READ AND SAVE THESE INSTRUCTIONS
MODELS L2000L • L3500EXL
Page 1
WARNING
TO REDUCE THE RISK OF FIRE, ELECTRIC SHOCK, OR INJURY TO PERSONS, OBSERVE THE FOLLOWING:
1. Use this unit only in the manner intended by the manufacturer. If you have questions, contact the manufacturer at the address or telephone number listed in the warranty.
3. Installation work and electrical wiring must be done by a qualified person(s) in accordance with all applicable codes and standards, including fire-rated construction codes and standards.
4. Sufficient air is needed for proper combustion and exhausting of gases through the flue (chimney) of fuel burning equipment to prevent backdrafting. Follow the heating equipment manufacturer’s guideline and safety standards such as those published by the National Fire Protection Association (NFPA), and the American Society for Heating, Refrigeration and Air Conditioning Engineers (ASHRAE), and the local code authorities.
5. When cutting or drilling into wall or ceiling, do not damage electrical wiring and other hidden utilities.
6. Ducted fans must always be vented to the outdoors.
7. This unit must be grounded.
CAUTION
1. For general ventilating use only. Do not use to exhaust hazardous or explosive materials and vapors.
2. To avoid motor bearing damage and noisy and/or unbalanced impel­lers, keep drywall spray, construction dust, etc. off power unit.
3. Please read specification label on product for further information and requirements.
PLAN INSTALLATION
MOUNTING (Right-angle Discharge)
MOUNTING
3/8” MIN.
THREADED ROD
(By Others)
ACCESS
PANEL
DUCT
FLANGES
INTAKE
Factory shipped ready to be installed as a ceiling
ventilator with right-angle discharge.
MOUNTING (In-line Configuration)
3/8” MIN.
THREADED ROD
(By Others)
INTAKE
CHANNELS
EXHAUST
CEILING
GRILLE KIT
ADJUSTABLE
BRACKET
INTAKE
EXHAUST
DUCT
FLANGES
ACCESS
PANEL
Converted for in-line applications.
Installer: Leave this manual with
the homeowner.
Homeowner: Use and Care
information on page 3.
MODELS L2000L • L3500EXL
PLAN INSTALLATION (cont.) MOUNTING OPTIONS
CONVERTING FROM RIGHT-ANGLE TO IN-LINE
ACCESS
PANEL
EXHAUST
DUCT FLANGE
EXHAUST
DUCT FLANGE
INTAKE DUCT
FLANGES
Remove and reverse duct anges and access panel
positions on housing.
For correct intake and exhaust duct size, see Table 1.
DIM. L2000L L3500EXL C 12-5/8” 12-5/8”
D 39-5/8” 47-3/8”
THREADED RODS
Page 2
3/8” MIN.
(By Others)
TABLE 1
MODEL INTAKE DUCT SIZE EXHAUST DUCT SIZE L2000L 12-3/8” x 35-3/4” 7-3/4” x 33-3/4” L3500EXL 14-1/2” x 43-1/2” 9-3/4” x 41-3/8”
MOUNTING OPTIONS
Provide solid support to minimize sound leves. There are two basic mounting methods for these units.
3/8” MIN. THREADED RODS
(By Others)
DIM. L2000L L3500EXL A 7-3/4” 10-1/4”
B 33-3/4” 41-3/4”
Mounting with threaded rod through adjustable
mounting brackets located at top of housing.
Mounting brackets can be bolted to housing ends in a variety of configurations. Use screws and nuts provided in parts bag.
Typical mounting with threaded rod through
mounting channels on top of housing.
Mounting with threaded rods through adjustable
mounting brackets located at bottom of housing.
If installing unit as a ceiling ventilator, make sure that either duct flanges or housing will be flush with finished ceiling. Duct flanges may be removed and discarded if they interfere with a ceiling installation.
