Broan L100L, L200L, L150L, L250L, L300L User Manual

MODELS
L100L • L150L • L200L • L250L • L300L
LOSONE SELECT
®
VENTILATORS
In-Line • 120V
READ AND SAVE THESE INSTRUCTIONS
WARNING
TO REDUCE THE RISK OF FIRE, ELECTRIC SHOCK, OR INJURY TO PERSONS, OBSERVE THE FOLLOWING:
1. Use this unit only in the manner intended by the manufacturer. If you have questions, contact the manufacturer at the address or telephone number listed in the warranty.
2. Before servicing or cleaning unit, switch power off at service panel and lock the service disconnecting means to prevent power from being switched on accidentally. When the service disconnecting means cannot be locked, securely fasten a prominent warning device, such as a tag, to the service panel.
3. Installation work and electrical wiring must be done by a qualified person(s) in accordance with all applicable codes and standards, including fire-rated construction codes and standards.
4. Sufficient air is needed for proper combustion and exhausting of gases through the flue (chimney) of fuel burning equipment to prevent backdrafting. Follow the heating equipment manufacturer’s guideline and safety standards such as those published by the National Fire Protection Association (NFPA), and the American Society for Heating, Refrigeration and Air Con­ditioning Engineers (ASHRAE), and the local code authorities.
5. When cutting or drilling into wall or ceiling, do not damage elec­trical wiring and other hidden utilities.
6. Ducted fans must always be vented to the outdoors.
7. To reduce the risk of fire, use only metal ductwork.
8. If this unit is to be installed over a tub or shower, it must be marked as appropriate for the application and be connected to a GFCI (Ground Fault Interrupter) - protected branch circuit.
9. Never place a switch where it can be reached from a tub or shower.
10. This unit must be grounded.
TO REDUCE THE RISK OF A RANGE TOP GREASE FIRE:
1. Never leave surface units unattended at high settings. Boilovers cause smoking and greasy spillovers that may ignite. Heat oils slowly on low or medium settings.
2. Always turn hood ON when cooking at high heat or when cooking flaming foods.
3. Clean ventilating fans frequently. Grease should not be allowed to accumulate on fan or filter.
4. Use proper pan size. Always use cookware appropriate for the size of the surface element.
TO REDUCE THE RISK OF INJURY TO PERSONS IN THE EVENT OF A RANGE TOP GREASE FIRE, OBSERVE THE FOLLOWING:*
1. SMOTHER FLAMES with a close-fitting lid, cookie sheet, or metal tray, then turn off the burner. BE CAREFUL TO PREVENT BURNS. If the flames do not go out immediately, EVACUATE AND CALL THE FIRE DEPARTMENT.
2. NEVER PICK UP A FLAMING PAN — You may be burned.
3. DO NOT USE WATER, including wet dishcloths or towels - violent steam explosion will result.
4. Use an extinguisher ONLY if: A. You know you have a Class ABC extinguisher and you al-
ready know how to operate it. B. The fire is small and contained in the area where it started. C. The fire department is being called. D. You can fight the fire with your back to an exit. * Based on “Kitchen Fire Safety Tips” published by NFPA.
Page 1
CAUTION
1. For general ventilating use only. Do not use to exhaust hazard­ous or explosive materials and vapors.
2. To avoid motor bearing damage and noisy and/or unbalanced impellers, keep drywall spray, construction dust, etc. off power unit.
3. If ventilator is installed in an unconditioned space (such as an attic): Surround the ventilator with thermal insulation - to minimize possible condensation.
4. Please read specification label on product for further informa­tion and requirements.
TABLE OF CONTENTS
This manual is divided into sections as follows:
• “TYPICAL INSTALLATION”
This section shows a common installation in new and existing, frame construction.
- Mounting (new construction)
- Mounting (existing construction)
- Wiring
- Ducting (straight through blower discharge)
• “MOUNTING OPTIONS”
• “WIRING OPTIONS”
- Wiring Plate Position
• “DUCTING OPTIONS”
- Blower Discharge Positions
- Ducting (right angle blower discharge)
• “USE AND CARE”
• “SERVICE PARTS”
• “WARRANTY”
Installer: Leave this manual with the homeowner.
Homeowner: Use and Care information on page 3.
MODELS
L100L • L150L • L200L • L250L • L300L
Page 2
TYPICAL INSTALLATION
MOUNTING
ADDITIONAL
1½” FRAMING
Blower factory-shipped
in straight through
discharge position.
