Broan BUEZ3 User Manual

BUEZ3 SERIES RANGE HOOD
READ AND SAVE THESE INSTRUCTIONS
!
INTENDED FOR DOMESTIC COOKING ONLY
WARNING
TO REDUCE THE RISK OF FIRE, ELECTRIC SHOCK, OR INJURY TO PERSONS, OBSERVE THE FOLLOWING:
1. Use this unit only in the manner intended by the manufacturer. If you have questions, contact the manufacturer at the address or telephone number listed in the warranty.
2. Before servicing or cleaning unit, switch power off at service panel and lock service panel to prevent power from being switched on accidentally. When the service disconnecting means cannot be locked, securely fasten a prominent warning device, such as a tag, to the service panel.
3. Installation work and electrical wiring must be done by a qualified person(s) in accordance with all applicable codes and standards.
4. Sufficient air is needed for proper combustion and exhausting of gases through the flue (chimney) of fuel burning equipment to prevent backdrafting. Follow the heating equipment manufacturer’s guideline and safety standards such as those published by the National Fire Protection Association (NFPA), and the American Society for Heating, Refrigeration and Air Conditioning Engineers (ASHRAE), and the local code authorities.
5. When cutting or drilling into wall or ceiling, do not damage electrical wiring and other hidden utilities.
6. Ducted fans must always be vented to the outdoors.
7. Do not use this unit with any solid-state speed control device.
8. To reduce the risk of fire, use only metal ductwork.
9. Use with approved cord-connection kit only.
10.This unit must be grounded.
TO REDUCE THE RISK OF A RANGE TOP GREASE FIRE:
1. Never leave surface units unattended at high settings. Boilovers cause smoking and greasy spillovers that may ignite. Heat oils slowly on low or medium settings.
2. Always turn hood ON when cooking at high heat or when cooking flaming foods.
3. Clean ventilating fans frequently. Grease should not be allowed to accumulate on fan or filter.
4. Use proper pan size. Always use cookware appropriate for the size of the surface element.
TO REDUCE THE RISK OF INJURY TO PERSONS IN THE EVENT OF A RANGE TOP GREASE FIRE, OBSERVE THE FOLLOWING:*
1. SMOTHER FLAMES with a close-fitting lid, cookie sheet, or metal tray, then turn off the burner. BE CAREFUL TO PREVENT BURNS. If the flames do not go out immediately, EVACUATE AND CALL THE FIRE DEPARTMENT.
2. NEVER PICK UP A FLAMING PAN - You may be burned.
3. DO NOT USE WATER, including wet dishcloths or towels - a violent steam explosion will result.
4. Use an extinguisher ONLY if:
A. You know you have a Class ABC extinguisher and you already
know how to operate it.
B. The fire is small and contained in the area where it started. C. The fire department is being called. D. You can fight the fire with your back to an exit. *Based on “Kitchen Firesafety Tips” published by NFPA.
!
CAUTION
1. For indoor use only.
2. For general ventilating use only. Do not use to exhaust hazardous or explosive materials and vapors.
3. To avoid motor bearing damage and noisy and/or unbalanced impellers, keep drywall spray, construction dust, etc. off power unit.
4. For best capture of cooking impurities, your range hood should be mounted 20-25” above the cooking surface.
5. Please read specification label on product for further information and requirements.
IMPORTANT: OBSERVE ALL GOVERNING CODES AND ORDINANCES
Your range hood has been designed to filter out smoke, odors, and grease which rise from the cooking surface. Before you begin the installation be sure that all parts and accessories are removed from carton. For best results and ease in the installation of this range hood, read the instructions sheet to become familiar with the step-by-step installation.