MODELS L2000L • L3500EXL
Page 3
MOUNTING OPTIONS
EXHAUST
SLEEPER
1-1/4”
INTAKE
ACCESS
PANEL
Typical wall mounting with 3/8” threaded fasteners
(by others) through mounting brackets.
ELECTRICAL CONNECTIONS
Connect electrical power cable to housing with proper connector for type of cable used. Provide 6” leads inside wiring box.
ACCESSORY INSTALLATIONS
If ventilator will discharge directly outside, install adamper kit to prevent backdrafts. A grille kit is available for applications where ventilator is installed with direct or remote room air intake.
CEILING
GRILLE
SCREWS
CABINET FLUSH
GRILLE
NUTS
Snap screw bushings into square openings around intake
opening. Install grille with screws provided.
NOTE: If duct flanges around intake opening interfere with instal­lation, remove them. Make sure that housing is flush with finished ceiling when ventilator is mounted.
DUCT FLANGES
INSIDE DAMPER
BUSHING
(Inside of frame)
MOTORMOTOR
MODEL
L2000L
SPEED CONTROL
LINE IN
120 VAC
60 HZ
MODEL
L3500EXL
LINE IN
240 VAC
60 HZ
1 PHASE
OR SWITCH
SPEED CONTROL
OR SWITCH
WHITE
GND
BLK
RED GND
BLK
MOTOR
ACCESSORIES
DAMPER GRILLE SPEED VIBRATION MODEL KIT KIT CONTROL HANGER
L2000L D100 G102 72V / 72W V104 L3500EXL D101 G103 75V V104
OUTSIDE
DAMPER BUSHING
(Snaps over rod)
(Inserts into inside bushing)
ROD
DAMPER FLAP
(Should open freely)
Install damper ap using rod provided.
USE AND CARE
Ventilator is designed for continuous operation. If desired, it may be controlled using an on/off switch or a solid-state, variable speed control. Follow wiring instructions packed with control, and adhere to all local and state codes, and the National Electrical Code.
WARNING: To reduce the risk of electric shock, disconnect from power supply before servicing.
To clean grille: Use appropriate vacuum attachment or remove
grille and clean with a soft cloth and mild soap or detergent. Dry grille thoroughly before reinstalling.
To clean blower assembly: Remove either access panel or ceiling grille. Unplug blower assembly. Provide safe support for blower as­sembly. Remove blower mounting screws and lift blower assembly out of housing. Gently vacuum housing and blower motor. Vacuum or gently wash blower wheels and housings. DO NOT ALLOW WATER TO ENTER MOTOR. Make sure blower assembly is completely dry before reinstalling. Replace blower assembly in housing and plug assembly in. Replace grille and/or access panel.
Motor is permanently lubricated. Do not oil or disassemble motor.
MODELS L2000L • L3500EXL
SERVICE PARTS SERVICE PARTS
KEY MODEL L2000L MODEL L3500EXL NO. PART NO. QTY. PART NO. QTY. DESCRIPTION
1 99420466 27 99420466 27 Insulation Clip 2 99170261 16 99170261 18 #5/16 - 18 x ½ Ser-
3 98006462 2 98006462 2 Mounting Bracket 4 97008107 1 97008108 1 Cabinet Body 5 93260447 12 93260447 14 #5/16 - 18 Lock
6 99150471 2 ---- -- #10-32 x ½ Green
7 99150490 42 99150490 44 #10B x 3/8 Ser-
8 99270658 1 99270658 1 Outlet Box Cover 9 99160319 2 99160319 2 #6-32 x 3/8 Ma-
10 99270656 1 99270657 1 Receptacle 11 99270659 1 99270659 1 Outlet Box 12 98006364 2 98006376 2 Duct Inlet Flange -
13 98006363 2 98006375 2 Duct Inlet Flange -
14 99500335 2 99500339 2 Bottom Panel
15 99500333 1 99500337 1 Back Panel Insula-
16 99500334 2 99500338 2 End Panel Insula-
17 98006699 1 98006700 1 Access Panel 18 99500336 1 99500340 1 Access Panel
