FPA-1000-UL Fire Alarm Control Panel
Quick Guide
Top Benefits of the FPA-1000-UL
e Unbeatable value, offering best price/feature ratio in its class
e Reduced installation time and costs with minimal
plug-in modules
e Convenient internet access with built-in, self-contained web server
and dedicated web pages
e Built-in Digital Alarm Communicator Transmitter (DACT) and
Conettix IP Alarm Over IP reporting as standard – no need to
purchase extra modules or parts to get IP communication
e Consistency in service parts and inventory by using Bosch’s own
option bus feature built-in, which uses the same accessories as
the FPD-7024
e Meets the need for carbon monoxide and other toxic gas detection
in one panel with UL listed gas detection
e Simple installation and programming, thanks to simple design
and engineering
e Easy operation and understanding during emergency events with
smart design keypad featuring larger buttons and symbols
Ease of use and functionality
e Large 4-line by 20-character LCD display
e Six LED status indicators on each panel keypad or remote LCD annunciator, including gas alarm LED
e Menu-driven user interface on panel
e Easy programming from panel keypad
e Browser-based user interface for programming and diagnostics on a networked PC with Microsoft® Windows® XP and Microsoft®
Windows® Vista or Unix/Linux based operating system – no software installation required
e 4 Programmable authority levels secured with a user-definable, four-digit PIN
e 128 software zones for flexible input-output mapping
e Auto Learn feature for easy start-up programming
e Local piezo sounder
e Fire drill test function
e Walk test function
e Alarm verification feature
e Bypass or unbypass points, outputs or zones individually
e 1000 events history buffer
e Event and history printing via network printer
e Three languages built-in (English, Spanish and Portuguese), software configurable, LED and keypad labeling easily exchangeable
Features
e Up to two analog addressable Signaling Line Circuits
(SLC) configurable as: Four Class B Style 4 or Two
Class A Style 6 or 7
e Up to 127 detectors and modules per SLC Loop for a
total of 254 addresses
e Uses standard wire – no shielded or twisted pair required
on SLCs
e Programmable sensitivity levels per device and automatic
day and night sensitivity modes
e Automatic calibration and drift compensation routine
e 120/240 VAC power; total 5.5 A transformer output
e Two integrated Notification Appliance Circuits (NAC)
rated at 2.5 A each, allowing up to 4 Amps of current
(shared among auxiliary power, option bus and NAC)
e Up to four addressable Remote NAC Boosters, providing
auxiliary power and up to 16 synchronized remote
NAC circuits
e Mainboard NAC patterns include Steady, Pulsing,
Temporal Code 3 and Temporal Code 4
e Built-in synchronization protocol for notification devices:
Wheelock™ and System Sensor®
e Three programmable Form C relays on the mainboard
(fire, trouble, supervisory, gas alarm and activation
by zone)
e Option bus for optional boards and expansions including
LCD/LED annunciators, Octal Driver Module, Octal Relay
Module and Remote NAC Booster
e Optional FPE-1000-CITY City Tie Plug-in Module with two
circuits, each programmable to Local Energy or
Reverse Polarity
e Built-in Ethernet interface for Conettix IP reporting and/
or programming and diagnostics
e Built-in dual phone line: public switched telephone
network (PSTN) and IP DACT communicator
e Contact ID, SIA 300 and Modem IIIa2 reporting formats
e Positive Alarm Sequence
e Pre-Signal
Listings and Approvals
e UL Listed 864 9th edition
e FM (pending)
e CSFM
e MEA (pending)
e FCC parts 15, digital devices and part 68 phone connections
FPA-1000-UL Fire Alarm Control Panel
Quick Guide — Accessories
Option Bus Accessories
FMR-1000-RCMD Remote Command Center
Remote operational terminal of the FPA-1000-UL panel, providing
buttons for silence, reset, acknowledge and drill. Features scrolling
keys, key switch with 1358 key and built-in piezo sounder.
FMR-1000-RA Remote Annunciator
Remote LCD annunciator featuring acknowledge key. Includes
scrolling keys and built-in piezo sounder.
D7032 Eight-Zone LED Annunciator Expander
Attaches to a D7030X, D7030X-S2 or D7030X-S8.
Identifies the location of a fire alarm for eight additional zones,
showing 16 LED zones in the D7030X/D7032 combination.
D7048/B Octal Driver Modules
The outputs are fully programmable and can be activated by system
events. These outputs have the same programming options as the
local relays. Each output operates independently of the other seven
to provide complete flexibility.
D7035/B Octal Relay Module
The FPA-1000-UL supports up to two Octal Relay Modules. The
outputs are fully programmable and can be activated by system
events. These outputs have the same programming options as the
local relays. Each output operates independently of the other seven
to provide complete flexibility.
D7030X LED Annunciator
Identifies the location of a fire alarm for up to eight zones allowed
per system.
D7030X -S2 LED Annunciator
Features two zones reserved for supervisory functions. Incorporates power and trouble LEDs plus eight-zone LEDs that can be
individually labeled.
D7030X-S8 LED Annunciator
Features eight zones reserved for supervisory functions. Incorporates power and trouble LEDs plus eight-zone LEDs that can be
individually labeled.
Control Panel Accessories
FPP-RNAC-8A-4C Remote Notification Appliance Circuit Power
Supply
The FPP-RNAC-8A-4C Remote NAC Booster adds four additional
Notification Appliance Circuits: NFPA 72, Class B (Style Y) or Class
A (Style Z) to the fire panel or serves as a power supply for fire
protective signaling systems.