TOOLS AND MATERIALS REQUIRED
Drill, electric or ratchet drive 1/8" drill bit for drilling pilot holes
7/64" drill bit to drill holes for EZ1 brackets mounting screws 1-1/4" wood bit for drilling electrical wiring access hole One common head screwdriver for securing hood mounting screws
to the cabinet and hood sheet metal parts
Pliers for opening knockouts Pencil, rule and level for marking cabinet locations Saber saw or keyhole saw for cutting the wall or cabinet openings Metal snips, duct tape, duct (with elbows and transition, if
necessary), roof cement or caulk, and roof or wall cap, as required
Electrical wiring and supplies of type to comply with local codes
The following materials are required only for installation on recessed bottom kitchen cabinets:
Two 1" x 2" x 12" (approximate length) wood strips (purchase
locally)
Four 1-1/4" long flat head wood screws (purchase locally)
INSTALLER:
LEAVE THIS MANUAL WITH THE HOMEOWNER.
HOMEOWNER:
USE AND CARE INSTRUCTIONS ON PAGE 5.
Register this product at
www.broan.com/register.
To order Service Parts: go to www.broan.com
PREPARING THE HOOD
1. Unpack hood and check contents. You should receive: 1 – Filter with built-in light lens 1 – 3-1/4" x 10" damper/duct connector 1 – Installation parts bag, located inside junction box
LIGHT LENS
ALUMINUM OR COMBINATION FILTER
JUNCTION BOX
2. Remove junction box cover, EZ1 brackets and parts bag from inside junction box.
3. Remove top or rear electrical knockout. Install an appropriate strain relief.
4. Select one of the three types of venting available:
Non-Vented — Remove vent
cover from hood front. Replace the aluminum filter with a non­ducted filter (BP57 or R610050
- purchase separately). Go to "Preparing the Installation Location".
Rectangular Vented — 3-1/4" x 10" vertical or horizontal. Remove
knockout damper/duct connector over opening. Go to "Planning Ductwork
Installation".
for vertical or knockout for horizontal venting. Install
VENT COVER
ROOF CAP
BP87Q DAMPER (NOT INCLUDED) LOCATED AT LEAST 6" FROM HOOD IN VERTICAL SECTION OF DUCT
minimum number of elbows. There are several choices.
ROOF CAP
DAMPER (INCLUDED)
REMOVE THE HOOD DAMPER FLAP IF IT INTERFERES WITH THE WALL CAP DAMPER
Ducting directly through the wall (for range hoods mounted on an
exterior wall). Shown are two ways to duct through an outside wall. If a wall cap is used directly off the back of the hood, special care must be taken to make sure that the damper in the damper/duct connector on the hood and damper in the wall cap do not interfere with each other when the hood is operating. This could result in either inadequate air delivery or back drafts. If this condition does exist, remove the hood damper flap. Sometimes when using a wall cap, it is easier to duct vertically and then use an elbow.
Ducting straight up through roof using 3-1/4" x 10" or 7" round duct.
For single story installations.
Ducting between ceiling joists for multi-story installations or through
soffits above cabinets where soffit connects to outside walls.
Round Vented — 7" vertical. Remove knockouts and exposing
duct collar. Go to "Planning Ductwork Installation".
PLANNING DUCTWORK INSTALLATION
This section is for vented hoods only. For non-vented hoods, skip this section and go to "Preparing the Installation Location".
Begin planning ductwork by deciding where duct will run between hood and outside. For best performance, use shortest possible duct run and a
INSTALLING THE DUCTWORK
THESE INSTRUCTIONS ARE FOR VENTED HOODS ONLY. FOR NON­VENTED HOODS, SKIP THIS SECTION AND GO TO "INSTALLING THE RANGE HOOD".
START AT THE EXTERIOR AND RUN DUCTWORK BACK TO THE RANGE HOOD.
FOR BEST PERFORMANCE OF YOUR RANGE HOOD, USE THE SHORTEST POSSIBLE DUCT RUN AND A MINIMUM NUMBER OF ELBOWS.
NEVER VENT A RANGE HOOD INTO AN ATTIC SPACE BECAUSE A BUILDUP OF GREASE WILL BECOME A FIRE HAZARD.
