GREENSTAR CDi
WALL HUNG RSF GAS-FIRED CONDENSING COMBINATION BOILER
FOR SEALED CENTRAL HEATING SYSTEMS AND MAINS FED DOMESTIC HOT WATER
THE APPLIANCE IS FOR USE
WITH NATURAL GAS OR L.P.G.
(Cat II 2H3P TYPE C13 & C33)
25CDi GC-Number 47-311-92 30CDi GC-Number 47-311-93 35CDi GC-Number 47-311-94 40CDi GC-Number 47-311-95
USER INSTRUCTIONS & CUSTOMER CARE GUIDE
Page 2
CONTACT INFORMATION
WORCESTER BOSCH:
TECHNICAL: 08705 266241
SERVICE: 08457 256206
SPARES: 01905 752571
LITERATURE: 01905 752556
TRAINING: 01905 752526
SALES: 01905 752640
WEBSITE:
www.worcester-bosch.co.uk
WATER TREATMENT:
FERNOX 01799 550811 www.fernox.com
SENTINEL 0151 420 9595 www.betzdearborn.com/sentinel
FLUE TERMINAL GUARDS:
TOWER FLUE COMPONENTS Vale Rise, Tonbridge TN9 1TB
USER INSTRUCTIONS & CUSTOMER CARE GUIDE
PLEASE READ THESE INSTRUCTIONS CAREFULLY BEFORE OPERATING YOUR APPLIANCE
THESE INSTRUCTIONS ARE APPLICABLE TO THE WORCESTER BOSCH APPLIANCE MODEL(S) STATED ON THE FRONT COVER OF THIS MANUAL ONLY AND MUST NOT BE USED WITH ANY OTHER MAKE OR MODEL OF APPLIANCE.
THE INSTRUCTIONS APPLY IN THE UK ONLY AND SHOULD BE FOLLOWED EXCEPT FOR ANY STATUTORY OBLIGATION.
IF YOU ARE IN ANY DOUBT CONTACT THE WORCESTER BOSCH TECHNICAL HELPLINE.
DISTANCE LEARNING AND TRAINING COUR­SES ARE AVAILABLE FROM WORCESTER BOSCH.
THIS APPLIANCE MUST BE INSTALLED BY A COMPETENT PERSON. FAILURE TO INSTALL CORRECTLY COULD LEAD TO PROSECUTION.
PLEASE LEAVE THIS GUIDE, THE INSTALLA­TION INSTRUCTIONS AND THE COMPLETED BENCHMARK LOG BOOK WITH THE USER OR AT THE GAS METER AFTER INSTALLATION.
ABBREVIATIONS USED IN THIS BOOK:
NG - Natural Gas LPG - Liquid Petroleum Gas CH - Central Heating SEDBUK - Seasonal Efficiency of Domestic Boilers in the United Kingdom
2
USER INSTRUCTIONS & CUSTOMER CARE GUIDE
TER BOSC H GREENSTAR 25CDi/30CDi/35CDi/40CDi
S
E
C
R
O
W
6 7
20 611 928a (02/05)
Page 3
CONTENTS
INTRODUCTION
EXCELLENCE COMES AS STANDARD 4 SAFETY PRECAUTIONS 5-7 GENERAL NOTES 8-11
USING YOUR APPLIANCE
CONTROLS 12 OPERATING THE APPLIANCE 13-15
Switching the appliance on/off 13 Setting the central heating temperature 13 Controlling central heating 13 Frost protection 14 Controlling domestic hot water 14-15 Fault condition 15
ENERGY SAVING
TIPS ON ENERGY SAVING 16-17
MAINTENANCE
MAINTAINING YOUR APPLIANCE 18 FAULT FINDING 19 FAULT OR BREAKDOWN 20-21
GUARANTEE
YOUR GUARANTEE 22 GUARANTEE REGISTRATION 23
USING YOUR
ENER GY
INTRODUCTION
APPLIANCE
AVING S
MAINTENANC E
E
ANTE AR
U G
OSCH GREENSTAR 25CDi/30CDi/35CDi/40CDi
R B
TE
S
WORCE
6 720 611 928a (02/05)
CONTENTS
3
Page 4
EXCELLENCE COMES AS STANDARD
INTRODUCTI ON
Thank you for purchasing a Greenstar 25CDi/30CDi/35CDi/40CDi gas-fired condensing combination boiler manu­factured by Worcester Bosch. The com­pany prides itself on manufacturing boi­lers to the strictest quality control stan­dards throughout every stage of produc­tion. Worcester Bosch has led the field in innovative appliance design and per­formance for more than 40 years. This heritage means all products are of exceptional quality and proven reliability.
