INSTALLATION AND MOUNTING INSTRUCTIONS
WARNING
Read and understand all instructions carefully before attempting to install, operate or service the Radiant Heater.
Failure to comply with instructions could result in personal injury and/or property damage. Retain instructions for
future reference.
CAUTION: Disconnect appliance from electrical supply before attempting to service or install quartz heater. Heater
must be wired by a qualified electrical installer. Check heater rating plate, element and electrical supply for correct
voltage before installation.
R
US
PLEASE NOTE: Every precaution is taken in packing, however, rough handling will cause breakage, therefore examine
tubes upon delivery and avoid later arbitration as responsibility for breakage. Any claims for damage or loss in transit
must be filed with the carrier. The heater/element has a (1) one year limited warranty from date of purchase.
CLEARANCE TO COMBUSTIBLES
JUNCTION
BOX
TOP TOP
TOP TOP
SIDE SIDE
BOTTOM
TOP - 12 INCHES (30 cm)
SIDES - 18 INCHES (46 cm)
BOTTOM - 24 INCHES (61 cm)
Clearances are measured from the radiant surface and/or heater bottom to the nearest combustible surface. It is
essential that the position and angle of the installation avoids any possibility of curtains, draperies or other inflammable materials coming in contact with heater.
SIDE SIDE
BOTTOM
Space Heating: Mount bottom of heater 8 feet above grade or floor.
NOTE: Brooders are exempt from above grade or floor requirements, all clearances to combustibles must be maintained.
1
MOUNTING
Holes in each end of the heater are used for either chain or bracket mounting. When chain mounting, the off-center
holes may be used to adjust the mounting angle by 20°. Optional brackets are available for wall or ceiling surface
mounting.
Safety Leg
(Brooder Models)
20
20
Chain Mounting
Ceiling or Wall
Surface Mount
3 Positions
Chain Mounting
NOTE: Brooder heaters are equipped with safety legs and must be removed from shipping position and reconnected
so they project below the bottom of the heater.
IMPORTANT: “Quartz-Ray” heaters must be installed so that the length of the quartz tube runs horizontally (see diagram below). Off horizontal installations can cause the element to sag and short out. DO NOT install in a vertical
position.
180° Range
of Adjustment
Bracket Mounting
Install Level
Like This
or Angle Like This
Keeping Quartz Tube
Horizontal
DO NOT Install
So That Quartz Tube is
Off Hortizontal Like This
or This
QUARTZ TUBE INSTALLATION
Tubes are shipped separately and must be installed after installation of heating units. The following steps will facilitate
installation:
1. DO NOT remove element from cardboard tubing by pulling on ceramic end cap.
2. DO NOT remove protective plastic from tube until installed. Tube covering is necessary to avoid finger marks.
3. Upon removal of the end reflectors and guard, the tube clamps and wiring terminals are exposed.
4. Press tube into position and attach wire terminals by removing nut and washer, slip on wire terminal, washer and nut,
then tighten nut by holding ceramic end cap firmly.
5. DO NOT attempt to tighten nut unduly firm.
6. Remove plastic covering from tube - replace guard and end reflectors.
END REFLECTORS
QUARTZ TUBE
TUBE CLAMP
GUARD
CLEANING
Disconnect heater from electrical supply and allow to cool before cleaning.
Clean quartz tube with soft cloth and methyl hydrate.
Periodic cleaning of reflector with a soft duster will ensure an efficient comfortable heat.
2
CLAMP IS ON QUARTZ
TUBE & NOT THE
CERAMIC END CAP