Broan E6036ss, E6042tss, E6030ss, E6048tss, E60e30ss Installation Guide

...
E60000 SERIES
INTENDED FOR DOMESTIC COOKING ONLY
INSTALLER: LEAVE THIS MANUAL WITH HOMEOWNER.
HOMEOWNER: USE AND CARE INFORMATION ON PAGE 13 AND 14.
Broan-NuTone LLC; Hartford, Wisconsin www.broan.com 800-558-1711 Broan-NuTone Canada; Mississauga, Ontario www.broan.ca 877-896-1119
REGISTER YOUR PRODUCT ON LINE AT: www.broan.com/register
SV08340 rev. C
INSTALLATION INSTRUCTIONS
READ AND SAVE THESE INSTRUCTIONS
!
!
- 2 -
TO REDUCE THE RISK OF FIRE, ELECTRIC SHOCK OR INJURY TO PERSONS, OBSERVE THE FOLLOWING:
1. Use this unit only in the manner intended by the
manufacturer. If you have questions, contact the manufacturer at the address or telephone number listed in the warranty.
2. Before servicing or cleaning unit, switch power
off at service panel and lock service disconnecting means to prevent power from being switched on accidentally. When the service disconnecting means cannot be locked, securely fasten a prominent warning device, such as a tag, to the service panel.
3. Installation work and electrical wiring must be
done by qualified personnel in accordance with all applicable codes and standards, including fire-rated construction codes and standards.
4. Sufficient air is needed for proper combustion and
exhausting of gases through the flue (chimney) of fuel burning equipment to prevent backdrafting. Follow the heating equipment manufacturer’s guidelines and safety standards such as those published by the National Fire Protection Association (NFPA), and the American Society for Heating, Refrigeration and Air Conditioning Engineers (ASHRAE), and the local code authorities.
5. When cutting or drilling into wall or ceiling, do not
damage electrical wiring and other hidden utilities.
6. Ducted fans must always be vented to the outdoors.
7. Do not use this unit with any additional solid-state
speed control device.
8. To reduce the risk of fire, use only steel ductwork.
9. This unit must be grounded.
10.
When applicable local regulations comprise more restrictive installation and/or certification requirements, the aforementioned requirements prevail on those of this document and the installer agrees to conform to these at his own expenses
TO REDUCE THE RISK OF A RANGE TOP GREASE FIRE:
a) Never leave surface units unattended at high settings.
Boilovers cause smoking and greasy spillovers that may ignite. Heat oils slowly on low or medium settings.
b) Always turn hood ON when cooking at high heat or
when flambeing food (i.e.: Crêpes Suzette, Cherries Jubilee, Peppercorn Beef Flambé).
c) Clean ventilating fans frequently. Grease should
not be allowed to accumulate on fan or filter.
d) Use proper pan size. Always use cookware
appropriate for the size of the surface element.
TO REDUCE THE RISK OF INJURY TO PERSONS IN THE EVENT OF A RANGE TOP GREASE FIRE, OBSERVE THE FOLLOWING*:
1. SMOTHER FLAMES with a close-fitting lid, cookie
sheet or metal tray, then turn off the burner. BE CAREFUL TO PREVENT BURNS. IF THE FLAMES DO NOT GO OUT IMMEDIATELY, EVACUATE AND CALL THE FIRE DEPARTMENT.
2. NEVER PICK UP A FLAMING PAN—You may be
burned.
3. DO NOT USE WATER, including wet dishcloths or
towels—This could cause a violent steam explosion.
4. Use an extinguisher ONLY if: A. You own a Class ABC extinguisher and you
know how to operate it.
B. The fire is small and contained in the area
where it started.
C. The fire department has been called. D. You can fight the fire with your back to an exit.
* Based on “Kitchen Fire Safety Tips” published by NFPA.
CAUTION
1. For indoor use only.
2. For general ventilating use only. Do not use to
exhaust hazardous or explosive materials and vapors.
3. To avoid motor bearing damage and noisy and/or
unbalanced impellers, keep drywall spray, construction dust, etc. off power unit.