19 97007450 1 97007451 1 Blower Platform 20 98006475 4 98006476 4 Venturi Ring 21 97007453 1 97007455 1 Right Hand Scroll 22 99020172 1 99020174 1 Blower Wheel -
23 99260477 10 99260477 12 ¼-20 Lock Nut 24 98006365 1 98006377 1 Blower Support
25 99080194 1 99080195 1 Motor 26 98006381 1 98006382 1 Motor Platform 27 99020173 1 99020175 1 Blower Wheel -
28 97007452 1 97007454 1 Left Hand Scroll 29 G-102 1 G-103 Grille Kit (contains
30 99420470 8 99420470 8 Grille Nut 31 98006477 1 98006478 1 Grille 32 99150472 8 99150472 8 #8-18 x 1¼ Grille
33 D-100 1 D-101 1 Damper Kit (con-
34 99100379 4 99100379 4 Damper Bushing 35 98006479 2 98006480 2 Damper Flap 36 98006481 2 98006472 2 Damper Rod 37 99760002 2 99760002 2 Damper Flap Mag-
** 97007448 1 97007448 1 Parts Bag (con-
Order replacement parts by PART NO. - not by KEY NO. ** Not Shown
rated Hex Head Screw
Nut
Ground Screw
rated Pan Head Screw
chine Screw
short
long
Insulation
tion
tion
Insulation
clockwise
Channel
counter-clockwise
Key Nos. 30, 31 &
32)
Screw
tains Key Nos. 34, 35, 36 & 37)
net
tains 4 ea. of Key Nos. 2 & 5)
WARRANTY
Broan warrants to the original consumer purchaser of its products that such products will be free from defects in materials or workmanship for a period of one year from the date of original purchase. THERE ARE NO OTHER WARRANTIES, EXPRESS OR IMPLIED, INCLUDING, BUT NOT LIMITED TO, IMPLIED WARRANTIES OF MERCHANTABILITY OR FITNESS FOR A PARTICULAR PURPOSE.
During this one-year period, Broan will, at its option, repair or replace, without charge, any product or part which is found to be defective under normal use and service.
THIS WARRANTY DOES NOT EXTEND TO FLUORESCENT LAMP STARTERS AND TUBES. This warranty does not cover (a) normal maintenance and service or (b) any products or parts which have been subject to misuse, negligence, accident, improper maintenance or repair (other than by Broan), faulty installation or installation contrary to recommended installation instructions.
The duration of an implied warranty is limited to the one-year period as specified for the express warranty. Some states do not allow limitation on how long an implied warranty lasts, so the above limitation may not apply to you.
BROAN’S OBLIGATION TO REPAIR OR REPLACE, AT BROAN’S OPTION, SHALL BE THE PURCHASER’S SOLE AND EXCLUSIVE REMEDY UNDER THIS WARRANTY. BROAN SHALL NOT BE LIABLE FOR INCIDENTAL, CONSEQUENTIAL OR SPECIAL DAMAGES ARISING OUT OF OR IN CONNECTION WITH PRODUCT USE OR PERFORMANCE. Some states do not allow the exclusion or limitation of incidental or consequential damages, so the above limitation may not apply to you.
This warranty gives you specific legal rights, and you may also have other rights, which vary from state to state. This warranty supersedes all prior warranties.
To qualify for warranty service, you must (a) notify Broan at the address stated below or telephone: 1-800-637-1453, (b) give the model number and part identification and (c) descr ibe the nature of any defect in the product or part. At the time of requesting warranty service, you must present evidence of the original purchase date.
In the U.S., contact: Broan-NuTone LLC, 926 West State Street, Hartford, WI 53027 (1­800-637-1453)
In Canada, contact: Broan-NuTone Canada, 1140 Tristar Drive Mississauga, Ontario L5T 1H9 (1-888-882-7626)
BROAN ONE YEAR LIMITED WARRANTY
Page 4
99042784D
Loading...