HEPA Filtration,
Fresh Air and
Heat Recovery
Ventilation*
GSHH3K
*Patents pending
USER MANUAL
HEPA
Filtration*
GSFH1K
HEPA Filtration and
Fresh Air
Ventilation*
GSVH1K
HEPA Filtration,
Fresh Air and
Energy Recovery
Ventilation*
GSEH3K
VB0061
ABOUT THIS MANUAL
Congratulations! Your purchase of this whole-house HEPA filtration, with optional
ventilation will allow you and your family to enjoy clean and healthy air throughout
your home for years to come!
Please read this booklet thoroughly.
Several models are described in this publication. Some details of your unit may be
slightly different than the ones shown, as the illustrations are typical ones.
This manual uses the following symbols to emphasize particular information:
NOTE: Indicates supplementary information needed to fully complete an instruction.
We welcome any suggestions concerning this manual and/or the product, or ways
to better serve you. Please forward all correspondence at the address below:
Broan-NuTone LLC
Indoor Air Quality Mkt.
926 W. State St.,
Hartford, WI 53027
WARNING
Identifies an instruction which, if not followed, might cause serious
personal injuries including possibility of death.
CAUTION
Denotes an instruction which, if not followed, may severely damage the unit
and/or its components.
CAUTION
Your unit may be installed in a non heated area (e.g.: attic). In this case, your
unit must run all the time if the outside temperature is too cold (32°F or below).
A GSHH3K unit or a GSEH3K unit must be protected from freezing with an
insulation blanket or a duct board insulated enclosure. See installation manual.
CAUTION
The GSVH1K, GSHH3K and GSEH3K units are not dehumidifiers. During
cooling season, when high humidity weather occurs, it is preferable to
momentarily stop the air exchange with the outside, until the period of
excessive humidity passes. This will prevent too much humidity from entering
the home. To stop the air exchange with a GSVH1K, set its wall controller to
OFF. To stop the air exchange with a GSHH3K or a GSEH3K, set its wall
controller to RECIRCULATION (the unit will continue to filter the inside air).
- 2 -
NOTE: The energy recovery ventilator GSEH3K is designed to assist in the
management of humidity introduced into the home. In extreme humidity
conditions, the use of additional dehumidification may be desirable.
Quickly remove all excess moisture and keep areas clean.
1.0 ABOUT THESE UNITS .................................................4
2.0 CONTROLS............................................................5-8
2.1 Main Switch.....................................................................5
2.2 Operating ACCGSC1 Controller .....................................5
2.3 Operating 40425 Controller .........................................6-8
3.0 MAINTENANCE .....................................................9-12
3.1 Semi-annual Maintenance .........................................9-11
3.2 Annual Maintenance .....................................................11
3.3 Optional Alpine/pine Filter.............................................12
4.0 TROUBLESHOOTING.................................................13
5.0 W
ARRANTY ............................................................14
TABLE OF CONTENTS
- 3 -
- 4 -
1. ABOUT THESE UNITS
WARNING
TO REDUCE THE RISK OF FIRE, ELECTRIC SHOCK, OR INJURY TO
PERSON(S) OBSERVE THE FOLLOWING:
1. This unit is intented for residential installation only.
2. Installation must be done in accordance with all applicable codes and
standards, including fire-rated construction codes and standards.
3. This unit is not designed to provide combustion and/or dilution air for
fuel-burning appliances.
4. Do not install in a cooking area or connect directly to an appliance.
5. Before replacing filters, servicing or cleaning unit, disconnect the power
cord from the electrical outlet.
6. When cutting or drilling into the wall or ceiling, do not damage electrical wiring
or other hidden utilities.
7. Do not use this unit with any solid-state speed control device other than
wall controls ACCGSC1 or 40425, provided with the unit.
8. This unit must be grounded. The power supply cord has a 3-prong grounding
plug for your personal safety. It must be plugged into a mating 3-prong
grounding receptacle, grounded in accordance with the national electrical code
and local codes and ordinances. Do not remove the ground prong. Do not
use an extension cord.