4. Your hood motor has a thermal overload which will
automatically shut off the motor if it becomes overheated. The motor will restart when it will be cooled down. If the motor continues to shut off and restart, have the hood serviced.
5. For best capture of cooking impurities, the bottom of
the hood should be at a minimum of 24” and at a maximum of 30” above the cooking surface.
6. Two installers are recommended because of the
large size and weight of this hood.
7. To reduce the risk of fire and to properly exhaust air,
be sure to duct air outside—Do not exhaust air into spaces within walls or ceiling or into attics, crawl space or garage.
8. This product is equipped with a thermostat which
may start blower automatically. To reduce the risk of injury and to prevent power from being switched on accidentally, switch power off at service panel and lock or tag service panel.
9. Because of the high exhausting capacity of this
hood, you should make sure enough air is entering the house to replace exhausted air. Use an appropriate make-up air device or open a window close to or in the kitchen.
10. To reduce the risk of fire and electric shock, the
Broan Elite E60E Series hood must be installed with one Broan exterior blower model 331H, 332H, 335 or 336; or one Broan in-line blower model HLB3, HLB6, HLB9, HLB11. Other blowers cannot be substituted. (Exterior or in-line blowers sold separately.)
11. Please read specification label on product for further
information and requirements.
WARNING WARNING
!
!
- 3 -
RMP SERIES BACKSPLASH
(STAINLESS STEEL WALL
COVERING WITH WARMING SHELVES
. OPTIONAL)
MODEL 427
(4½” X 18½”
TO 10” ROUND,
6” HIGH - LATERAL
MODEL 423
(4½” X 18½”
TO 10” ROUND -
VERTICAL
MODEL 424
(4½” X 18½”
TO 10” ROUND -
HORIZ. FRONT/REAR
MODEL 454
(4½” X 18½”
TO 10” ROUND -
HORIZ. /RIGHT
MODEL 453
(4½” X 18½”
TO 10” ROUND -
HORIZ. /LEFT
E60000 SERIES HOOD
OPTIONAL
NON-DUCTED RECIRCULATION KIT
ANKE60 SERIES
- E60000 SERIES RANGE HOOD SYSTEM -
INTERNAL BLOWERS
MODEL 437
(H
IGH CAPACITY ROOF CAP)
M
ODEL 441
(10’’ R
OUND WALL CAP)
M
ODEL 410
(10”
ROUND DUCT
—2 FT. SECTIONS)
M
ODEL 418
(10” ROUND ADJUSTABLE ELBOW)
OPTIONAL DECORATIVE
FLUE AEE SERIES
MODEL 421
(10” R
OUND VERTICAL
IN-LINE DAMPER)
8” R
OUND
ADJUSTABLE
ELBOW
MODEL 412 TRANSITION
(3¼” X 10” TO 7”)
STANDARD
DUCT
(3¼” X 10”)
M
ODEL 647
(7” ROUND WALL CAP)
MODEL 634 OR 644
(ROOF CAP)
MODEL 643
(8” ROUND WALL CAP)
8” R
OUND
STANDARD DUCT
MODEL 407
(7” ROUND
—2 FT. SECTIONS)
M
ODEL 413
TRANSITION
(3¼” X 10” TO 8”)
M
ODEL 639
(3¼” X 10” WALL CAP)
M
ODEL 415
(7” ROUND
ADJUSTABLE ELBOW )
A
DAPTER/DAMPER 3¼’’ X 10’’
(SUPPLIED WITH
SINGLE BLOWER HOOD)
A
DAPTER 4½” X 18½”
(SUPPLIED WITH
DOUBLE BLOWER HOOD)
DUAL BLOWER (1200 CFM)
42” AND 48” ONLY
SINGLE BLOWER (600 CFM)
HL0099
- 4 -
HL0100
- E60000 SERIES RANGE HOOD SYSTEM -
IN-LINE AND EXTERIOR BLOWERS
RMP SERIES BACKSPLASH
(STAINLESS STEEL WALL COVERING
WITH WARMING SHELVES.
