SPECIFICATION SHEET
Quality and double-duty at each installation location.
FEATURES
GRILLE:
Matte white polymeric - blends well with any decor
• Built-in light-diffusing lens accepts 13W fluorescent lamp**
• (Model 679FL) or 22W fluorescent lamp*** (Model 680FL)
or up to 100W incandescent lamp (Models 678, 679 &
680). Bulb not included.
BLOWER:
Plug-in, permanently lubricated motor
• Polymeric blower wheel
HOUSING:
Rugged, 26-gage galvanized steel construction
• Sturdy key-holed mounting brackets for quick, accurate
• installation
Tapered, polymeric duct fitting with built-in backdraft
• damper for easy, positive duct connection and no metallic
clatter
Model 2677H & 3677H: Rough-in housings for 2678F, 2679F, 2680F, FL2679F and FL2680F finish assemblies (packed 4 per carton). 3677H housings include slide chan­nels and mounting brackets.
NOTE: For installation in ceilings up to a 12/12 pitch.
U.L. Listed for use in insulated ceilings (Type I.C.) U.L. Listed for use over bathtubs and showers when con­nected to a GFCI protected branch circuit Use supply wiring rated for at least 90° C
SPECIFICATIONS
MODEL VOLTS AMPS* SONES CFM DUCT
678 120 1.6 2.5 50 4" Round
679 120 2.0 3.5 70 4" Round
679FL 120 1.3 3.5 70 4" Round
680 120 2.2 4.0 100 4" Round
680FL 120 1.7 4.0 100 4" Round
*Total Connected Load
Broan-NuTone LLC, 926 West State Street, Hartford, WI 53027 (1-800-637-1453)
TYPICAL SPECIFICATION
Fan/Light unit shall be Broan Model 678 (679) (679FL) (680) (680FL).
Unit shall have galvanized steel housing with dual integral mounting brackets. It shall be ducted to a roof or wall cap.
Blower assembly shall be removable and have a perma­nently lubricated motor.
Air delivery shall be no less than and sound level no greater than valves listed in the "Specifications" chart on this sheet. Air and sound ratings shall be certified by HVI.
Lamp shall be 100W maximum incandescent (Models 678, 679 & 680) or 13W fluorescent** (Model 679FL) or 22W fluorescent*** (Model 680FL).
Unit shall be U.L. Listed for use over bathtubs and showers when connected to a GFCI protected branch circuit.
Unit shall be U.L. Listed for use in insulated ceilings (Type I.C.).
**Use only one of the following
13W fluorescent lamps: SYLVANIA CF13DD/827
G.E. F13DBX23T4/SPX27 PHILIPS PL-C 13W/27/USA OSRAM CF13DD/827 BROAN 97010729 NEMA Type CFQ13W/GX23
***Use only one of the following
22W fluorescent lamps: SYLVANIA FDL-22
PHILIPS PL-C 15MM/22W PANASONIC FDL22 BROAN 97015191 NEMA Type CFQ20W/GX32d
HVI-2100 CERTIFIED RATINGS comply with new testing technologies and procedures prescribed by the Home Ventilating Institute, for off-the­shelf products, as they are available to consumers. Product performance is rated at 0.1 in.
conducted in AMCA’s state-of-the-art test laboratory. Sones are a measure of humanly-perceived loudness, based on laboratory measurements.
static pressure, based on tests
REFERENCE QTY. REMARKS Project
Location
Architect
Engineer
Contractor
Submitted by Date
50G 99042917D