Intrusion Alarm Systems | DS484Q and DS486Q Quad‑Beam Photoelectric Detectors
DS484Q and DS486Q Quad‑Beam
Photoelectric Detectors
www.boschsecurity.com
u Quad beams
u Easy alignment (sounder, LEDs, and voltage
readings)
The DS484Q and DS486Q Detectors have separate
transmitters and receivers. The transmitter sends an
invisible infrared beam to the receiver. If the beam is
broken, the receiver signals an alarm. Multiple channel
operation provides increased system flexibility.
Functions
Environmental Discrimination Circuitry
Monitors gradual loss of signal due to dust, fog, rain,
snow, and so on. Normally-closed output opens when
signal loss reaches 90%. Can be field configured to
bypass alarm relay when activated.
Test Features
The transmitters have three features for use in
alignment and testing.
• Voltage output (requires a voltmeter)
• Sounder for alignment
• LEDs (alignment)
u Two coverage ranges
u Four mounting options with optional mounting poles
u Environmental discrimination circuit
Multiple Channel Operation
Configure the detectors for up to eight different
channels. This allows multiple units to be used near
one another without the possibility of receiver crosstalk. This is particularly useful when stacking multiple
beam sets.
And-Or Mode Selection
You can configure the detectors to cause an alarm
when all four beams are blocked, or when either the
upper two beams or lower two beams are blocked.
This configuration detects smaller objects and
eliminates the possibility of someone crawling through
the beam.
Certifications and approvals
Region Certification
Europe CE 2004/108/EC EMC Directive;
EN61000-6-3:2007+A1:2011;
EN50130-4:2011
USA UL ANSR: Intrusion Detection Units
(UL639)
2 | DS484Q and DS486Q Quad‑Beam Photoelectric Detectors
Installation/configuration notes
Mounting Considerations
Mount these detectors on solid vibration free surfaces
or poles.
Technical specifications
Photobeam
Selectable Beams: Two groups by four channels
Maximum Outdoor
Coverage
DS484Q:
Maximum Outdoor
Coverage
DS486Q:
Response Time: Selectable response time of 35 ms to 700 ms
Beam Interrupt
Time:
120 m (400 ft)
200 m (660 ft)
Adjustable from 50 ms to 500 ms
Enclosure Design
Material: Polycarbonate
Dimensions: 398 mm x 103 mm x 99 mm
Receiver Weight: 1.2 kg (2.64 lb)
Transmitter
Weight:
(15.67 in. x 4.06 in. x 3.90 in.)
1.2 kg (2.64 lb)
Tamper Output: Normally-closed contacts rated at 0.1 A at
Alarm Output: Form C 0.2 A at 30 VDC, output period: 3 sec
EDC Output: Normally-closed 0.2 A at 30 VDC, output period:
Tamper Output: Normally-closed 0.1 A at 30 VDC, output period:
Environmental
Discrimination
Circuit Output:
30 VDC
3 sec
while cover is removed
Normally-closed contacts rated at 0.2 A at 30
VDC
Ordering information
DS484Q Photoelectric Detector
Provides an outdoor range of 120 m (400 ft), indoor
range 240 m (800 ft).
Order number DS484Q
DS486Q Photoelectric Detector
Provides an outdoor range of 200 m (660 ft), indoor
range 400 m (1320 ft).
Order number DS486Q
Accessories
MP1 Metal Pole, 1 m (3 ft)
Straight metal poles measuring 1 m (3 ft) for pole
mounting photoelectric detectors. Shipped in
packages of two.
Order number MP1
Environmental Considerations
Operating
Temperature:
IP Rating: IP 54 (protection against dust; protection against
-25° C to + 55° C (-13°F to + 130° F)
splashing water)
Mounting Considerations
Location: Surface or pole mount
Pattern
Pointability:
±90° horizontal, ±10° vertical
Power Requirements
Voltage: 10.5 VDC to 28 VDC non-polarized
Receiver Current
Draw:
DS484Q
Transmitter
Current Draw:
DS486Q
Transmitter
Current Draw:
Backup Power
Requirements:
80 mA standby, 50 mA alarm
35 mA
55 mA
4 hours (120 mAh) minimum required for UL
Certificated Installations
MP2 Metal Pole, 1.2 m (4 ft)
Straight metal poles measuring 1.2 m (4 ft) for pole
mounting photoelectric detectors. Shipped in
packages of two.
Order number MP2
MP3 L‑Curved Metal Pole
Curved metal poles for mounting to vertical surfaces
for pole mounting photoelectric detectors. Shipped in
packages of two.
Order number MP3
PC1A Weather Enclosure
Protects detectors when mounted outside. The
enclosure’s dimensions are 39.4 cm x 10.3 cm x 6 cm
(15.5 in. x 4 in. x 2.4 in.). Shipped in packages of two.
Order number PC1A
PC3A Back‑to‑back Box
Allows back-to-back mounting of detectors on a pole.
Shipped individually.
Order number PC3A
PEH‑2 Heater
Reduces the effects of frost, intense fog, cold, and
damp conditions on photoelectric beam detectors.
Shipped in packages of two (one for transmitter and
one for receiver).
Order number PEH2