1.0 Description
The DS820i and DS820iT Series are high performance TriTech Passive Infrared (PIR)/Microwave (MW) Intrusion Detectors which use advanced signal processing to provide outstanding catch performance and unsurpassed false alarm immunity. They are designed to detect movement of a human body in the interior of a structure as it moves across the Detector’s field of view. When motion is detected, the Detector sends an alarm signal to the control panel. With Bosch Security Systems Pet Friendly numerous rodents or flying birds. This pet immunity feature has not been tested by Underwriters Laboratories.
2.0 Specifications
during walk testing and alarm). Use only Limited Power Source up to 5 A maximum.
• Standby Power: No internal standby battery.
installations, 4 hours (64 mAh) standby power must be provided
power supply.
• Alarm Relay: Silent operating Normally Closed reed relay. Contacts rated 3 W, 125 mA, 28 VDC maximum for DC resistive loads; and protected by a 4.7 , 1/2 W resistor in the common “C” leg of the relay. Do not use with capacitive or inductive loads.
• Temperature: The storage and operating temperature range is
-40°F to +120°F (-40°C to +49°C).
installations, the temperature range is +32°F to +120°F (0°C to +49°C).
3.0 Installation
3.1 Remove the cover using
a small flat-blade screwdriver.
®
pet immunity, these Detectors will not detect a dog up to 100 pounds (45 kg) or two 60 pound (27 kg) dogs, up to 10 cats,
Microwave Frequency:
DS820i/820iT: 10.525 GHz (UL Listed) DS820iTA: 10.687 GHz (Export only, not UL Listed)
DS820iTB: 9.9 GHz (Export only, not UL Listed)
For UL Certificated
by the control unit or by a Listed burglary
For UL Certificated
3.2 Press the vertical adjust tab
toward the side of the base and lift out the board.
Coverage: 20 ft. by 20 ft. (6 m by 6 m)
Tamper: (“T” models only) Normally Closed (with cover on). Contacts rated at 28 VDC, 125 mA max. Connect tamper circuit to a 24-hour protection circuit.
Options: B335 Low Profile Swivel Mount Bracket , B338 Ceiling Mount Bracket. (The use of brackets is not recommended for pet applications and may reduce range and increase dead zone areas).
Patents: This product is covered by one or more of the following U.S. patents: #4,660,024, #4,764,755, #5,077,548, #5,208,567, #5,262,783, #5,450,062, and #5,670,943.Other patents pending.
3.3 Select a mounting location. Mount the sensor where an intruder will most likely cross through the coverage pattern.
LED ON
3.4 Avoid:
Mounting Outdoors
Windows
and
Uninsulated
Walls
Optional anti-tamper screws at each end
Insert screwdriver here or here
Direct Sunlight
Direct Hot or Cold Drafts
Moving Objects
Bottom of Detector
7.5-9ft
7.5-9ft
3.5 Observe the Pet Immunity mounting recommendations.
NOTE: The upper areas are
not pet immune.
7.5 -9 ft.
(2.3 - 2.7 m)
Heat Sources
Air Conditioning Outlets
Mount the detector 7.5 to 9 feet
(2.3 to 2.7 meters) above the floo
LED ON
7.5-9ft
7.5-9ft
7.5-9ft
3
3
0
3.5 Mount the detector.
0
6
Meters
7
NOTE: To avoid possible circuit board damage, use only the mounting hardware provided in the
appropriate punch-out mounting holes.
Thinwall knockouts
for wiring
Corner Mount
Surface
Mount
Don't overtighte n the mounting screws
Cover may not att ach correctly
7.5 - 9 ft.
=
(2.3 - 2.7 m)
Remove
Areas
if using the
B335 Bracket
Do not use
the B335
Bracket in
pet
applications
3.6 Wire the detector.
+
Alarm
Contacts
(DS820iT
only)
6-15 VDC
-
Tamper
Contacts
LED
Normally Clos ed co ntacts
NOTE: Use only Limited Power Source
up to 5 A maximum.
3.7 Snap the board into the base so the notch aligns with the tab.
3.8 Select LED operation.
LED ON
LED ON
3.9 In non-pet applications only, if
look-down is desired, peel away the look-down mask. Do not
remove the clear plastic lens.
3.10 Microwave range is pre-set. Field
adjustment is not required.
NOTE: If you choose to adjust the range, set
the adjustment as low as possible for proper catch performance. Be sure to walk test throughout the coverage pattern after any adjustment.
INCREASE
Do not use excessive force when adjusting the microwave
7.5-9ft
7.5-9ft
ON
OFF
LED ON
7.5-9ft
7.5-9ft
Peel away
the mask
pot.
3.11 Walk test the detector. Perform this test at the time of installation and annually thereafter.
Green = PIR detect Yellow = MW detect
Red = Alarm
Microwave Coverage
PIR Coverage
This detector contains an environmental stabilization circuit which requires approximately 2 minutes after initial power-up to warm up. During this time the detector will not respond to any movement.
Please wait 2 minutes after initial power-up
to perform any walk tests.
5.0 FCC Notice
This device complies with Part 15 of the FCC Rules. Operation is subject to the following two conditions:
1) This device may not cause harmful interference.
2) This device must accept any interference, including interference that may cause undesired operation.
Changes or modifications not expressly approved by Bosch Security Systems can void the user’s authority to operate the equipment.
Bosch Security Systems Fairport, New York, USA 14450-9199 Customer Service: (800) 289-0096; Technical Support: (888) 886-6189
4.0 Coverage Patterns
0
10
0
10
Meters
1
11
10
2
10
0
.5
0
6
0
Look Down
Feet
67­77
56­66
10
45-5534-
44
3
4
5
6
7
Microwave Coverage
PIR Coverage
1234567891011
Although generally not required, the lens diagram shows the appropriate areas to be masked. Use an opaque material (such as, electrical tape) to
8
9
12 22 23 33 34 44 45 55 56 66
67 77
mask the desired areas.
DS820i Lens
200Feet
(inside view)
© 2003 Bosch Security Systems
DS820i/DS820iT Series Installation Instructions
P/N: 38055K 12/03 Page 2
23­33
12­22
LED ON
7.5-9ft
7.5-9ft
1­11
310
20
Loading...