OPTIONAL)
E60000 SERIES HOOD
332KR IN-LINE AND EXTERIOR BLOWER ROUGH-IN KIT (SUPPLIED WITH HOOD)
M
ODEL 418
10” ROUND
ADJUSTABLE ELBOW
MODEL HLB3 (280 CFM)
IN-LINE BLOWER
(INCLUDES ONE 8” TO 10”
ROUND TRANSITION)
MODEL 331H (600 CFM)
OR 332H (900 CFM)
EXTERIOR BLOWER
MODEL 335 (1200 CFM)
OR 336 (1500 CFM)
EXTERIOR BLOWER
MODEL 441 (10” ROUND WALL CAP)
M
ODEL 437
(HIGH CAPACITY ROOF CAP)
MODEL 441
(10” ROUND WALL CAP)
M
ODEL 421
(10” ROUND VERT. IN-LINE DAMPER) RECOMMENDED FOR
USE WITH EXTERIOR BLOWERS
MODEL 410 (10” ROUND DUCT
- 2FT. SECTIONS)
M
ODEL HLB6 (600 CFM)
IN-LINE BLOWER
(INCLUDES TWO 4½” X 18½” TO
10’’ ROUND TRANSITIONS)
MODEL HLB9 (800 CFM)
OR HLB11 (1100 CFM)
IN-LINE BLOWER
(INCLUDES TWO 8” X 12” TO
10’’ ROUND TRANSITIONS)
M
ODEL 643
(8” ROUND
WALL CAP)
- 5 -
1. SELECT BLOWER OPTION AND INSTALLATION TYPE
1.2 DUCTED INSTALLATION
The Broan Elite E60000 Series range hood includes many configurations: hoods with single or double internal blowers (included with the hood), or hoods using external blowers. For this last category, the Broan Elite E60000 Series must be installed with in-line blower models HLB3, HLB6, HLB9 or HLB11, or exterior blower model 331H, 332H, 335 or 336 only. Other blowers cannot be substituted. (Blowers sold separately).
Plan where and how the ductwork will be installed.
If installing in-line blower, refer to instructions packed with in-line blower and follow steps 1, 2, 3, 4, 6, 10, 12 and up of this manual.
Install proper-sized ductwork, elbows and roof or wall cap for the type of blower you are installing. If using 7”, 8” or 10” round ducts, use a transition (internal blowers only). Use 2” duct tape to seal duct joints.
ROOF CAP
7 or 8” ROUND
OR 3¼ x 10
RECTANGULAR
ELBOW
24 TO 30 ABOVE
COOKING SURFACE
WALL CAP
HOOD
DECORATIVE FLUE
or SOFFIT
HH0088A
7 or 8” ROUND
OR 3¼ x 10 DUCT
12
ONE INTERNAL BLOWER
TYPICAL DUCTWORK
10 ROUND DUCT
x 18½
TO 10
ROUND
TRANSITION
(see page 3)
ROOF CAP
24 TO 30 ABOVE
COOKING SURFACE
WALL CAP
HOOD
DECORATIVE FLUE
or SOFFIT
HH0089A
12
TWO INTERNAL BLOWERS
TYPICAL DUCTWORK
HH0090A
10 ROUND
DUCT
12
EXTERIOR
BLOWER
HOOD
DECORATIVE FLUE
OR SOFFIT
24 TO 30 ABOVE
COOKING SURFACE
332KR
ROUGH-IN KIT
(see page 4)
10 ROUND
ELBOW
EXTERIOR BLOWER
MODEL 331H, 332H, 335 OR 336
EXTERIOR BLOWER TYPICAL DUCTWORK
HH0091A
24 TO 30
ABOVE COOKING SURFACE
IN-LINE BLOWER
10 ROUND DUCT
(except HLB3, 8’’ ROUND DUCT)
ROOF CAP
WALL CAP
HOOD
MODEL HLB3, HLB6, HLB9 OR HLB11
IN-LINE BLOWER TYPICAL DUCTWORK
1.1 NON-DUCTED INSTALLATION
For a non-ducted installation, a recirculation kit ANKE60 Series (sold separately) must be installed. For maximum effectiveness, we recommend installing this kit with a single (internal) blower hood. The kit fits hood from 30-inch width up to 48-inch width. See installation instructions included with the non-duct kit ANKE60 Series.