The Greenstar range in particular is extremely energy efficient, converting up to 97% of gas consumed into heat, offe­ring you economical running costs and value for money. It sits in SEDBUK Band A, and is therefore amongst the top energy rated appliances available.
There is also the reassurance of our no­nonsense 2 years parts and labour gua­rantee - backed up by Worcester Total Cover, an optional complete maintenan­ce scheme to keep your boiler operating at peak condition and efficiency.
To find out more about Worcester Bosch log onto www.worcester­bosch.co.uk.
4
EXCELLENCE COMES AS STANDARD
TER BOSCH GREENSTAR 25CDi/30CDi/35CDi/40CDi
S
E
C
R
O
W
6 7
20 611 928a (02/05)
Page 5
SAFETY PRECAUTIONS
IF YOU SMELL GAS:
6 DON’T SMOKE OR STRIKE
MATCHES
6 DON’T TURN ELECTRICAL
SWITCHES ON OR OFF
4 DO PUT OUT NAKED FLAMES 4 DO OPEN DOORS AND
WINDOWS
4 DO KEEP PEOPLE AWAY FROM
THE AREA AFFECTED
4 DO TURN OFF THE CONTROL
VALVE AT THE METER
4 TELEPHONE YOUR GAS
COMPANY
BENCHMARK STANDARD
INTRODUCTI ON
‘Benchmark’ is a code of practice for correctly installing, commissioning and servicing of domestic water heating appliances.
A Benchmark Checklist is provided by the manufacturer for the installer to complete ALL details together with their CORGI registration number and sign to confirm that the boiler has been instal­led and commissioned according to the manufacturer’s instructions.
IMPORTANT: The completed Benchmark Checklist will be required in the event of any warranty work and may be required by the local Building Control Inspector.
HEALTH & SAFETY
The appliance contains no asbestos and no substances used in the construction process that contravene the COSHH Regulations (Control of Substances Hazardous to Health Regulations 1988).
OSCH GREENSTAR 25CDi/30CDi/35CDi/40CDi
R B
TE
S
WORCE
6 720 611 928a (02/05)
SAFETY
PRECAUTIONS
5
Page 6
SAFETY PRECAUTIONS
COMBUSTIBLE AND CORROSIVE
INTRODUCTION
MATERIALS
Do not store or use any combustible materials (paper, thinners, paints etc.) inside or within the vicinity of the appli­ance.
Chemically aggressive substances, such as halogenated hydrocarbons containing chlorine or fluorine compounds can cor­rode the appliance and invalidate any warranty.
FITTING & MODIFICATIONS
Fitting the appliance, any controls to the appliance and removal of the outer casing may only be carried out by a competent engineer in accordance with the Gas Safety (Installation and Use) Regulations.
Flue systems must not be modified in any way other than as described in the Installation Instructions and any misuse or unauthorised modifications to the appliance, flue or associated compo­nents and systems could invalidate the warranty. The manufacturer accepts no liability arising from any such actions. This does not affect your statutory rights.
