Bosch ITS-D6686-INTL User Manual

Page 1
EN
Conettix ITS-D6686-INTL
Installation Guide
Ethernet Network Adapter
Page 2
Conettix ITS-D6686-INTL |
Installation Guide | Contents
2
Bosch Security Systems, Inc. | 11/12 | F01U274797-02
Contents
1.0 Introduction ...................................................... 3
1.1 Network Interface................................................. 3
1.2 Serial Interface..................................................... 3
1.3 LEDs .................................................................... 3
2.0 Installation ........................................................ 4
2.1 Mounting the D6686 ............................................ 4
2.2 Connecting the D6686 ......................................... 4
3.0 Configuring and Programming the D6686 5
3.1 Factory Default IP Address .................................. 5
3.2 Identifying the MAC Hardware Address .............. 5
3.3 Obtaining an IP Address ...................................... 5
3.4 Using the D6200 to configure the D6686 ............ 5
3.5 Programming Overview for the D6600 ................ 8
4.0 Specifications ................................................... 9
Page 3
Conettix ITS-D6686-INTL |
.
Bosch Security Systems, Inc. | 11/12 | F01U274797-02
3
Figure 1: Power/Ethernet
Figure 2: D6686 Network Interface
Table 1: D6686 LEDs
LED
Description
Steady On: Blinking 2x: Blinking 2x:
Off: Blinking:
Off: Blinking:
Off: Blinking:
Off: Blinking:
Off: Solid Yellow:
Solid Green:
Off: Solid Yellow:
Solid Green:
Trademarks
All hardware and software product names used in this document are likely to be registered trademarks and must be treated accordingly.
Copyright
This document is the intellectual property of Bosch Security Systems, Inc. and is protected by copyright. All rights reserved.

1.0 Introduction

The Conettix D6686 Ethernet Network Adapter is a two-channel network adapter that supports IP Addresses for both IPv4 and IPv6 environments. Networked installations can have one if it is only used with one D6600 receiver or two configured channels when used with a backup D6600 receiver configuration.
Follow these instructions to avoid the possibility of harm to the operator, or damage to the equipment.

1.1 Network Interface

Installation Guide | 1.0 Introduction

1.2 Serial Interface

1- Power/Diagnostic LEDs 2- Serial Port 2 (DTE) – optional (use
supplied cable if required)
3- Serial Port 1 (DTE) – use supplied null
cable

1.3 LEDs

1- Ethernet Link LED 2- RJ45 Ethernet Jack 3- Ethernet Activity LED 4- Reset Pin
5- Power Plug
Power/Diagnostic (Blue)
RX Serial 1 Activity (Green)
TX Serial 1 Activity (Yellow)
RX Serial 2 Activity (Green)
TX Serial 2 Activity (Yellow)
Ethernet Link (Bi-color LED on left)
Ethernet Activity (Bi-color LED on right)
Power OK
No DHCP response Setup Menu active
No data activity
Data received by
D6686 on Channel 1
No data activity
Data transmitted from
D6686 on Channel 1
No data activity
Data received by
D6686 on Channel 2
No data activity
Data transmitted from
D6686 on Channel 2
No Ethernet link established
10 Mbps Ethernet
link established
100 Mbps Ethernet
link established
No data activity
Half Duplex data
activity
Full Duplex data
activity
Page 4
Conettix ITS-D6686-INTL |
Installation Guide | 2.0 Installation
4
Bosch Security Systems, Inc. | 11/12 | F01U274797-02
Figure 3: D6686 Connections

2.0 Installation

2.1 Mounting the D6686

Mount the D6686 on a rail or other user-supplied spot behind the D6600 that it will be connected to. Refer to Figure 3.