(New Frame Construction)
ROUND DUCT*
Mounting brackets
factory-shipped in
position for ½”
ceiling material.
CEILING JOIST
(16” centers shown)
MOUNTING
SCREW
TYPICAL INSTALLATION
WIRING
BLACK
TO
BLACK
GROUND TO
WIRING PLATE
WHITE
TO
WHITE
120 VAC LINE IN
Ventilator can be wired from outside of housing.
Use UL approved connectors to wire per local codes.
TOP / BACK
OF HOUSING
WIRING
PLATE
Factory-shipped unit installed in new construction.
MOUNTING
CEILING JOIST
(16” centers
shown)
MOUNTING BRACKETS (Attached to
opposite sides
of housing &
upside-down)
(Existing Frame Construction)
2 X 4 FRAMING
(wide side down)
ROUND DUCT*
FINISHED
CEILING
MATERIAL
Factory-shipped unit installed in existing construction.
* L100L & L150L use 6” round duct.
L200L, L250L, & L300L use 8” round duct.
DUCTING
ROUND DUCT*
(Horizontal blower discharge)
ROOF CAP
ROUND
ELBOW*
WALL
CAP
Two ways to connect ductwork to a factory-shipped unit.
* L100L & L150L use 6” round duct.
L200L, L250L, & L300L use 8” round duct.
IMPORTANT:
Remove shipping tape from damper
Remove the shipping tape from the damper flap and make sure that damper flap opens and closes freely inside the ductwork. Use duct tape to make ductwork connections secure and air-tight.
Remove shipping ring from blower inlet
Remove the shipping ring from the blower inlet before operating the ventilator.
MODELS
"
"
L100L • L150L • L200L • L250L • L300L
Page 3
MOUNTING OPTIONS
¼-20 hex nuts secure mounting brackets to housing. Loosen and re-tighten or remove and replace nuts as necessary for desired mounting bracket position.
1
MAX.
12¼"
Mounting brackets in
factory-shipped position.
(Outlet parallel to joists.)
New construction)
(
12¼"
Mounting brackets mounted
to outlet sides of housing.
(Outlet perpendicular to joists.)
(
New construction)
1
/
8
"
12¼"
Mounting brackets flipped
over and mounted to outlet
sides of housing.
(Outlet parallel to joists.)
(
Existing construction)
12¼"
Mounting brackets flipped
over to give approx. 1”
more clearance.
(Outlet parallel to joists.)
(
New construction)
1½"
to
2½"
1
2
1
/
to
1
/
DUCTING OPTIONS
BLOWER DISCHARGE POSITIONS
DUCT
CONNECTOR
2
"
2
"
BLOWER
Blower and duct connector
straight through dis-
in
charge position.
(Factory shipped)
DUCTING
(Right angle blower discharge)
CONNECTOR
positions for
right angle discharge.
ROOF CAP
DUCT
Change
blower &
duct
connector
BLOWER
Blower and duct connector
right angle discharge
in
position.
1
/
2"
9
to
1
/
2"
10
12¼"
Mounting brackets mounted
to top of sides of housing.
(Outlet parallel to joists.)
(
New or existing construction)
Mounting brackets flipped
over and mounted to top of
sides of housing.
(Outlet parallel to joists.)
(
New or existing construction)
WIRING OPTIONS
WIRING PLATE POSITION
HORIZONTAL POWER
CABLE CONNECTION
Wiring plate mounts to side or top of housing.
12¼"
VERTICAL
POWER
CABLE
CONNECTION
10
11
ROUND
DUCT*
3
/
4
to
3
/
4
Typical ductwork connection to a ventilator converted to
right angle discharge.
* L100L & L150L use 6” round duct.
L200L, L250L, & L300L use 8” round duct.
USE AND CARE
Ventilator is designed for continuous operation. If desired, it may be controlled using an on/off switch or an electronic, variable speed control. Follow wiring instructions packed with control, and adhere to all local and state codes, and the National Electrical Code.
WARNING: To reduce the risk of electric shock, disconnect from power supply before servicing.
To clean blower assembly: Remove access panel, unplug blower
from housing, remove blower mounting nuts, and carefully remove blower from housing. Use appropriate vacuum attachment or a soft cloth and mild soap or detergent to clean blower discharge area and wheel. DO NOT ALLOW WATER TO ENTER MOTOR. Make sure blower assembly is completely dry before reinstalling.
Motor is permanently lubricated. Do not oil or disassemble motor.
