AUTODOME IP starlight 5100i IRTable of contents | en3
Table of contents
1
Safety4
1.1About this manual4
1.2Legal information4
1.3Safety precautions4
1.4Important safety instructions5
1.5Connection in applications7
1.6Important notices8
1.7Important notices - illumination safety8
1.8Customer support and service9
2
Introduction11
2.1Parts List11
2.2Additional Products Required11
2.3Additional tools required11
2.4Establishing the connection12
2.5Configuration with Project Assistant app12
3
4
5
Product Description13
Preparing Wiring14
(Optional) Configuration Programming on a Temporary Table-top Stand15
5.1Installation Overview15
5.2Configuration Programming on a Temporary Table-top Stand15
6
7
8
9
(Optional) Installing a microSD card17
Installing the IP66 kit19
(Optional) Installing the Surveillance Cabinet22
Installing a Pendant Wall Mount and Camera23
9.1Installing a Pendant Wall Mount (with the Surveillance Cabinet)23
9.2Attaching the Mounting Cap and the Camera24
10
Installing a Parapet Roof Mount and Camera31
10.1Installing the Roof Mount31
10.2Attaching the Mounting Cap and the Camera33
11
Installing a Pipe Mount and Camera39
11.1Preparing the Ceiling for Installation39
11.2Installing the Pipe Mount39
11.3Attaching the Mounting Cap and the Camera40
12
13
14
Connection46
Maintenance48
Decommissioning49
14.1Transfer49
14.2Disposal49
15
16
Technical data50
Support51
Bosch Security Systems
Installation Manual
2021-02-19 | 0.7 |
4en | SafetyAUTODOME IP starlight 5100i IR
!
!
i
1Safety
1.1About this manual
This manual has been compiled with great care and the information it contains has been
thoroughly verified. The text was complete and correct at the time of printing. Because of the
ongoing development of products, the content of the manual may change without notice.
Bosch Security Systems accepts no liability for damage resulting directly or indirectly from
faults, incompleteness, or discrepancies between the manual and the product described.
1.2Legal information
Copyright
This manual is the intellectual property of Bosch Security Systems, and is protected by
copyright. All rights reserved.
Trademarks
All hardware and software product names used in this document are likely to be registered
trademarks and must be treated accordingly.
1.3Safety precautions
In this manual, the following symbols and notations are used to draw attention to special
situations:
Danger!
High risk: This symbol indicates an imminently hazardous situation such as “Dangerous
Voltage” inside the product. If not avoided, this will result in an electrical shock, serious
bodily injury, or death.
Warning!
Medium risk: Indicates a potentially hazardous situation. If not avoided, this may result in
minor or moderate injury.
Caution!
Low risk: Indicates a potentially hazardous situation. If not avoided, this may result in
property damage or risk of damage to the unit.
Notice!
This symbol indicates information or a company policy that relates directly or indirectly to the
safety of personnel or protection of property.
2021-02-19 | 0.7 |
Installation Manual
Bosch Security Systems
AUTODOME IP starlight 5100i IRSafety | en5
!
!
!
1.4Important safety instructions
Read, follow, and retain for future reference all of the following safety instructions. Follow all
warnings before operating the device.
1.Clean only with a dry cloth. Do not use liquid cleaners or aerosol cleaners.
2.Do not install device near any heat sources such as radiators, heaters, stoves, or other
equipment (including amplifiers) that produce heat.
3.Never spill liquid of any kind on the device.
4.Take precautions to protect the device from power and lightning surges.
5.Adjust only those controls specified in the operating instructions.
6.Operate the device only from the type of power source indicated on the label.
7.Unless qualified, do not attempt to service a damaged device yourself. Refer all servicing
to qualified service personnel.
8.Install in accordance with the manufacturer's instructions in accordance with applicable
local codes.
9.Use only attachments/accessories specified by the manufacturer.
10. Protect all connection cables from possible damage, particularly at connection points.
Caution!
TO REDUCE THE RISK OF ELECTRIC SHOCK, DISCONNECT THE POWER SOURCE WHILE
INSTALLING THE DEVICE.
Caution!
Installation must be made by qualified personnel and conform to ANSI/NFPA 70 (the National
Electrical Code® (NEC)), Canadian Electrical Code, Part I (also called CE Code or CSA C22.1),
and all applicable local codes. Bosch Security Systems accepts no liability for any damages or
losses caused by incorrect or improper installation.
Warning!
Risk of bodily injury, property damage, or damage to the unit
Because of the weight of the camera, do not use the optional extension pipe (NDA-U-PMTE)
to extend the pipe while using the pipe mount (NDA-U-PMT or NDA-U-PMTS).
All-pole power switch - Incorporate an all-pole power switch, with a contact separation of at
least 3mm, into the electrical installation of the building. If it is needed to open the housing,
use this all-pole switch as the main disconnect device for switching off the voltage to the unit.
Camera signal - Protect the cable with a primary protector if the camera signal is beyond 140
feet, in accordance with NEC800 (CEC Section 60).