2.2 Connecting the D6686

Connect the D6686 as follows:
Power cable to an available electrical outlet
Ethernet cable to network switch
RS-232 serial cable to Serial 1 port
Refer to the D6600/D6100IPv6 Installation and Operation Guide – Network Communication section, (P/N: 4998122704) for applications
using both serial ports.
Refer to Figure 3.
1– Power cable 2– Ethernet cable 3– RS-232 serial cable (Serial 1 port) 4– Serial 2 port (empty) 5 – Standard 19-in. mounting rack
Page 5
Conettix ITS-D6686-INTL |
.
Bosch Security Systems, Inc. | 11/12 | F01U274797-02
5
Figure 4: MAC Address Location
1
3.0 Configuring and
Programming the D6686

3.1 Factory Default IP Address

By default, the D6686 uses DHCP to obtain an IP Address. The unit requires a static IP Address. Refer to Sections 3.2, 3.3, and 3.4 for more information.
3.2 Identifying the MAC Hardware
Address
1. Verify that the D6686 is properly installed,
connected, and powered. Refer to Section 2.0 Installation on page 4.
2. Locate the D6686’s media access control
(MAC), or hardware, address.
The MAC address is hard-coded into the D6686 during manufacturing, and it cannot be changed. This address is 6 bytes (12 digits) in length and is located on a label on the D6686 in the format of “xx-xx-xx-xx-xx-xx”.
1- MAC address location on D6686 label
3. Record the MAC address and keep it for
reference.

3.3 Obtaining an IP Address

Provide the D6686’s MAC address to the site’s network administrator, who will assign an IP address for the D6686.
An IP Address is an identifier for a computer or device on a transmission control protocol/internet protocol (TCP/IP) network. Networks use the TCP/IP protocol route messages based on the IP address of the destination. The format of an IP address using IPv4 is a 32-bit numeric address written as four numbers or fields separated by periods. Each number can be 0 to 255. The format of an IP address using IPv6 is a 128-bit numeric address written as eight groups of four hexadecimal digits separated by colons.
Installation Guide | 3.0 Configuring and Programming the D6686
For example, 190.200.128.111 could be an IPv4 address and 2001:0db8:85a3:0042:0000:8a2e:0370:7334 could be an IPv6 address. Within an isolated network, you can assign IP addresses at random if each one is unique. However, connecting a private network to the Internet requires using registered IP addresses (called Internet addresses) to avoid duplicates. IPv6 addresses are typically set using DHCP on the network. The D6686 supports IPv4 and/or IPv6 addressing schemes or both at the same time.
3.4 Using the D6200 to configure the
D6686
Bosch Security Systems, Inc. recommends that you read this entire section before proceeding.
In order to access the configuration program, ensure that the D6686 and the PC used to configure it are directly connected using an Ethernet cable.
Be sure that the PC being used to configure the device is configured to use DHCP to obtain an IP Address. When it is connected directly to the D6686 it will obtain
The D6200 Software is the recommended way to program the network devices. Review Section 3.5 Programming Overview for the D6600 on page 8 and the Network Utilities section in the D6200
Programming Software Operation and Installation Guide (P/N: 4998154991).
1. When you have the IP address and the
2. With the PC already booted and running,
an Auto-IP address.
network administrator confirms that it is ready, connect the Ethernet port of the D6686 directly to the PC Ethernet port using an Ethernet cable.
apply power to the D6686 and wait approximately 1 minute for the PC and D6686 to acquire an Auto-IP Address (169.254.xxx.xxx).
Page 6
Conettix ITS-D6686-INTL |
Installation Guide | 3.0 Configuring and Programming the D6686
6
Bosch Security Systems, Inc. | 11/12 | F01U274797-02
3. Open the D6200 software and select
Network – Network Utilities - Network Device Setup as shown below
4. Select List All Conettix IP Devices tab
and click the
Start button. The program
will scan the network for the device.
5. The D6686 will be shown in the list with
the IP address. Record the IP address that is listed is shown.
6. Select XML Configuration tab and click
Setting button. Enter in the Setting
the dialog:
D6686/D6100IPv6 IP: The IP address
recorded in the previous step
FTP User Name: admin
FTP Password: PASS
Click OK
7. Click the Open XML button, select
D6686.xml, and click Open.
8. Make changes to the parameters that are
required for your particular installation scenario by selecting the specific item, enter the required changes, and click Change. The values that are changed will be displayed in red as shown below. All of the programmable configuration parameters are listed on the next page with the valid values.
Page 7
Conettix ITS-D6686-INTL |
.
Bosch Security Systems, Inc. | 11/12 | F01U274797-02
7
Installation Guide | 3.0 Configuring and Programming the D6686
Page 8
Conettix ITS-D6686-INTL |
Installation Guide | 3.0 Configuring and Programming the D6686
8
Bosch Security Systems, Inc. | 11/12 | F01U274797-02
9. Click on the Save XML As button to save
the changes made and enter a name for these configuration settings.
10. Click on the Send XML button to send
these changes to the D6686. The device will save the changes and reboot with the new configuration.
11. Disconnect the Ethernet cable connecting
the PC and the D66868 and connect the D6686 to the network switch or router as
The number and type of receiving lines in use
Sending the files back to the D6600
(CPU/Host/Network, Account Database, or Line Card)
Upgrading the Software installed in the
D6600 (CPU, System, or PSTN line cards)
Refer to the D6200 Software Operation and Installation Guide (P/N: 4998154991) for information and procedures on how to accomplish these tasks.
required.
The D6686 is a Lantronix EDS-2100 with custom firmware installed and UL Listed for use on the D6600. If standard Lantronix firmware is installed on a D6686, the device will no longer function on a D6600.
If encryption is enabled on the D6686, you must enable it on all field devices (B420, DX4020-G, B5512, etc) with the same key. Encryption must also be enabled in the D6600 Receiver. Refer to the D6600 Program Entry Guide (P/N:
4998122702).
The network interface module (DX4020, C900V2, C900TTL-E, or D9133TTL-E) must have the proper software version to support encryption. For more details, refer to the Device Installer Operation and Installation Guide (P/N:
4998138688).
3.5 Programming Overview for the
D6600
The D6600 Receiver is shipped with factory default program parameters and features already installed. Descriptions of the program items are found in the D6600 Program Entry Guide (P/N:
4998122702). Many of the operational features of the D6600 can be altered through programming options. The programming options you choose depend on:
The type(s) of peripheral reporting device(s)
used in your central station (for example external printer or automation computer)
The supervision characteristics for these
devices
The type of communicators reporting to the
receiver
Page 9
Conettix ITS-D6686-INTL |
.
Bosch Security Systems, Inc. | 11/12 | F01U274797-02
9
Table 2: Specifications
Supported Protocols
Connectors
Serial:
Network:
Cables
Ethernet: Max Length:
RS-232:
Max Length: Data Rates
Serial speed ranging from 300 bps to 115.2 kbps (D6600 supports 38400 bps)
Serial Line Formats
Characters
Stop bits:
Parity:
Modem Controls
Flow Control
Management
System Software
Diagnostic LEDs Compatibility
AC Current Required
Power Input
Environmental
Operating Temperature:
Storage Temperature:
Dimensions (H x W x D):
Unit:
Weight