D126 (12v 7ah), D1218 (12v 18ah), D1224 (12v 24ah), D1238
(12 38ah) Secondary Battery
2 x 12 V, 18 Ah maximum within enclosure or 40 Ah
maximum external.
BATB-40 / BATB-80 Battery Box
Provides a single level (two-battery capacity) of battery storage with
an optional shelf that increases the battery capacity to four batteries. BATB-80 includes a mounted shelf that holds up to
four batteries.
FPM-1000-SFMK Semi-flush Mounting Kit
Includes trim ring and mounting accessories.
FPE-1000-SLC Signaling Line Circuit Module
Provides a Signaling Line Circuit for connection of analog DCP devices to the FPA_1000_UL Compact Fire Panel. A second Signaling
Line Circuit can easily be added by plugging in the FPE-1000-SLC
to the mainboard. Nominal 39 V DC (30 to 40 V DC), 200 mA
maximum (per SLC), power-limited, supervised.
FPE-1000-CITY City Tie Plug-in Module
Provides two circuits that can be programmed as Local Energy or
Reverse Polarity module.
Programming Tool
D7050: Analog Device Programmer
Handheld device that programs address settings on EEPROM
programmable analog devices. Includes base for detector head
programming and two-module program adapter for module
programming (for 4-in or single-gang back box). Shows the current
analog value of a connected detector.
Initiating Devices
FAA-325-B6 Analog Detector Base
Compatible with all analog addressable detectors that use the
advanced analog communication protocol, except the ALG-DH. 6 in
(15 cm) diameter.
FAA-325-B4 Analog Detector Base
Compatible with all analog addressable detectors that use the
advanced analog communication protocol, except the ALG-DH. 4 in
(10cm) diameter.
FAP-325 Analog Photoelectric Smoke Detector
Detects optically dense smoke typical of fires involving materials
such as soft furnishings, plastic and foam, which tend to smolder
and produce large, visible smoke particles.
FAH-325 Analog Heat Detector
Detects heat in environments where smoke detectors are unsuitable
because of the presence of system or cooking fumes, such as
a kitchen.
FAI-325 Analog Ionization Smoke Detector
For use in areas where early warning of superheated or flaming
combustibles is expected. Also designed for use where outside
Radio Frequency Interference (RFI) and other electrical interference
are expected.
FAA-325-B6S Analog Sounder Base
Contains an addressable sounder that provides an audible alarm
in the immediate vicinity. Compatible with all analog addressable
detectors that use the advanced analog communication protocol,
except the ALG-DH. Auxiliary powered. The Analog Sounder base’s
address is programmed automatically. (For this device, the address
of the mounted detector plus 127 come up to the sounder
base address.)
FFAD-325 Series Analog Duct Smoke Detector
Provides early detection of smoke and products of combustion
present in air moving through HVAC ducts in commercial, industrial
and residential applications.
Three types available:
e FAD-325-DH Analog Duct Smoke Detector
Replacement Head
e FAD-325 Analog Duct Smoke Detector (with Housing)
e FAD-325-R Analog Duct Smoke Detector with two Relays
(with Housing)
Accessories
e FAA-325-2.5 Testing Tube, 2.5 ft length
e FAA-325-5 Testing Tube, 5 ft length
e FAA-325-10 Testing Tube, 10 ft length
Input/Output Modules
FLM-325-CZM4 Conventional Zone Module
Monitors dry contacts (NO) devices such as two-wire conventional
detectors and pull stations. Transmits the status of one zone
of devices back to the panel (25 maximum per zone; number
depends on type of connected devices). Class A or Class B wiring
is configured with a jumper on the module. Auxiliary powered. The
number of Conventional Zone Modules (CZM) per SLC module is
limited to 64.
FLM-325-2I4 Dual Input Monitor Module
Provides two independent contact monitoring circuits while utilizing
only one address on the SLC. Can be programmed to monitor
normally open or normally closed contact fire alarm and supervisory
devices (NO EOL, NC EOL, NC no EOL). Supervises with Style B
(Class B). Loop powered.
FLM-325-2R4 Dual Relay Module
Allows independent control of two Form C contacts (rated for 1.0
A at 30 VDC or 0.5 A at 125 VDC) for a variety of normally open
(NO) and normally closed (NC) contact applications such as fan
operation, elevator recall, door closure and auxiliary notification.
Loop powered.
FLM-325-ISO Short Circuit Isolator
Isolates a shorted section on a specific polling circuit from the rest
of the system to minimize the loss of devices.
FLM-325-N4 Supervised Output Modules
Provide a supervised pole reversal output used for acoustic and
optical signaling devices or to trigger a Remote NAC Booster.
Require a 24 VDC auxiliary input voltage. The output relay is rated to
supply 2 A at 30 VDC. Provide Steady, Pulsing and Temporal Code
3 output pattern.
FLM-325-I Series Fast Response Contact
Monitor Modules
Designed for use with pull stations, water flow switches and other
applications requiring the monitoring of dry contact alarm initiating
devices. Can be programmed in NO EOL, NC EOL, NC no EOL.
Three types available:
e FLM-325-I4 with 4-in Back Box
e FLM-325-IS with Terminal Screws (future release)
e FLM-325-IW with Pigtail (future release)
FMM-325A/FMM-325A-D Analog Manual Pull Station
Fast response contact monitor module mounted in a corrosionresistant, rugged, die-cast housing for single-gang mounting.
Loop powered.