Broan EW4324SS, EW4330SS, EW4330BLS, EW4336SS, EW4336BLS INSTALLATION INSTRUCTIONS AND OPERATION MANUAL

WWW.BROAN.COM WWW.BROAN.CA
WW.BR
CHIMNEY
EW43 Series
INSTALLATION, USE
AND CARE MANUAL
Serial number:
99046142C
! !
INTENDED FOR DOMESTIC COOKING ONLY
READ AND SAVE THESE INSTRUCTIONS
INSTALLER: LEAVE THIS MANUAL WITH HOMEOWNER.
HOMEOWNER: USE AND CARE INFORMATION ON PAGE 10.
In U.S.A., register your range hood online at www.broan.com
In Canada, register your range hood online at www.broan.ca
!
WARNING
TO REDUCE THE RISK OF FIRE, ELECTRIC SHOCK OR INJURY TO PERSONS, OBSERVE THE FOLLOWING:
1. Use this unit only in the manner intended by the manufacturer.
If you have questions, contact the manufacturer at the address or telephone number listed in the warranty.
2. Before servicing or cleaning unit, switch power off at service
panel and lock service disconnecting means to prevent power from being switched on accidentally. When the service disconnecting means cannot be locked, securely fasten a prominent warning device, such as a tag, to the service panel.
3. Installation work and electrical wiring must be done by
qualified personnel in accordance with all applicable codes and standards, including fire-rated construction codes and standards.
4. Sufficient air is needed for proper combustion and exhausting
of gases through the flue (chimney) of fuel burning equipment to prevent backdrafting. Follow the heating equipment manufacturer’s guidelines and safety standards such as those published by the National Fire Protection Association (NFPA) and the American Society for Heating, Refrigeration and Air Conditioning Engineers (ASHRAE) and the local code authorities.
5. When cutting or drilling into wall or ceiling, do not damage
electrical wiring and other hidden utilities.
6. Ducted fans must always be vented to the outdoors.
7. Do not use this unit with any solid-state speed control device.
8. To reduce the risk of fire, use only metal ductwork.
9. This unit must be grounded.
10. When applicable local regulations comprise more restrictive
installation and/or certification requirements, the aforementioned requirements prevail on those of this document and the installer agrees to conform to these at his own expense.
TO REDUCE THE RISK OF A RANGE TOP GREASE FIRE:
a) Never leave surface units unattended at high settings. Boilovers
cause smoking and greasy spillovers that may ignite. Heat oils slowly on low or medium settings.
b) Always turn hood ON when cooking at high heat or when
flambeing food (i.e.: Crêpes Suzette, Cherries Jubilee, Peppercorn Beef Flambé).
c) Clean ventilating fans frequently. Grease should not be allowed
to accumulate on fan, filters or in exhaust ducts.
d) Use proper pan size. Always use cookware appropriate for the
size of the surface element.
!
WARNING
TO REDUCE THE RISK OF INJURY TO PERSONS IN THE EVENT OF A RANGE TOP GREASE FIRE, OBSERVE THE FOLLOWING*:
1. SMOTHER FLAMES with a close-fitting lid, cookie sheet or
metal tray, then turn off the burner. BE CAREFUL TO PREVENT BURNS. IF THE FLAMES DO NOT GO OUT IMMEDIATELY, EVACUATE AND CALL THE FIRE DEPARTMENT.
2. NEVER PICK UP A FLAMING PAN — You may be burned.
3. DO NOT USE WATER, including wet dishcloths or towels —
This could cause a violent steam explosion.
4. Use an extinguisher ONLY if: A. You own a Class ABC extinguisher and you know how to
operate it.
B. The fire is small and contained in the area where it started. C. The fire department has been called. D. You can fight the fire with your back to an exit.
* Based on “Kitchen Fire Safety Tips” published by NFPA.
CAUTION
1. For indoor use only.
2. For general ventilating use only. Do not use to exhaust
hazardous or explosive materials and vapors.
3. To avoid motor bearing damage and noisy and/or unbalanced
impeller, keep drywall spray, construction dust, etc. off power unit.
4. Your hood motor has a thermal overload which will automatically
shut off the motor if it becomes overheated. The motor will restart when it cools down. If the motor continues to shut off and restart, have the hood serviced.
5. The minimum hood distance above cooktop must not be less
than 24". For best capture of cooking impurities, the bottom of the hood should be at a maximum of 30" above cooking surface.
6. Two installers are recommended because of the large size and
weight of this unit.
7. To reduce the risk of fire and to properly exhaust air, be sure to
duct air outside — Do not exhaust air into spaces within walls or ceiling or into attics, crawl space or garage.
8. Because of the high exhausting capacity of this unit, you
should make sure enough air is entering the house to replace exhausted air by opening a window close to or in the kitchen.
9. To reduce the risk of fire and electrical shock, the Broan Elite
EW43 Series models should only be installed with their own built-in blower.
10. When used in recirculation mode, to reduce the risk of fire and
shock, use only conversion kit model ARKEW43.
11. Please read specification label on product for further information
and requirements.
2
TABLE OF CONTENTS
!