4.0 Specifications

ARP, UDP/IP, TCP/IP, Telnet, ICMP, SNMP, DHCP, BOOTP, TFTP, and FTP
CAT5 or better unshielded twisted pair
Odd, even, none DTR, DSR Software: XON/XOFF
Hardware: CTS/RTS FTP
SNMP (read only) Serial login Telnet login Flash ROM standard: downloadable from a TCP/IP host (TFTP), FTP, or over serial port
Power 10/100 Mb Link on RJ45, 10/100 Activity on RJ45 RX Serial 1 Activity, TX Serial 1 Activity, RX Serial 2 Activity, TX Serial 2 Activity Ethernet: v2.0/IEEE 802.3 D6600 UPS Standby Current: 0.4 A
Installation Guide | 4.0 Specifications
2 - DB9M DTE serial ports
1 - RJ45 10Base-T/100Base-TX Ethernet port
6 m (20 ft) and installed in same enclosure/rack as
D6600.
6 m (20 ft) and installed in same enclosure/rack as
D6600.
7 or 8 data bits
1 or 2
AC nominal operating range: 100 to 240 VAC, 50/60 Hz, 0.4A max
0° to 50° C (32° to 122° F)
-40° to 85° C (-40° to 185° F)
3.75 in. x 2.9 in. x .9 in. (9.5 cm x 7.3 cm x 2.3 mm)
0.6 lbs. (0.26 kg)