USE ONLY METAL DUCTWORK (DO NOT USE PLASTIC DUCT). ASSEMBLE SECURELY SO THAT IN CASE OF A GREASE FIRE ON THE RANGE, THE FIRE WILL BE CONTAINED INSIDE METAL DUCTWORK.
IT IS A GOOD PRACTICE TO TAPE ALL DUCT CONNECTIONS, MAKING THEM BOTH SECURE AND AIR TIGHT.
1. Follow appropriate directions below for type of ductwork you are installing.
Wall Cap Discharge: Use saber saw or keyhole saw to cut hole slightly larger than duct size used so that duct will line up easily with damper/duct connector on hood. Install casing strips if cap will be installed on siding. Attach required amount of duct to wall cap and run duct back to hood. Fasten cap to wall and caulk well. Make sure that enough duct runs into the room so that the duct will overlap the damper/duct connector when the hood is installed.
2
Roof Cap Discharge: Cut a hole in roof slightly larger than duct size being used. Trim shingles around hole so that they will fit snugly around hood of cap when cap is installed. Assemble the ductwork and tape all joints. Run ductwork down to hood location. Make sure that enough duct runs into the room so that the duct will overlap damper/duct connector when hood is put into place. Leave 3/4" of duct projecting above roof surface on high side.
Trim duct parallel to roof pitch and seal all around duct with roof cement. Carefully trim shingles and slide back of roof sheet under shingles. Nail
roof sheet to roof under shingles at top two corners and two sides. Nail sheet directly to roof in four places at bottom.
Using roof cement, seal all nail heads and shingles which were cut or lifted. Do not seal bottom edge of roof sheet.
PREPARING THE INSTALLATION LOCATION
NOTE: MOUNT HOOD SO THAT BOTTOM OF HOOD IS 20" TO 25" ABOVE COOKING SURFACE. TOP FRONT OF HOOD SHOULD BE FLUSH WITH FRONT OF CABINET FRAME.
IF DISTANCE BETWEEN WALL AND FRONT OF CABINET FRAME IS MORE THAN 12", THERE WILL BE A SPACE BETWEEN BACK OF HOOD AND WALL. THIS IS NORMAL.
OMIT STEP 1 IF HOOD WILL BE INSTALLED UNDER CABINETS WITH FLUSH BOTTOM OR INSTALLED USING THE EZ1 BRACKETS.
WARNING: WHEN CUTTING OR DRILLING INTO WALL OR CABINET, BE CAREFUL NOT TO CUT EXISTING ELECTRICAL WIRING.
3. Drill 1-1/4" electrical wiring opening in wall or cabinet bottom.
4. Drill four pilot holes in corners of marked duct opening and cut opening with saber or keyhole saw (vented hoods only).
INSTALLING THE RANGE HOOD
This manual covers 2 kinds of installation: the standard (without EZ1 brackets) and the EZ1 one-person installation system. For the standard installation, go to page 4.
EZ-1 ONE-PERSON INSTALLATION SYSTEM
If the cabinet is wider than the range hood width, please use the standard installation method.
Using pliers, break EZ1 brackets apart. Use the appropriate brackets according to the kitchen cabinet type. Refer to the marking on the brackets to determine the correct installation side and orientation.
FRAMED CABINET
XY
FILLER STRIP
1. For cabinets with recessed bottoms only, if not using EZ1 brackets: Install wood filler strips on each side of recessed area under cabinet. Use two 1" x 2" strips cut to length (use thicker strips if necessary). Fasten strips with wood screws about 3" in from each end.
2. Measure and mark the following:
a.) Electrical wiring opening in wall or cabinet. b.) Duct opening in wall or cabinet (vented hoods only).
CABINET CUTOUTS
3-1/4" x 10"
RECTANGULAR
VENTING
4"
5¼"
5¼"
1½"
CABINET CUTOUTS
7" ROUND
VENTING
7/64”
Z
Mate the corresponding bracket to the cabinet side frame, while
placing rear end of bracket against the wall. Use a pencil to mark 3 holes (there are 6 holes but only 3 are necessary).