9. This unit must be installed in a weatherized location out of direct sunlight
and protected from the elements.
10. Use this unit only in the manner intended by the manufacturer. If you
have questions, contact the manufacturer at the address or telephone number
listed in this document.
11. When cleaning the unit, it is recommended to wear safety glasses and gloves.
CAUTION
1. For general ventilating use only. Do not use to exhaust hazardous or explosive
materials and vapors.
2. Intended for residential installation in accordance with the requirements of
NFPA 90B.
3. For GSVH1K, GSHH3K and GSEH3K units only: Be sure to duct air outside.
Do not intake / exhaust air into spaces within walls or ceiling or into attics,
crawl spaces, or garage.
4. Do not run any air ducts directly above or closer than 2 ft (0.61 m) to any furnace
or its supply plenum, boiler, or other heat producing appliance. If a duct has
to be connected to the furnace return plenum, it must be connected not
closer than 2 ft (0.61 m) from this plenum connection to the furnace.
5. The ductwork is intended to be installed in compliance with all local and
national codes that are applicable.
6. To avoid prematurate clogged filters, turn OFF the unit during construction
or renovation.
7. At least once in a year, the unit mechanical and electronic parts should be
inspected by qualified service personnel.
8. Please read the unit specification label on the product for further information
and requirements.
2.2 OPERATING ACCGSC1 CONTROLLER
2.2.1 ACCGSC1 CONTROLLER DESCRIPTION
2.2.2 USING ACCGSC1 CONTROLLER
• OFF: To stop the unit, slide the button on this position.
• LOW: For a day-to-day usage, slide the button on this position.
The unit then will operate on low speed, providing 70 cfm.
• H
IGH: For a high speed operation, slide the button on this position.
Generally used when more ventilation is required, such as parties,
smokers, or for a 6-bedroom house. This mode provides 105 cfm.
2. CONTROLS
POWER INDICATOR:
LIGHTS UP WHEN SLIDE
SWITCH IS IN THE HIGH OR
LOW POSITION.
FILTER MAINTENANCE
INDICATOR:
FLASHES EVERY MINUTE TO
INDICATE IT IS ON DUTY.
FLASHES EVERY SECOND
WHEN IT IS TIME TO
REPLACE PREFILTER.
LED STAYS LIT WHEN IT IS
TIME TO REPLACE FILTER
AND PREFILTER
.
RESET FILTER HOLE:
ONCE THE MAINTENANCE DONE, RESET THE FILTER
MAINTENANCE INDICATOR BY CAREFULLY INSERTING A SMALL
ROD
(E.G.: PAPER CLIP) IN THE RESET FILTER HOLE,
FOR 1 SECOND. THE FILTER MAINTENANCE INDICATOR
WILL TURN OFF. REFER TO THE FILTER MAINTENANCE
RECOMMENDATIONS IN SECTION 3.
- 5 -
OFF:
UNIT IS OFF.
Low:
UNITISOPERATINGAT
ITS LOW SPEED.
HIGH:
UNITISOPERATINGAT
ITS HIGH SPEED.
2.1 MAIN SWITCH
All units are equipped with a 3-position main switch, located on the front panel. The
unit is intented for use with a wall controller (provided, see below). The main switch
is to remain in either the “OFF” or “Normal/Remote” modes ONLY. The “Normal/Remote”
mode allows the homeowner to operate the product from the wall controller (supplied
with the unit), typically mounted near a thermostat or other convenient location.
OFF:
UNIT IS OFF AND
DOOR IS
UNLOCKED.
NORMAL/REMOTE:
UNITISOPERATINGON
LOW SPEED
. THIS IS THE
CORRECT POSITION
WHEN THE WALL
CONTROLLER IS USED.
BOOST:
UNIT IS OPERATING
ON HIGH SPEED.
VC0053
Power
High
Low
Filter Maintenance
VC0059
OFF
Reset Filter