Indoor only
▶
This single-beam photoelectric detector series consists of
the surface mount DS415i and DS435i Detectors with their
separate transmitters and receivers. The transmitter emits
one invisible infrared beam to the receiver. If the beam is
broken, the receiver signals an alarm. The detectors operate
in either AC/DC or DC-only mode according to the following
table:
Product AC DC
DS415i Detector
DS415iDC Detector
DS435i High Performance Detector
Functions
Alarm Memory (DS435i only)
Provides indication of stored alarms for use in multiple unit
applications by latching the alarm LED at the receiver.
Controlled by a switched voltage from the control panel.
Alarm Retransmission
Supervised alarm circuit transmitter that allows connection
of normally open or normally closed devices such as
magnetic contacts or relays from other detectors. Their
condition is relayed to the receiver by transmitter
shutdown.
• •
•
•
Inhibit Wiring (DS435i only)
Optional signal synchronization wire between transmitter
and receiver. Prevents receiver from being activated by
other sources such as another transmitter. Units must have
a common ground connection.
Test Features
Alarm LED
•
Margin test switch to assist with alignment
•
Certifications and Approvals
Region Certification
USA UL DS415i and DS435i: ANSR: Intrusion
Detection Units (UL639)
Technical Specifications
Photobeam
DS415i Range: 150 m (500 ft)
DS435i Range: 150 m ( t)
Enclosure Design
Dimensions: 16.2 cm x 7.7 cm x 6.6 cm (6.375 in. x 3 in. x 2.6 in.)
Material: High impact Lexan cover with die cast zinc base.
www.boschsecurity.com
2 | DS415i and DS435i Single Beam Photoelectric Detectors
Environmental Considerations
Operating Temperature: -18°C to +49°C (0°F to +120°F).
For UL installations the operating range is 0°C
to +49°C (+32°F to +120°F), indoor use.
Mounting
Location: Surface mount
Pointability: ±90° horizontal, ±20° vertical.
Power Requirements
Input Power:
AC Operation
•
DC Operation
•
12 VAC
8 VDC to 14.5 VDC
Transmitter Current Draw:
DS415i
•
AC Operation:
DC Operation:
DS415iDC and DS435i
•
DC Operation Only:
68 mA RMS with battery
8 mA at 12 VDC
8 mA at 12 VDC
Receiver Current Draw:
DS415i
•
AC Operation:
DC Operation:
DS415iDC
•
DC Operation Only:
DS435i
•
DC Operation Only:
95 mA RMS with battery
33 mA at 12 VDC
33 mA at 12 VDC
20 mA at 12 VDC
Alarm Output: Form C contacts rated at 3.0 W,
125 mA at 28 VDC for resistive loads.
Tamper Output: Form A contact rated 125 mA at
28 VDC.
Trademarks
Trademark names are used throughout this document. In
most cases, these designations are claimed as trademarks
or registered trademarks in one or more countries by their
respective owners. Rather than placing a trademark symbol
in every occurrence of a trademark name, Bosch Security
Systems, Inc. uses the names only in an editorial fashion
and to the benefit of the trademark owner with no intention
of infringing the trademark.
Ordering Information
DS415i Detector
Provides AC/DC operation and battery backup. Includes a P333 Standby Battery. The
range is 150 m (500 ft).
DS415iDC Detector
Provides DC operation only. The range is 150
m (500 ft).
DS435i High Performance Detector
Provides DC operation only, alarm memory,
and inhibit wiring. The range is 150 m (500 ft).
Accessories
P333 Rechargeable Battery Pack
Rechargeable (Nickel-Cadmium) battery pack
rated for 3.6 V, 0.65 Ah.
TC6000 Test Cord
Test cord for connecting a compatible detector’s test pins to a voltmeter. It is 4.6 m (15 ft)
long.
TR12 Transformer
12 VAC, 0.93 A transformer.
DS415i
DS415iDC
DS435i
P333
TC6000
TR12
Lexan is either a trademark or registered trademark of General Electric
Company in the United States and other countries.
Americas:
Bosch Security Systems, Inc.
130 Perinton Parkway
Fairport, New York, 14450, USA
Phone: +1 800 289 0096
Fax: +1 585 223 9180
security.sales@us.bosch.com
www.boschsecurity.us
© Bosch Security Systems Inc. 2010 | Data subject to change without notice
T1171564299 | Cur: en-US, V15, 2 Jul 2010
Europe, Middle East, Africa:
Bosch Security Systems B.V.
P.O. Box 80002
5600 JB Eindhoven, The Netherlands
Phone: + 31 40 2577 284
Fax: +31 40 2577 330
emea.securitysystems@bosch.com
www.boschsecurity.com
Asia-Pacific:
Robert Bosch (SEA) Pte Ltd, Security Systems
11 Bishan Street 21
Singapore 573943
Phone: +65 6258 5511
Fax: +65 6571 2698
apr.securitysystems@bosch.com
www.boschsecurity.com
Represented by