Broan GSEH3K, GSFH1K, GSVH1K, GSHH3K User Manual

REGISTER YOUR PRODUCT ON LINE AT:
www.broan.com/register
For additional information - visit www.Broan.com
05690 rev. 5
Broan-NuTone LLC 99043224
RESIDENTIAL USE ONLY.
INSTALLER: LEAVE THIS MANUAL WITH CONSUMER.
HEPA Filtration,
Fresh Air and
Heat Recovery
Ventilation*
GSHH3K
*Patents pending
USER MANUAL
HEPA
Filtration*
GSFH1K
HEPA Filtration and
Fresh Air
Ventilation*
GSVH1K
HEPA Filtration,
Fresh Air and
Energy Recovery
Ventilation*
GSEH3K
ABOUT THIS MANUAL
Congratulations! Your purchase of this whole-house HEPA filtration, with optional ventilation will allow you and your family to enjoy clean and healthy air throughout your home for years to come! Please read this booklet thoroughly. Several models are described in this publication. Some details of your unit may be slightly different than the ones shown, as the illustrations are typical ones.
This manual uses the following symbols to emphasize particular information:
NOTE: Indicates supplementary information needed to fully complete an instruction. We welcome any suggestions concerning this manual and/or the product, or ways
to better serve you. Please forward all correspondence at the address below:
Broan-NuTone LLC
Indoor Air Quality Mkt.
926 W. State St.,
Hartford, WI 53027
WARNING
Identifies an instruction which, if not followed, might cause serious personal injuries including possibility of death.
!
CAUTION
Denotes an instruction which, if not followed, may severely damage the unit and/or its components.
CAUTION
Your unit may be installed in a non heated area (e.g.: attic). In this case, your unit must run all the time if the outside temperature is too cold (32°F or below). A GSHH3K unit or a GSEH3K unit must be protected from freezing with an insulation blanket or a duct board insulated enclosure. See installation manual.
CAUTION
The GSVH1K, GSHH3K and GSEH3K units are not dehumidifiers. During cooling season, when high humidity weather occurs, it is preferable to momentarily stop the air exchange with the outside, until the period of excessive humidity passes. This will prevent too much humidity from entering the home. To stop the air exchange with a GSVH1K, set its wall controller to OFF. To stop the air exchange with a GSHH3K or a GSEH3K, set its wall controller to RECIRCULATION (the unit will continue to filter the inside air).
- 2 -
NOTE: The energy recovery ventilator GSEH3K is designed to assist in the
management of humidity introduced into the home. In extreme humidity conditions, the use of additional dehumidification may be desirable. Quickly remove all excess moisture and keep areas clean.
1.0 ABOUT THESE UNITS .................................................4
2.0 CONTROLS............................................................5-8
2.1 Main Switch.....................................................................5
2.2 Operating ACCGSC1 Controller .....................................5
2.3 Operating 40425 Controller .........................................6-8
3.0 MAINTENANCE .....................................................9-12
3.1 Semi-annual Maintenance .........................................9-11
3.2 Annual Maintenance .....................................................11
3.3 Optional Alpine/pine Filter.............................................12
4.0 TROUBLESHOOTING.................................................13
5.0 W
ARRANTY ............................................................14
TABLE OF CONTENTS
- 3 -
- 4 -
1. ABOUT THESE UNITS
WARNING
TO REDUCE THE RISK OF FIRE, ELECTRIC SHOCK, OR INJURY TO PERSON(S) OBSERVE THE FOLLOWING:
1. This unit is intented for residential installation only.
2. Installation must be done in accordance with all applicable codes and standards, including fire-rated construction codes and standards.
3. This unit is not designed to provide combustion and/or dilution air for fuel-burning appliances.
4. Do not install in a cooking area or connect directly to an appliance.
5. Before replacing filters, servicing or cleaning unit, disconnect the power cord from the electrical outlet.
6. When cutting or drilling into the wall or ceiling, do not damage electrical wiring or other hidden utilities.
7. Do not use this unit with any solid-state speed control device other than wall controls ACCGSC1 or 40425, provided with the unit.