6
SAFETY PRECAUTIONS
TER BOSCH GREENSTAR 25CDi/30CDi/35CDi/40CDi
S
E
C
R
O
W
6 7
20 611 928a (02/05)
Page 7
SAFETY PRECAUTIONS
SERVICING
The user is recommended to have the system regularly serviced by a compe­tent, qualified engineer (such as British Gas or CORGI registered personnel) using original spares, to help maintain the economy, safety and reliability of the appliance and to have the Service Record completed in the Benchmark Checklist.
The appliance should be serviced annu­ally after installation unless the particular installation conditions and usage demand more frequent services.
IMPORTANT - ensure that the service engineer completes the Service Record in the Benchmark Checklist after each service.
INTRODUCTION
OSCH GREENSTAR 25CDi/30CDi/35CDi/40CDi
R B
TE
S
WORCE
6 720 611 928a (02/05)
SAFETY
PRECAUTIONS
7
Page 8
GENERAL NOTES
To get the best from your appliance plea-
INTRODUCTION
se read these instructions carefully.
SEALED HEATING SYSTEMS
This appliance is fitted to a sealed hea­ting system which is pre-pressurised. Your installer will advise you of the mini­mum and maximum pressure which should be indicated on the pressure gauge.
Check regularly that the pressure is maintained and contact your installer or maintenance engineer if a permanent significant drop in pressure is indicated on the pressure gauge. If the system loses pressure it should be re-pressuri­sed and the cause of the fall investiga­ted.
CENTRAL HEATING SYSTEMS
During the first few hours of operation of the central heating system, check that all radiators are being heated at an even rate. If the top of a radiator is at a lower temperature than the bottom then it should be vented by releasing air through the venting screw at the top of the radiator. Ask your installer to show you how this is done.
This boiler is fitted to a sealed system; repeated venting will reduce the quantity of water in the system and this must be
8
GEN ERAL NOTES
TER BOSCH GREENSTAR 25CDi/30CDi/35CDi/40CDi
S
E
C
R
O
W
6 7
20 611 928a (02/05)
Page 9
mm
mm
+ 30mm
above elbow
5mm
5mm
600mm
200mm
*600mm
(**20mm)
GENERAL NOTES
replenished for safe and satisfactory operation of the appliance.
Should water leaks be found in the system or if excessive venting is requi­red, then a service engineer must be contacted to inspect the installation and rectify any fault.
Only additives that are compatible with aluminium may be used in the system. Any incompatible additive used will inva­lidate the guarantee.
CONDENSATE DRAIN
This is a condensing appliance and the terminal will, at times give out a plume of water vapour. This is quite normal.
The appliance also produces quantities of condensate which is discharged regu­larly by a siphon within the boiler via a pipe to drain. This pipe must not be blocked or altered in any way.
CLEARANCES - VENTILATED COMPARTMENT
Your installer will have provided adequa­te space around the appliance for safety and servicing access. Do not restrict this space with the addition of cupboards, shelves etc. next to the appliance.
*600 mm service clearance required to a fixed surface (**20 mm from removable door or panel)
INTRODUCTION
R B
TE
S
WORCE
6 720 611 928a (02/05)
OSCH GREENSTAR 25CDi/30CDi/35CDi/40CDi
GENERAL NOTES
9
Page 10
+ 250mm
above elbow
100mm*
100mm*
300mm
100mm**
to removable door
600mm***
front clearance for service
+ 30mm
above elbow
200mm*
200
mm*
100mm**
600
mm***
200mm
A
INTRODUCTION
B
10
GEN ERAL NOTES
GENERAL NOTES
BOILER CLEARANCES ­UNVENTILATED COMPARTMENT
The diagrams (A and B) opposite show two options for the minimum space required to install and service the boiler inside an unventilated compartment.
* This space can be reduced to 50 mm for one side only as long as both the side clearances add up to the total of both the side measurements shown or more.
** Space required for unventilated areas with a removable door or panel.
*** 600 mm clearance required to a fixed surface for servicing.
ROOM THERMOSTAT
A room temperature controller and pro­grammer should be fitted to control the central heating. Refer to the instructions supplied with the thermostat for informa­tion on siting and setting.