L100L • L150L • L200L • L250L • L300L
SERVICE PARTS SERVICE PARTS
MODELS
Page 4
KEY NO. PART NO. DESCRIPTION
1 97014735 Housing Assembly (L100L & L150L)
97014736 Housing Assembly (L200L, L250L, & L300L) 2 97014728 Mounting Bracket (2 req.) 3 97014760 Damper Assembly (6” dia.)
97014761 Damper Assembly (8” dia.) 4 99390098 Duct Connector (6” dia.)
99390099 Duct Connector (8” dia.) 5 99150415 Screw, 8-18 x ¼ (12 req.)* 6 98005513 Wire Box Cover 7 99400035 Strain Relief Bushing 8 98005512 Wiring Plate 9 99150471 Ground Screw, 10-32 x ½ (2 req.)
10 97014774 Scroll Assembly (L100L & L150L)
97014775 Scroll Assembly (L200L, L250L, & L300L)
11 98009399 Inlet Ring 12 99110805 Blower Wheel 13 99080481 Motor (L100L)
99080482 Motor (L150L) 99080483 Motor (L200L) 99080484 Motor (L250L)
99080485 Motor (L300L) 14 99260558 Lock Nut, 8-32 (4 req.)* 15 99250959 Washer (4 req.)* 16 99100491 Grommet (4 req.)
Blower Assembly, Complete
(Includes Key Nos. 5 & 10-17) 97014800 (L100L) 97014801 (L150L) 97014802 (L200L) 97014803 (L250L) 97014804 (L300L)
17 99260477 Nut, ¼-20 (6 req.)* 18 97006039 Wire Harness 19 98009417 Access Panel 20 99420470 Cover Nut (2 req.) 21 99150472 Cover Mounting Screw (2 req.) 22 99150591 Screw, 10-16 x 7/8 (4 req.)*
5
3
8
5
9
2
22
1
5
20
4
22
16
5
6
7
5
18
16
11
12
10
14
15
17
13
BLOWER
ASSEMBLY
19
Order replacement parts by PART NO. - not by KEY NO. * Standard hardware - may be purchased locally.
21
WARRANTY
Broan-NuTone warrants to the original consumer purchaser of its products that such products will be free from defects in materials or workmanship for a period of one year from the date of original purchase. THERE ARE NO OTHER WARRANTIES, EXPRESS OR IMPLIED, INCLUDING, BUT NOT LIMITED TO, IMPLIED WARRANTIES OF MERCHANTABILITY OR FITNESS FOR A PARTICULAR PURPOSE. During this one-year period, Broan-NuTone will, at its option, repair or replace, without charge, any product or part which is found to be defective under normal use and service. THIS WARRANTY DOES NOT EXTEND TO FLUORESCENT LAMP STARTERS AND TUBES. This warranty does not cover (a) normal maintenance and service or (b) any products or parts which have been subject to misuse, negligence, accident, improper maintenance or repair (other than by Broan-NuTone), faulty installation or installation contrary to recommended installation instructions. The duration of an implied warranty is limited to the one-year period as specified for the express warranty. Some states do not allow limitation on how long an implied warranty lasts, so the above limitation may not apply to you. BROAN-NUTONE’S OBLIGATION TO REPAIR OR REPLACE, AT BROAN-NUTONE’S OPTION, SHALL BE THE PURCHASER’S SOLE AND EXCLUSIVE REMEDY UNDER THIS WARRANTY. BROAN-NUTONE SHALL NOT BE LIABLE FOR INCIDENTAL, CONSEQUENTIAL OR SPECIAL DAMAGES ARISING OUT OF OR IN CONNECTION WITH PRODUCT USE OR PERFORMANCE. Some states do not allow the exclusion or limitation of incidental or consequential damages, so the above limitation may not apply to you. This warranty gives you specific legal rights, and you may also have other rights, which vary from state to state. This warranty supersedes all prior warranties. To qualify for warranty service, you must (a) notify Broan-NuTone at the address or phone number stated below (b) give the model number and part identification and (c) describe the nature of any defect in the product or part. At the time of requesting warranty service, you must present evidence of the original purchase date. In the U.S., contact: Broan-NuTone, 926 West State Street, Hartford, WI U.S.A. 53027 (1-800-637-1453) In Canada, contact: Broan-NuTone Canada, 1140 Tristar Drive Mississauga, Ontario L5T 1H9 (1-888-882-7626)
BROAN-NUTONE ONE YEAR LIMITED WARRANTY
99042723H