8. This unit must be grounded. The power supply cord has a 3-prong grounding plug for your personal safety. It must be plugged into a mating 3-prong grounding receptacle, grounded in accordance with the national electrical code and local codes and ordinances. Do not remove the ground prong. Do not use an extension cord.
9. This unit must be installed in a weatherized location out of direct sunlight and protected from the elements.
10. Use this unit only in the manner intended by the manufacturer. If you have questions, contact the manufacturer at the address or telephone number listed in this document.
11. When cleaning the unit, it is recommended to wear safety glasses and gloves.
!
CAUTION
1. For general ventilating use only. Do not use to exhaust hazardous or explosive materials and vapors.
2. Intended for residential installation in accordance with the requirements of NFPA 90B.
3. For GSVH1K, GSHH3K and GSEH3K units only: Be sure to duct air outside. Do not intake / exhaust air into spaces within walls or ceiling or into attics, crawl spaces, or garage.
4. Do not run any air ducts directly above or closer than 2 ft (0.61 m) to any furnace or its supply plenum, boiler, or other heat producing appliance. If a duct has to be connected to the furnace return plenum, it must be connected not closer than 2 ft (0.61 m) from this plenum connection to the furnace.
5. The ductwork is intended to be installed in compliance with all local and national codes that are applicable.
6. To avoid prematurate clogged filters, turn OFF the unit during construction or renovation.
7. At least once in a year, the unit mechanical and electronic parts should be inspected by qualified service personnel.
8. Please read the unit specification label on the product for further information and requirements.
2.2 OPERATING ACCGSC1 CONTROLLER
2.2.1 ACCGSC1 CONTROLLER DESCRIPTION
2.2.2 USING ACCGSC1 CONTROLLER
• OFF: To stop the unit, slide the button on this position.
• LOW: For a day-to-day usage, slide the button on this position. The unit then will operate on low speed, providing 70 cfm.
• H
IGH: For a high speed operation, slide the button on this position.
Generally used when more ventilation is required, such as parties, smokers, or for a 6-bedroom house. This mode provides 105 cfm.
2. CONTROLS
POWER INDICATOR:
LIGHTS UP WHEN SLIDE
SWITCH IS IN THE HIGH OR
LOW POSITION.
FILTER MAINTENANCE
INDICATOR:
FLASHES EVERY MINUTE TO
INDICATE IT IS ON DUTY.
FLASHES EVERY SECOND
WHEN IT IS TIME TO
REPLACE PREFILTER.
LED STAYS LIT WHEN IT IS
TIME TO REPLACE FILTER
AND PREFILTER
.
RESET FILTER HOLE:
ONCE THE MAINTENANCE DONE, RESET THE FILTER
MAINTENANCE INDICATOR BY CAREFULLY INSERTING A SMALL ROD
(E.G.: PAPER CLIP) IN THE RESET FILTER HOLE,
FOR 1 SECOND. THE FILTER MAINTENANCE INDICATOR WILL TURN OFF. REFER TO THE FILTER MAINTENANCE RECOMMENDATIONS IN SECTION 3.
- 5 -
OFF:
UNIT IS OFF.
Low:
UNITISOPERATINGAT
ITS LOW SPEED.
HIGH:
UNITISOPERATINGAT
ITS HIGH SPEED.
2.1 MAIN SWITCH
All units are equipped with a 3-position main switch, located on the front panel. The unit is intented for use with a wall controller (provided, see below). The main switch is to remain in either the “OFF” or “Normal/Remote” modes ONLY. The “Normal/Remote” mode allows the homeowner to operate the product from the wall controller (supplied with the unit), typically mounted near a thermostat or other convenient location.
OFF:
UNIT IS OFF AND
DOOR IS
UNLOCKED.
NORMAL/REMOTE: UNITISOPERATINGON
LOW SPEED
. THIS IS THE
CORRECT POSITION WHEN THE WALL CONTROLLER IS USED.
BOOST:
UNIT IS OPERATING
ON HIGH SPEED.
VC0053
Power
High
Low
Filter Maintenance
VC0059
OFF
Reset Filter
Loading...
+ 9 hidden pages