THERMOSTATIC RADIATOR VALVES
It is recommended that this type of valve is fitted to all but one of the radiators (or at least those in the sleeping accommo­dation). The remaining radiator, which
TER BOSCH GREENSTAR 25CDi/30CDi/35CDi/40CDi
S
E
C
R
O
W
must be where the room thermostat is located, should be uncontrolled and must be left open. The thermostatic radiator valves should conform to the requirements of BS2767:10.
6 7
20 611 928a (02/05)
Page 11
GENERAL NOTES
VENTILATION
This is a room sealed appliance and does not require any air for combustion from inside the property. If the appliance is fitted into a cupboard or a compart­ment is built around the appliance after installation, then the compartment must be separated from the boiler space by a perforated non-combustible partition as described in BS 6798.
Notwithstanding the requirements of BS 6798 and BS 5440 there is no need for ventilation openings to be provided in the compartment because of the low heat loss from the appliance casing, if the clearances shown are maintained.
Do not operate the appliance if the flue terminal fitted on the outside wall or roof is obstructed or damaged.
PUMP ANTI-SEIZURE
If there has been no heating demand for 24 hours the boiler will run the system pump for a few seconds to reduce the possibility of pump seizure during long periods of inactivity, which is usually more frequent during the summer months.
INTRODUCTION
OSCH GREENSTAR 25CDi/30CDi/35CDi/40CDi
R B
TE
S
WORCE
6 720 611 928a (02/05)
GENERAL NOTES
11
Page 12
A
D
F
L
C
B
G
H
M
E
I
K
J
6 720 611 928-01.1O
minmin
5
CONTROLS
APPLIANCE
USING YOUR
A - MASTER SWITCH FOR ON/OFF
B - MAINS ON/OFF INDICATOR +
FAULT DIAGNOSTICLIGHT
C - CENTRAL HEATING TEMPERA-
TURE CONTROL
D - BURNER ON INDICATOR LIGHT
(GREEN)
E - FAULT RESET BUTTON
F - SERVICE BUTTON
G - DOMESTIC HOT WATER TEMPE-
RATURE CONTROL
12
CONTROLS
R
O
W
H - ECO BUTTON (DOMESTIC HOT
WATER PRE-HEAT ON/OFF)
I - SYSTEM PRESSURE GAUGE
J - POSITION FOR OPTIONAL
PROGRAMMER
K - DISPLAY
L - CENTRAL HEATING BOOST
BUTTON
M - HOLIDAY BUTTON
TER BOSCH GREENSTAR 25CDi/30CDi/35CDi/40CDi
S
E
C
20 611 928a (02/05)
6 7
Page 13
OSCH GREENSTAR 25CDi/30CDi/35CDi/40CDi
R B
TE
S
WORCE
6 720 611 928a (02/05)
OPERATING THE APPLIANCE
SWITCHING THE APPLIANCE ON/OFF Switching on
B Switch on the appliance by pressing the master switch. The indicator light shows blue
• The boiler runs for 15 minutes at mini­mum heating output to fill the conden­sate trap, the display (K) alternates bet­ween “-II-” and the central heating flow temperature. This occurs every time the mains supply has been interrupted.
Switching off
B Switch off the appliance by pressing the master switch. The blue indicator light goes out.
SETTING THE CENTRAL HEATING TEMPERATURE
B Turn the central heating temperature control to the desired level, between 40 °C and 90 °C.
B When the burner is lit, the green indi­cator light underneath the on/off switch is illuminated.
CONTROLLING CENTRAL HEATING
B Set the timer to the correct time.
B Set room thermostat to the desired
room temperature.
B Set the thermostatic radiator valves to the desired settings.
OPERATING THE
APPLIANCE
13
APPLIANCE
USING YOUR
Page 14
OPERATING THE APPLIANCE
FROST PROTECTION
B Leave master switch on.
B Turn the central heating temperature
control to .