Fuse rating - For security protection of the device, the branch circuit protection must be
secured with a maximum fuse rating of 16A. This must be in accordance with NEC800 (CEC
Section 60).
Ventilation – Any openings in the device / enclosure are provided for ventilation to prevent
overheating and to ensure reliable operation. Do not block or cover these openings. Do not
place the device in an enclosure unless proper ventilation is provided, or the manufacturer’s
instructions have been adhered to.
Outdoor signals - The installation for outdoor signals, especially regarding clearance from
power and lightning conductors and transient protection, must be in accordance with NEC725
and NEC800 (CEC Rule 16-224 and CEC Section 60).
Power disconnect - When PoE (802.3bt) supplies power to the unit, the Ethernet cable is the
main device to disconnect power for all units.
Bosch Security Systems
Installation Manual
2021-02-19 | 0.7 |
6en | SafetyAUTODOME IP starlight 5100i IR
i
!
i
i
When PoE is not used, the power cord (connected to the 24 VAC power source) is the main
device to disconnect power for all units.
Grounding:
- Connect outdoor equipment to the unit's inputs only after this unit has had its ground
terminal connected properly to a ground source.
- Disconnect the unit's input connectors from outdoor equipment before disconnecting the
grounding terminal.
- Follow proper safety precautions such as grounding for any outdoor device connected to this
unit.
U.S.A. models only - Section 810 of the National Electrical Code, ANSI/NFPA No.70, provides
information regarding proper grounding of the mount and supporting structure, size of
grounding conductors, location of discharge unit, connection to grounding electrodes, and
requirements for the grounding electrode.
Video loss - Video loss is inherent to digital video recording; therefore, Bosch Security
Systems cannot be held liable for any damage that results from missing video information.
To minimize the risk of losing information, we recommend multiple, redundant recording
systems, and a procedure to back up all analog and digital information.
Notice!
Risk of water ingress
Securely seal all fittings and connection points between the device and all mounts to ensure a
liquid-tight seal. Failure to do so could allow water to enter the housing and damage the
device. Always use Teflon tape (user-supplied) and sealant (user-supplied) on connector
threads of any mount (sold separately by Bosch or user-supplied).
If a sealant is used, make sure that it is a neutral cure type. Sealants that release acetic acid
may harm electronics.
Use drip loops on the wiring outside the housing.
Always use Teflon tape (user-supplied) and sealant (user-supplied) on connector threads of
any mount (sold separately by Bosch or user-supplied).
Warning!
ROUTING OF EXTERNAL WIRING MUST BE DONE THROUGH A PERMANENTLY EARTHED
METAL CONDUIT.
Notice!
Always use a shielded twisted pair (STP) connection cable and a shielded RJ45 network cable
connector where the camera is used outdoors or the network cable is routed outdoors.
Always use shielded cables/connectors in demanding indoor electrical environments where
the network cable is located in parallel with electrical mains supply cables, or where large
inductive loads such as motors or contactors are near the camera or its cable.
Notice!
Bosch recommends the use of surge/lightning protection devices (sourced locally) to protect
network and power cables and the camera installation site. Refer to NFPA 780, Class 1 & 2,
UL96A, or the equivalent code appropriate for your country/region, and to local building
codes. Refer also to the installation instructions of each device (surge protector where the
cable enters the building, midspan, and camera).
2021-02-19 | 0.7 |
Installation Manual
Bosch Security Systems
AUTODOME IP starlight 5100i IRSafety | en7
1.5Connection in applications
24 VAC power source: This unit is intended to operate at 24 VAC (if PoE is not available).
User-supplied wiring must be in compliance with electrical codes (Class 2 power levels).
PoE: Use only approved PoE (802.3bt) devices. Power-over-Ethernet can be connected at the
same time as a 24 VAC power supply. If auxiliary power (24 VAC) and PoE are applied
simultaneously, the camera selects PoE and stops auxiliary input.
Bosch Security Systems
Installation Manual
2021-02-19 | 0.7 |
8en | SafetyAUTODOME IP starlight 5100i IR
i
i
1.6Important notices
Notice!
This device is intended for use in public areas only.
U.S. federal law strictly prohibits surreptitious recording of oral communications.
Notice!
This is a class A product. In a domestic environment this product may cause radio
interference, in which case the user may be required to take adequate measures.
FCC & ICES Information
(U.S.A. and Canadian Models Only)
This device complies with part 15 of the FCC Rules. Operation is subject to the following
conditions:
–this device may not cause harmful interference, and
–this device must accept any interference received, including interference that may cause
undesired operation.
NOTE: This equipment has been tested and found to comply with the limits for a Class A
digital device, pursuant to Part 15 of the FCC Rules and ICES-003 of Industry Canada. These
limits are designed to provide reasonable protection against harmful interference when the
equipment is operated in a commercial environment. This equipment generates, uses, and
radiates radio frequency energy and, if not installed and used in accordance with the
instruction manual, may cause harmful interference to radio communications. Operation of
this equipment in a residential area is likely to cause harmful interference, in which case the
user will be required to correct the interference at his expense.