1. P REPARE INSTALLATION. . . . . . . . . . . . . . . . . . . . . . . . . . . . 3
2. SELECT INSTALLATION TYPE . . . . . . . . . . . . . . . . . . . . . . . . . 3
3. BUILD FRAMEWORK . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4
4 I
NSTALL UPPER FLUE MOUNTING BRACKET
(DUCTED INSTALLATION ONLY). . . . . . . . . . . . . . . . . . . . . . . . 4
5. INSTALL PLENUM (NON-DUCTED INSTALLATION ONLY) . . . . . . . . . 4
6. REMOVE GREASE FILTER(S). . . . . . . . . . . . . . . . . . . . . . . . . 5
7. A DJUST THE HOOD MOUNTING BRACKETS . . . . . . . . . . . . . . . . 5
8. INSTALL THE HOOD. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 5
ONECT WIRING . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 6
9. C
10. DUCT CONNECTION . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 7
11. PREPARE THE DECORATIVE FLUE. . . . . . . . . . . . . . . . . . . . . . 8
12. I
NSTALL THE DECORATIVE FLUE. . . . . . . . . . . . . . . . . . . . . 8-9
13. REINSTALL GREASE FILTER(S) . . . . . . . . . . . . . . . . . . . . . . . 9
14. OPERATION . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 10
15. CARE . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 10
16. REPLACEMENT PA R TS . . . . . . . . . . . . . . . . . . . . . . . . . . . . 11
17. WARRANTY . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 12
1. PREPARE INSTALLATION
NOTE: Before proceeding to the installation, check the contents of the box. If items are missing or damaged, contact the retailer. Make sure that the following items are included:
- Hood
- Decorative flue assembly (lower and upper flues)
- Upper flue mounting bracket
- Aluminum grease filter(s) (1 for 24-in. width hood, 2 for 30-in. and 36-in. width hoods)
- Installation instructions
- Parts bag: 6 M4 x 38 Phillips round head mounting screws, 2 M4 x 12 Phillips round head screws, 2 washers, 3 wire connectors
Parts sold separately:
- Ducts, elbows, wall and roof caps.
- Optional flue extension for ceilings of 9 ft. or more: models AEEW43SS (stainless
steel) or AEEW43BLS (black stainless steel).
- Non-duct kit model ARKEW43, mandatory for non-ducted installation.
NOTE: During installation, protect countertop and/or cooktop.
(1) DECORATIVE FLUE ASSEMBLY
HR0225A
(1) UPPER FLUE
MOUNTING
(1 OR 2) GREASE FILTER(S)
X 38 PHILLIPS
(6) M4
ROUND HEAD SCREWS
(2) M4
X 12 PHILLIPS
ROUND HEAD SCREWS
(2) WASHERS
(3) WIRE CONNECTORS
BRACKET
2. SELECT INSTALLATION TYPE
WARNING
When performing installation, servicing or cleaning the unit, it is recommended to wear safety glasses and gloves.
2.1 NON-DUCTED INSTALLATION
The ARKEW43 non-duct kit is required for a non-ducted installation.
2.2 DUCTED INSTALLATION
Plan where and how the ductwork will be installed.
A straight, short duct run will allow the hood to perform most efficiently. Long duct runs, elbows and transitions will reduce the performance of the hood. Use as few of them as possible. Larger ducting may be required for longer duct runs.
Install wall or roof cap. Connect 6” round metal ductwork to cap and work back towards the hood location. Use 2” metal foil duct tape to seal the joints.
2.3 ALL INSTALLATIONS
The minimum hood distance above cooktop is 24”. A maximum of 30” above cooktop is recommended for best capture of cooking impurities.
Distances over 30” are at the installer and users discretion providing that ceiling
height and decorative flue length allow it. NOTE: Ceilings of 9 ft. or more require flue extension model AEEW43SS (stainless
steel) or AEEW43BLS (black stainless steel).
3
DECORATIVE
HH0282A
ROOF CAP
FLUE
HOOD
24” MINIMUM ABOVE
SURFACE
COOKING
6” ROUND
DUCT
WALL
CAP
6” ROUND
ELBOW
3. BUILD FRAMEWORK
!
WARNING
• When cutting or drilling into wall, do not damage electrical wiring and other hidden utilities.
• When building framework, always follow all applicable construction codes and standards.
WALL STUDS
Construct wood wall framing that is even with the surface of wall studs. Wood wall framing must be at least 1/2” thick and 3” high. Fasten wood wall framing to wall studs for a solid installation. Make sure that the height of the framing will allow the retaining screws to be secured to the framing within the dimensions shown. After wall surface is finished, using a level, draw a vertical line up to the ceiling starting from the center of the planned hood location. Measure and mark the retaining screw locations using the measurements given in illustration at right. Insert 2 M4 x 38 Phillips round head mounting screws in wall framing; do not completely tighten the screws at this time.
HD1152A
35” = BOTTOM OF HOOD 24” ABOVE COOKTOP 41” = BOTTOM OF HOOD 30” ABOVE COOKTOP
FRAMING BEHIND DRYWALL
4. INSTALL UPPER FLUE MOUNTING BRACKET (DUCTED INSTALLATION ONLY)
Center the upper flue mounting bracket with the center line previously drawn in step 3 and place it flush with the ceiling. Use the upper flue mounting bracket as a template to mark the position of its screws.
Secure the upper flue bracket to the wall using 2 M4 x 38 Phillips round head mounting screws. Make sure that the bracket is tight against the wall.
CEILING
UPPER FLUE MOUNTING
HD1154
CENTER OF INSTALLATION
BRACKET SLOTS
C
L
MOUNTING BRACKET
FLUSH WITH CEILING
5. INSTALL PLENUM (NON-DUCTED INSTALLATION ONLY)
CEILING
Center the plenum (included in the non-duct kit) with the center line previously drawn in step 3 and place it flush with the ceiling. Use the plenum mounting slots as a template to mark the position of its screws.
Secure the plenum to the wall using 2 M4 x 38 Phillips round head mounting screws. Make sure that the plenum is tight against the wall.
HD1158
4
PLENUM
MOUNTING
SLOTS
FLUSH WITH
C
CENTER OF
L
INSTALLATION
PLENUM
CEILING
Loading...