APPLIANCE
USING YOUR
If the temperature falls to 5 °C within the boiler it will fire to avoid the possibility of freezing.
B Add a suitable anti-freeze fluid to the water in the central heating system.
B If remote pipework is likely to be sub­jected to freezing conditions, ensure the installer has fitted a frost thermostat in the area to protect the pipework.
CONTROLLING THE HOT WATER TEMPERATURE
B The hot water temperature can be set to between approx. 40 °C and 60 °C using the temperature control .
DOMESTIC HOT WATER PRE-HEAT
Pre-heat reduces the time taken to pro­duce hot water at the tap and is control­led by the ECO button.
B Press the ECO button to select either:
When the ECO button
the boiler will be in pre-heat mode
ted
is not illumina-
14
OPERATING THE APPLIANCE
TER BOSCH GREENSTAR 25CDi/30CDi/35CDi/40CDi
S
E
C
R
O
W
6 7
20 611 928a (02/05)
Page 15
OPERATING THE APPLIANCE
(which will reduce the time taken to pro­duce hot water at the tap).
OR
When the ECO button is illuminated the boiler will be in ECO mode with no pre-heat available.
FAULT CONDITION
In the unlikely event of a fault occurring while the appliance is in operation:
The reset button will flash once per second and the mains indicator (blue light) will flash also. The display shows a fault code.
B To reset boiler press the reset button.
The reset button will no longer be illumi­nated and the mains indicator will stop flashing.
The boiler will function normally, depen­dent on programmer and room thermo­stat settings.
If the fault remains and cannot be clea­red by pressing the reset button, or if fault persists contact Worcester Bosch for assistance, giving a description of the fault and, if possible, the fault code from the display.
APPLIANCE
USING YOUR
OSCH GREENSTAR 25CDi/30CDi/35CDi/40CDi
R B
TE
S
WORCE
6 720 611 928a (02/05)
OPERATING THE
APPLIANCE
15
Page 16
TIPS ON ENERGY SAVING
Heating economically
The boiler is designed to provide a high level of comfort while keeping gas con­sumption and the resulting environmen­tal effect as low as possible. The gas supply to the burner is controlled accor­ding to the level of demand for heat. The boiler continues to operate with a low flame if the demand for heat redu­ces. The technical term for this process is modulating control. Modulating con-
SAVING
ENERGY
trol reduces temperature fluctuations and provides even distribution of heat throughout the home. This means that the boiler may stay on for relatively long periods but will use less gas than an appliance that continually switches on and off.
Central heating systems with room thermostats/thermostatic radiator valves
The central heating control on the boiler should be set to the maximum rated tem­perature of the central heating system.
The temperature of each room can be set individually (except primary room with the room thermostat) using the thermo­static radiator valves.
Roof insulation
Around 30% of the heat loss from a pro­perty is through the roof. Replace any old insulation with new insulation, prefe­rably of around 200 mm thickness or more.
Window frames
Single glazed windows, particularly those with steel frames, can lose a great deal of heat. Consideration should be given to replacement with PVCu or woo­den framed double glazed units.
Curtains
Lined curtains, or heavier full length cur­tains can provide excellent insulation. However, always ensure that the curtains do not drape over radiators.
16
TIPS ON ENERGY SAVING
TER BOSCH GREENSTAR 25CDi/30CDi/35CDi/40CDi
S
E
C
R
O
W
6 7
20 611 928a (02/05)
Page 17
TIPS ON ENERGY SAVING
Draughts
Try to ensure that draughts around doors, windows, letterboxes and keyho­les etc. are reduced by using a suitable draught excluder. Warning - Do not block or seal any air vents that are installed to ensure the central heating boiler opera­tes safely.
Room thermostats
Reducing the setting of the room ther­mostat by 1 °C can reduce fuel con­sumption by up to 10%.
New control systems
Upgrade your heating control system if necessary with the latest equipment available. The minimum level of control is a programmer, interlocking room thermo­stat and thermostatic radiator valves.