Remove the bracket. Using a 7/64” drill bit, drill 3 holes where marked.Assemble the bracket to the side frame using a Phillips screwdriver
and 3 provided round head no. 8 x 5/8” wood screws. Repeat for the other side frame.
5"
3
FRAMELESS CABINET
For framed cabinet, secure the hood to the EZ1 brackets using
4 no. 8-18 x 1/2” metal screws (included). Insert 2 screws per side, in the slots. For frameless cabinet, secure the hood to the cabinet using 4 no. 8 x 5/8” round head wood screws (included). Insert 2 screws per side, in the slots.
X
Y
3 X
Z
[ \
7/64”
Align the corresponding bracket to the cabinet side, while placing
rear end of bracket against the wall. Draw a line on the outer edge of the bracket (as shown).
Slide the bracket towards the center of cabinet and align the outside
edge of the bracket with the marked line, keeping the rear end edge leaning on the wall.
Use a pencil to mark 3 holes.Remove the bracket. Using a 7/64” drill bit, drill 3 holes where marked.Assemble the bracket to the cabinet bottom using a Phillips
screwdriver and 3 provided countersunk wood screws. Repeat for the other cabinet side.
The following procedure applies to both framed or frameless cabinet installations.
HORIZONTAL EXHAUST INSTALLATION ONLY
1. Pull house power cable out.
2. Temporarily hang the hood on the brackets using its 2 recessed
REAR HOLES (A and B). While holding the hood, run the house power cable into the hood through the strain relief previously installed.
3. Unhook the rear holes from the brackets and hang the hood using
its 2 recessed FRONT HOLES. While holding the hood, attach the power cable to the hood using the strain relief.
FRAMED CABINET
METAL SCREWS
FRAMELESS CABINET
WOOD SCREWS
STANDARD INSTALLATION
1. Hold hood up against cabinet bottom and trace keyhole slots onto cabinet bottom or filler strips.
KEYHOLE SLOT OUTLINE
FILLER
STRIPS
2. Screw the four supplied screws for mounting the hood into the exact center of the narrow end of the keyhole slots marked underneath the cabinet. Allow 3/8" of the screws to project, so the hood can be fitted into place.
3. Run electric wiring through hole drilled in wall or cabinet. Split wiring for 6" and run the house power cable into the hood through the strain relief previously installed. Attach power cable to the hood.
4. Position hood so that:
a.) Large part of keyhole slots fit over hood mounting screws. b.) Damper/duct connector slides into ductwork (3-1/4" x 10" vented
hoods only)
5. Adjust hood so that hood front is flush with cabinet frame.
6. Tighten hood mounting screws firmly.
A
B
VERTICAL EXHAUST INSTALLATION ONLY
1. Pull house power cable out.
2. Hang the hood on the brackets using the 2 recessed FRONT
HOLES. While holding the hood, run the house power cable into the hood through the strain relief previously installed. Attach power cable to the hood.
CONNECT THE WIRING
WARNING: TURN OFF THE PROPER CIRCUIT AT THE SERVICE ENTRANCE BEFORE WIRING THIS RANGE HOOD. ALL ELECTRICAL CONNECTIONS MUST BE MADE IN ACCORDANCE WITH LOCAL CODES, ORDINANCES, OR NATIONAL ELECTRICAL CODE. IF YOU ARE UNFAMILIAR WITH METHODS OF INSTALLING ELECTRICAL WIRING, SECURE THE SERVICES OF A QUALIFIED ELECTRICIAN.
1. Make electrical connection using wire nuts to connect WHITE wire
to WHITE, BLACK wire to BLACK, and GREEN or bare wire to GREEN ground screw provided.
2. Replace wiring box cover and screw, taking care not to pinch wires.
4