Bosch ITS-D6686-UL Specsheet

Intrusion Alarm Systems | Conettix ITS‑D6686 Ethernet Network Adapters
Conettix ITS‑D6686 Ethernet Network Adapters
www.boschsecurity.com
u 10Base-T/100Base-T network connection for IP
account monitoring and central station automation
The Conettix ITS‑D6686 Ethernet Network Adapters (ITS‑D6686‑INTL and ITS‑D6686‑UL) are used to connect the Conettix D6600 Communications Receiver/Gateway to IPv6 and IPv4 networks (LAN/WAN/Internet). The adapter allows the D6600 to process messages to and from most networks using User Datagram Protocol/Internet Protocol (UDP/IP). Conettix ITS‑D6686 Ethernet Network Adapters are compatible with both IPv6 and IPv4 networks. A minimum of one adapter is required for each D6600. The two serial ports allow for a variety of installation options including Network Failover Solution.
Functions
Network Failover Solution
A Conettix System with two D6600 receivers and two ITS‑D6686 adapters can be used to allow for a redundant backup in the event of first system failure. Each adapter has two serial ports that allow it to be connected to a primary and backup receiver at the same time. In this configuration using the D6200 software, when the primary receiver is updated the backup receiver will also be updated. Each adapter also supports an alternate MAC Address that can be used to switch between adapters on primary and
u Two DB9 serial interfaces provide connection to
D6600/D6672
u Light emitting diodes (LEDs) provide status and
activity
u Supports 128-bit to 256-bit AES (Rijndael)
encryption
backup systems without any network problems. Refer to the Conettix D6600 Systems Guide - Network Communications for details.
Certifications and approvals
Notice
Install the Conettix D6600 Communications Receiver/Gateway in accordance with NFPA 70, NFPA 72 and the local Authority Having Jurisdiction (AHJ). The Conettix ITS‑D6686‑UL Ethernet Network Adapter is suitable for Central Station Protective Signaling when it is installed and used in compliance with NFPA 72 and ANSI/ NFPA 70. Installation limits for Digital Alarm Communicator Receivers (DACR) are under the jurisdiction of the user’s local authority.
Notice
For UL Listed Fire Installations, equipment between Ethernet Interface Modules and the ITS‑D6686‑UL is required to be UL Listed Information Technology Equipment.
2 | Conettix ITS‑D6686 Ethernet Network Adapters
Region Certification
USA CSFM 7300-1615:0179 FIRE ALARM CON-
TROL UNIT ACCESSORIES/MISC. DEVI­CES
Installation/configuration notes
Compatibility Information
Receivers: Conettix D6600 Communications Receiver/
Gateway
Location and Enclosures
The ITS‑D6686 adapters must be installed in the same room as the D6600 receiver and be within 15 m (50 ft) of the D6600. For UL installations, the ITS‑D6686‑UL must be installed in the same rack as the D6600 and be within 6 m (20 ft) of the D6600.
Parts included
ITS‑D6686‑INTL
Quantity Component
1 ITS‑D6686‑INTL Ethernet Network Adapter
1 Plug‑in power supply with adapters
1 DB9 F/F null modem serial cables (1.83 m [6 ft])
1 Literature – Installation Guide
ITS‑D6686‑UL
Environmental
Temperature (operating): 0°C to +50°C (+32°F to +122°F)
Temperature (storage): -40°C to +85°C (-40°F to +185°F)
Mechanical
Unit Dimensions (not including mounting tabs):
Weight: 0.26 kg (0.6 lb)
Protocols Supported: ARP, UDP/IP, TCP/IP, Telnet, ICMP,
Serial Connectors: Two DB9M DTE serial ports
Network Connectors: One RJ45 10BASE-T or 100BASE-TX
Ethernet Cable: Category 5 or better unshielded twisted
RS‑232 Cable: Installed in the same room as the D6600;
Management: HTTP (internal web server)
System Software: Flash ROM standard. Downloads from a
9.5 cm x 7.3 cm x 2.3 cm (3.75 in. x 2.9 in. x 0.9 in.)
SNMP, DHCP, TFTP, HTTP, and BOOTP
Ethernet port
pair installed in the same enclosure/rack as the D6600. For UL installations a maximum length of 6 m (20 ft) is allowed.
maximum length 15 m (50 ft). For UL installations, installed in the same rack as the D6600; within 6 m (20 ft).
Telnet login DeviceInstaller software
TCP/IP host (TFTP) or over serial port.
Quantity Component
1 ITS‑D6686‑UL Ethernet Network Adapter
1 Plug‑in power supply
2 DB9 F/F null modem serial cables (1.83 m [6 ft])
1 Literature – Installation Guide
Technical specifications
Electrical
Power Input
INTL model: AC nominal operating range: 100 VAC to
240 VAC, 50 Hz/60 Hz, 400 mA maximum
UL model: AC nominal operating range: 120 VAC, 60 Hz,
150 mA maximum
Notice
An uninterrupted power supply (UPS) is required for use with the ITS‑D6686‑UL when used for UL Fire (UL1481) Protective Signaling Systems. A 24 hr. minimum UPS standby power supply is required for UL Certification.
Diagnostic LEDs: On top of unit:
Power / Diagnostic (Blue) RX Serial 1 Activity LED (Green) TX Serial 1 Activity LED (Yellow) RX Serial 2 Activity LED (Green) TX Serial 2 Activity LED (Yellow) On the RJ45 Ethernet connector: Ethernet Link LED on the left (Bi‑color, 10 Mbps = Yellow, 100 Mbps = Green) Ethernet Activities LED on the right (Bi‑color, Half Duplex = Yellow, Full Duplex = Green)
Compatibility: Ethernet: v2.0/IEEE 802.3
Conettix D6600 Communications Receiver/Gateway
Trademarks
All hardware and software product names used in this document are likely to be registered trademarks and must be treated accordingly.
Ordering information
Conettix ITS-D6686-INTL Ethernet Network Adapter
Order number ITS-D6686-INTL
Conettix ITS-D6686-UL Ethernet Network Adapter
Order number ITS-D6686-UL