Radiators
More often than not radiators will be sited underneath a window, so the warm air from the radiator heats the colder incoming air from the window. The per­formance of the radiator will be affected if the curtains are allowed to drape over the radiator or shelves are fitted above it. The positioning of furniture and tables in front of the radiator should also be avoi­ded.
It is advisable to manually adjust all radiator thermostatic valves every 2-3 months to prevent them sticking. It is also important that the plastic tops of all valves are always in position and not cracked or damaged to prevent acci­dents. Care should be taken when vacu­um cleaning carpets to avoid damage to valves and pipework.
The heating system and the outputs of the radiators have been carefully selec­ted by your installer. The temperature obtainable in any given room is depen­dent on all radiators being operated at the same time. If you decide to turn off radiators in unused rooms, spare bedrooms etc., you may experience slightly lower room temperatures in rooms adjacent to unheated rooms.
AVING S
ENERGY
OSCH GREENSTAR 25CDi/30CDi/35CDi/40CDi
R B
TE
S
WORCE
6 720 611 928a (02/05)
TIPS ON ENERGY
SAVING
17
Page 18
MAINTAINING YOUR APPLIANCE
Your new Greenstar 25CDi/30CDi/ 35CDi/40CDi gas-fired appliance repre­sents a long term investment in a reliab­le, high quality product.
In order to realise its maximum working life, and to ensure it continues to opera­te at peak efficiency and performance, it is essential that your boiler receives regular servicing and maintenance checks from a competent person beyond the initial 2 year guarantee period.
If you would like to know more about a Worcester Bosch service contract, plea­se tick the appropriate box on your war-
MAINTENANC E
ranty registration card.
If your Greenstar 25CDi/30CDi/ 35CDi/40CDi should fail to operate cor­rectly or requires servicing please con­tact the Worcester Bosch Service Department (see inside front cover for details).
Details of the boiler including the Gas Council number can be found under the controls cover flap on the boiler.
18
MAINTAINING YOUR APPLIANCE
TER BOSCH GREENSTAR 25CDi/30CDi/35CDi/40CDi
S
E
C
R
O
W
6 7
20 611 928a (02/05)
Page 19
FAULT FINDING
This table gives information on basic operating system problems.
In the unlikely event of a boiler fault please read the following page tho­roughly before contacting Worcester Bosch.
Problem Cause Remedy
Desired room temperature is not reached
Desired room temperature exceeded by large amount
Heating stays on for too long
No on/off indicator Momentary power failure Switch off appliance at
Hot water temperature too low
Hot water temperature too high
Thermostatic radiator valve(s) set too low
Temperature control for CH flow on boiler set too low
Air trapped in heating system
Increase thermostatic radiator valve setting(s)
Increase CH flow tempera­ture control setting
Bleed radiators and rechar­ge heating system
Radiators are too hot Turn down thermostatic
radiator valves / room ther­mostat
Reduce central heating temperature on boiler
Clock is incorrectly set Check setting
master switch, wait a few seconds then switch on again
Temperature set too low
Programmer setting
Water flow at tap too high
Check setting
Check setting
Reduce flow rate at tap
Temperature set too high Check setting
MAINTENANCE
OSCH GREENSTAR 25CDi/30CDi/35CDi/40CDi
R B
TE
S
WORCE
6 720 611 928a (02/05)
FAULT FINDING
19
Page 20
FAULT OR BREAKDOWN
This appliance is supported in the UK by Worcester, Bosch Group.
Specialist factory trained Service Engineers are available to attend a breakdown occurring on this appliance.
No charge will be made for parts and/or labour providing:
B An appliance fault is found and the appliance has been installed within the past 24 months. Reasonable evidence of this must be supplied on request. i.e. the Benchmark Checklist.
A call-out charge will be made where:
MAINTENANC E
B The appliance has been installed for over 24 months.
OR
B Evidence cannot be provided that the first year service inspection has been carried out (ie. an entry in the Benchmark Checklist).
