Bosch FMR-7033 Installation Instructions Manual

FMR-7033
Installation Instructions
EN
Controller
EN | 2 FMR-7033 | Installation Instructions | Contents
Contents
Contents ...........................................................................2
1.0 Introduction ......................................................3
2.0 Description........................................................3
3.0 Device Mounting .............................................3
3.1 Mounting the FMR-7033 to a Surface .............3
3.2 Mounting the FMR-7033 to an Electrical Box3
4.0 Wiring the FMR-7033 ......................................4
5.0 Powering the FMR-7033 .................................4
6.0 Installing the FMR-7033 Instruction Label
and Slide ............................................................5
7.0 Setting the FMR-7033’s Address ...................5
8.0 Programming the FMR-7033 ........................5
9.0 Troubleshooting the FMR-7033 ...................5
10.0 Specifications ....................................................6
11.0 Operating the FMR-7033................................7
Figures
Figure 1: Removing the FMR-7033 Cover...............3
Figure 2: Location of the FMR-7033 Base Mounting
Holes ............................................................4
Figure 3: Wiring the FMR-7033’s Terminal Strip....4
Figure 4: Installing the Instruction Label and Slide.5
Figure 5: FMR-7033 Keypad Addresses ...................5
Figure 6: Keypad Features..........................................7
Tables
Table 1: FMR-7033 Wiring Guidelines ...................4
Table 2: FMR-7033 Troubleshooting Tips ..............6
Table 3: FMR-7033 Specifications............................6
2 Bosch Security Systems, Inc. | 9/08 | F01U010583-01
.
1.0 Introduction
These instructions cover the installation of the Bosch Security Systems, Inc. (Bosch) FMR-7033 Addressable Fire System Controller in a fire system supervised by a Bosch FPD-7024 Fire Alarm Control Panel (FACP).
FMR-7033 | Installation Instructions | 1.0 Introduction
Figure 1: Removing the FMR-7033 Cover
1
(Bottom front view of FMR-7033)
Follow these instructions to avoid personal injury and/or damage to equipment.
Install, test, and maintain these devices according to these instructions, NFPA 72, Local Codes, and the Authority Having Jurisdiction (AHJ). Failure to follow these instructions might result in failure of the device to initiate a proper response. Bosch is not responsible for improperly installed, tested or maintained devices.
2.0 Description
The FMR-7033 Addressable Fire System Controller is a four-wire alphanumeric LCD keypad that combines fire system annunciator and controller functions. It operates identically to the built-in user interface on the FACP. Up to four FMR-7033 controllers might be connected to an FPD-7024.
The FMR-7033 can be surface mounted, mounted to a single or double gang box or to a four-inch square box.
2
1 - Keypad Keys 2 Insert small flat screwdriver in each slot to
remove FMR-7033 cover
3.1 Mounting the FMR-7033 to a Surface
1. Use the base as a template and mark the location of the mounting holes (use any holes).
2. Provide an opening in the mounting surface for the wiring.
3. Partially install the mounting screws.
Do not tighten the mounting screws.
3.2 Mounting the FMR-7033 to an
Electrical Box
Refer to Figure 2 on page 5 to select mounting holes. Do not tighten the mounting screws.
3.0 Device Mounting
The FMR-7033 should be mounted no higher than shoulder height of the shortest person using the system.
Remove the keypad’s cover by inserting a small flat­head screwdriver in each slot at the bottom of the base. Press up and pull the cover off (
Bosch Security Systems, Inc. | 9/08 | F01U010583-01 3
Figure 1).
Loading...
+ 5 hidden pages