DS940/DS940T
Passive Infrared Detector
Installation Instructions
1.0 Description
The DS940 is a high performance Passive Infrared (PIR) Motion Sensor which uses advanced signal processing to provide outstanding
catch performance and unsurpassed false alarm immunity. It is designed to detect movement in the interior of a structure by sensing the
Infrared energy emitted from the human body as it moves across the sensor’s field of view. When motion is detected the unit sends an alarm
signal to the control panel.
2.0 Specifications
• Input Power: 9-15 volts DC
• Current Draw: 17 mA @ 12 VDC (standby and maximum)
• Standby Power: No internal standby battery. For UL Listed Prod-
uct Installations, 4 hours (68 mAh) standby
power must be provided by the control unit or
by a Listed burglary power supply.
• Relay Form “A” Normally Closed (NC) contact set
rated for 125 mA@ 28 volts maximum DC, 18
volts maximum AC for resistive loads.
• Tamper: (DS940T only) Normally Closed (with cover on).
Contacts rated at 28 VDC, 125 mA max. Connect tamper circuit to a 24hr. protection circuit.
3.0 Installation
3.1 Remove the cover using a
small flat-blade screwdriver.
Bottom of Detector
3.2 Press the vertical adjust
tab toward the side of the
case and lift out the board.
• Temperature: -20° to +120°F (-29° to +49°C).
For UL Listed installations, the temperature
range is +32°F to +120°F (0°C to +49°C).
• Humidity: 0 - 85% non-condensing.
• Dimensions: 3 in. x 2.25 in. x 1.5 in. (HxWxD)
(7.6 cm x 5.7 cm x 3.8 cm)
• Options: B335 Swivel Mounting Bracket. Use of this
bracket may decrease the PIR range and increase dead zones.
• Reading Bosch Security Systems, Inc. Product Date Codes
For Product Date Code information, refer to the Bosch Security
Systems, Inc. Web site at: http://www.boschsecurity.com/
datecodes/
.
3.3 Select a mounting location.
Mount the sensor where an
intruder will most likely cross
through the coverage pattern.
LED
ON
3.3.
3.4 Avoid.
3.3.
Direct Hot or
Cold
Drafts
Air
Conditioning
Outlets
Insert screwdriver here or here
Windows
and
Uninsulated
Walls
Moving Objects
Heat
Sources
Direct Sunlight
Mounting
Outdoors
Pets
7.5-9ft
3.3.
3.5 Position the detector at the correct height.
3.3.
7.5 - 9 ft.
(2.25 - 2.7 m)
Mount the detector 7.5 - 9 feet
(2.25 - 2.7 meters) above the floor
3.6 Mount the unit, using the appropriate
mounting holes.
Thinwall knockouts
for wiring
Corner Mount
Note:To avoid possible
circuit board
damage, use
only the
mounting
hardware
provided in the
appropriate
punch-out
mounting holes.
Be sure the vertical adjust tab
aligns with the correct mounting
height.
7.5-9ft
LED
ON
3.8 Wire the Detector.3.7 Install the board into the case.
9-15
VDC
-
Alarm
Contacts
+
(DS940T
only)
Tamper
Contacts
Surface
Remove
Mount
Areas
if using the
B335 Bracket
Don't overtighten the mounting screws
Cover may not attach correctly
3.9 Select LED Operation
LED
ON
7.5-9ft
ON
ON
7.5-9ft
N
ormally Closed (NC) contacts
3.10 If look-down is desired, peel away the look-down
mask. Do not remove the clear plastic lens.
LED
ON
7.5-9ft
LED
ON
OFF
4.0 Walk test the detector. This test should
be performed at the time of installation and
annually thereafter .
This detector contains an environmental
stabilization circuit which requires
approximately 2 minutes after initial
power-up to warm up. During this time
the detector will not respond to any
movement.
Please wait 2 minutes after initial power-
up to perform any walk tests.
© 2011 Bosch Security Systems, Inc.
130 Perinton Parkway, Fairport, New York 14450
www.boschsecurity.com
5.0 Coverage Patterns
Meters
0
20
1
2
10
0
10
10
20
Feet
0
10
11
20
Peel away
the mask
Meters
0
10
7.5
0
0
Feet
Look
Down
Although generally not required, if
12
masking is desired, the lens diagram
6
6777
5666
4555
2010
3444
2333
30
shows the appropriate areas to be
3
4
5
6
7
8
9
30
masked (see shaded area on the
DS940 lens diagram). Use an
opaque material (such as, electrical
tape) to mask the desired areas.
1 234567891011
0
12 22
23 33
34 44
45 55
56 66
67 77
DS940 Lens
(inside view)
40
6
DDS940/DS940T Installation Instructions
P/N: F01U035117-08 Page 2
1222
12
3
0
40
111
2/11