OR
B Our Field Service Engineer finds no fault with the appliance (see Note).
OR
B The cause of breakdown is misuse or with other parts of your plumbing/hea­ting system, or with equipment not sup­plied by Worcester Bosch.
20
FAULT OR BREAKDOWN
TER BOSCH GREENSTAR 25CDi/30CDi/35CDi/40CDi
S
E
C
R
O
W
6 7
20 611 928a (02/05)
Page 21
FAULT OR BREAKDOWN
Note: NO APPLIANCE FAULT IS FOUND ON OVER 30% OF ALL SERVICE CALL OUTS.
Please read this guide carefully to gain a good understanding of the operation of your appliance. In the case of a suspec­ted fault, refer to the fault finding section of this guide.
If in doubt contact our Technical Helpline
In the event of an appliance fault or breakdown please contact our Service Department. Your service administrator will arrange for an engineer to call with the minimum of delay; under normal cir­cumstances this will be from 1 - 3 wor­king days (excluding weekends) for prio­rity breakdown situations (no hot water and/or heating).
Invoices for attendance and repair work carried out on this appliance by any third party will not be accepted.
MAINTENANCE
OSCH GREENSTAR 25CDi/30CDi/35CDi/40CDi
R B
TE
S
WORCE
6 720 611 928a (02/05)
FAULT OR
BREAKDOWN
21
Page 22
YOUR GUARANTEE
This appliance is guaranteed against faulty material or workmanship for a period of 2 years from the date of instal­lation subject to the following terms and conditions.
B Your Guarantee Registration Card must be returned within 30 days for the second year of your guarantee to beco­me valid.
B During the period of this guarantee any components of the unit which are proven to be faulty or defective in manu­facture will be exchanged or repaired free of charge by BBT Thermotechnology UK Ltd.
E
ANTE AR
U G
B The householder may be asked to prove the date of installation, that the appliance was correctly commissioned and, where appropriate, the first year’s service has been carried out to the satis­faction of BBT Thermotechnology UK Ltd. when requested. These should be part of the Benchmark Checklist.
B Any product or part returned for servi­cing under the guarantee must be accompanied by a claim stating the model, serial number & date of installa­tion.
B BBT Thermotechnology UK Ltd. will not accept responsibility for damage caused by faulty installation, neglect, misuse or accidental damage or the non­observance of the instructions contained in the Installation and Servicing Manual and User Instructions.
B The appliance has been used only for the normal domestic purposes for which it was designed.
B This guarantee applies only to equip­ment purchased and used in the United Kingdom.
This guarantee does not affect your sta­tutory rights.
22
YOUR GUARANTEE
TER BOSCH GREENSTAR 25CDi/30CDi/35CDi/40CDi
S
E
C
R
O
W
6 7
20 611 928a (02/05)
Page 23
Model
GUARANTEE REGISTRATION
You should complete and return the postpaid Guarantee Registration Card within 14 days of purchase.
Returning the card will register you as the owner of your new Greenstar 25CDi/30CDi/35CDi/40CDi appliance and will assist us in maintaining an effective and efficient customer service by establishing a reference and perma­nent record for your boiler.
This does not affect your statutory rights.
For your own record:
Serial No.
(See guarantee card)
Type / size
Date of installation
OSCH GREENSTAR 25CDi/30CDi/35CDi/40CDi
R B
TE
S
WORCE
6 720 611 928a (02/05)
Check that the Benchmark Checklist has been completed by your installer or service engineer.
GUARANTEE
REGISTRATION
23
E
ANTE AR
U G
Page 24
USER INSTRUCTIONS & CUSTOMER CARE GUIDE
Worcester, Bosch Group Cotswold Way, Warndon, Worcester WR4 9SW. Tel. 01905 754624 Fax. 01905 754619
www.worcester-bosch.co.uk
Worcester Bosch Group is a trading name of BBT Thermotechnology UK Ltd.
6 720 611 928a (02/05) OSW