Bowers Group Sylvac Z Cal Height Gauges User Manual

4 (2)
Z_CAL 150
300
Sylvac SA
Ch. du Closalet 16
CH - 1023 CRISSIER
MODE D’EMPLOI
INSTRUCTIONS FOR USE
GEBRAUCHSANLEITUNG
1. DESCRIPTION OF THE INSTRUMENT
1 PRINT key (when measuring)
2 ON / OFF key
3 PRESET key – setting display to zero
4 PROBE CONSTANT key
5 RESOLUTION key
6 NORMAL or DIAMETER / CENTERLINE mode ( ) key
7 Green light = normal measurement
8 Orange light = measuring diameters
9 Yellow light = measuring centerlines
10 Probe
11 Opening for changing the probe holder
12 Nose (yellow section)
13 UP key, with gradual action
14 DOWN key, with gradual action
15 Connector for AC adapter or data transmission foot pedal
16 Green light : indicates the trickle charge with charger connected
17 Red light : indicates fast charging
18 RS232 connector
19 Cover screw
20 Counterweight locking screw for shipping
21 Top cover
2. DISPLAY FUNCTIONS
22 Display in metric mode
23 Display in inch mode
24 Measuring direction display
25 Displayed value = shaft or bore centerline
26 Displayed value = shaft or bore diameter
27 PRESET mode indicator
28 - Displays the value of the probe constant
- Indicates that the keyboard is locked
29 Minimum mode active
30 Maximum mode active
29, 30TIR mode active = Maximum - Minimum
31 Reference 2 active
32 Battery life warning display - connect charger
33 Cursor for introducing the PRESET
CONTENTS Page
1. Description of the instrument 15
2. Display functions 15
3. Introduction 17
4. Getting started 17
5. How to start up 18
5.1 Measuring heights 18
5.2 Measuring reverse surfaces - Measuring the probe constant 18
5.3 Measuring diameters and centerlines 19
6. Main functions 20
7. Secondary functions 21
8. AC adapter, external contact 22
9. RS232 connector 22
10. Change of the probe holder 24
11. Adjusting the measuring force 24
12. Replacing the batteries 24
13. Technical specifications 25
14. Standard package 25
15. Accessories 26
3. INTRODUCTION
The Z_CAL height gauge is designed to work on a flat reference surface, such as granite or
scraped cast iron plate... A number of technological innovations make this instrument very
suitable for fast, accurate and reliable measurements. It offers the following main advantages :
Very low measuring force (30 grams) for delicate parts and excellent repeatability.
Fully motorized probe. Its displacement speed is proportional to the finger pressure. The
probe automatically tracks profiles and maintains a constant measuring force : measuring
diameters is, therefore, quick and precise.
Reduced weight, for easy handling.
Very easy to operate, so that it can be used both in the workshop and laboratory.
4. GETTING STARTED
Unscrew screw (19) and remove cover (21).
Unscrew and remove the M4 x 30 mm screw (20) which secures the counterweight during
shipping. Remove the locking insert and place the screw it in the provided thread bore.
Note : the locking of the counter weight is done with the probe down. Remove the probe
holder for transport.
Connect the AC adapter (15) : - red light = fast charging 4 hours
- green light = trickle charge
Note : charging continuously will not affect the batteries. If the batteries are completely down,
the Z_CAL may start searching for its references, moving first to the upper stop (Ref 1) and
then to the bottom stop (Ref 0).
Press ON (2) to start up the Z_CAL.
Press up (13) to the upper stop. Introduce the probe holder in the provided location, when
pushing up.
Press UP (13) or DOWN (14). The speed is proportional to the pressure applied to these
sensitive keys.
Important : The insert as well as the screw must be replaced for subsequent shipping of
the instrument,
for inspection or overhaul, as part of after-sales service.