Intentional or unintentional modifications, not expressly approved by the party responsible for
compliance, shall not be made. Any such modifications could void the user's authority to
operate the equipment. If necessary, the user should consult the dealer or an experienced
radio/television technician for corrective action.
UL disclaimer
Underwriter Laboratories Inc. ("UL") has not tested the performance or reliability of the
security or signaling aspects of this product. UL has only tested fire, shock and/or casualty
hazards as outlined in Standard(s) for Safety for Information Technology Equipment, IEC
62368-1.
UL MAKES NO REPRESENTATIONS, WARRANTIES, OR CERTIFICATIONS WHATSOEVER
REGARDING THE PERFORMANCE OR RELIABILITY OF ANY SECURITY OR SIGNALING-RELATED
FUNCTIONS OF THIS PRODUCT.
1.7Important notices - illumination safety
2021-02-19 | 0.7 |
Installation Manual
Bosch Security Systems
AUTODOME IP starlight 5100i IRSafety | en9
i
Notice!
This product has been tested according to standard IEC62471:2006 “Photobiological safety
of lamps and lamp systems”. The product emissions meets the EXEMPT Group limit for
Cornea/Lens infrared hazard as defined by IEC 62471:2006. The product was found to meet
the EXEMPT Group exposure limits for IR LEDs.
The IEC 62471 provides the methods to determine the risk group of any lamp or any product
incorporating a lamp. The risk groups in IEC 62471 indicate the degree of risk from potential
optical radiation hazards. The risk groups were developed based upon decades of lamp use
experience and the analysis of accidental injuries related to optical radiation emission.
EXEMPT Group – no optical hazard is considered reasonably foreseeable, even for
continuous, unrestricted use. Typical examples are most frosted incandescent lamps and
fluorescent lamps used in domestic applications.
Exposure Hazard Value (EHV) is a ratio of the Exposure Level (distance, exposure time) to
Exposure Limit Value (ELV). When EHV is greater than 1, the device has exceeded the
Exposure Limit Values for a particular Risk Group. The ELV is the level where optical radiation
to the eye or skin is not expected to result in adverse biological effects.
The Hazard Distance (HD) is the distance from the source at which the Exposure Level equals
the appropriate ELV. In other words, when EHV=1 for a particular Risk Group.
Regarding the Cornea / Lens infrared hazard of this product, the Exposure Hazard Value (EHV)
at a test distance of 200mm is 2.19 based on EXEMPT Group exposure limits. The EHV based
on Risk Group 1 limits is 0.386. The HD for the Exempt Group is 297 mm.
These values have been summarized in the table below:
Hazard
Cornea / Lens
Infrared Hazard
t, durationd, distanceEHV
1000 s
Hazard Distance
1.8Customer support and service
If this unit needs service, contact the nearest Bosch Security Systems Service Center for
authorization to return and shipping instructions.
USA and Canada
Telephone: 800-289-0096, option 5
Fax: 800-366-1329
Email: repair@us.bosch.com
Telephone: 800-289-0096, option 4
Fax: 800-315-0470
Email: technical.support@us.bosch.com
Europe, Middle East, Africa, and Asia Pacific Regions
Contact your local distributor or Bosch sales office. Use this link: https://
www.boschsecurity.com/xc/en/where-to-buy/
EXEMPT Group Limits
200 mm
279 mm
2.19
Bosch Security Systems
Installation Manual
2021-02-19 | 0.7 |
10en | SafetyAUTODOME IP starlight 5100i IR
More Information
For more information, please contact the nearest Bosch Security Systems location or visit
www.boschsecurity.com.
2021-02-19 | 0.7 |
Installation Manual
Bosch Security Systems
AUTODOME IP starlight 5100i IRIntroduction | en11
2Introduction
–This equipment should be unpacked and handled with care. Check the exterior of the
packaging for visible damage. If an item appears to have been damaged in shipment,
notify the shipper immediately.
–Verify that all the parts listed in the Parts List below are included. If any items are
missing, notify your Sales or Customer Service Representative from Bosch Security
Systems.
–Do not use this product if any component appears to be damaged. Please contact Bosch
Security Systems in the event of damaged goods.
–The original packing carton (if undamaged) is the safest container in which to transport
the unit and must be used if returning the unit for service. Save it for possible future use.
--Appropriate fasteners (of corrosion-resistant stainless steel with a
diameter of 10 mm (3/8 in.)), and anchors as necessary, dependent on
the surface to which the mount is attached
2.4Establishing the connection
The unit must have a valid IP address to operate on your network and a compatible subnet
mask.
By default, DHCP is pre-set at the factory to On plus Link-Local so a DHCP server assigns an
IP address or, if no DHCP server is available, a link-local address (auto-IP) is assigned within
the range 169.254.1.0 to 169.254.254.255.
You can use the Configuration Manager to find the IP address. Download the software from
http://downloadstore.boschsecurity.com.
1.Start the Web browser.
2.Enter the IP address of the unit as the URL.
3.During initial installation, confirm any security questions that appear.
Note:
If you cannot connect, the unit may have reached its maximum number of connections.
Depending on the device and network configuration, each unit can have up to 50 web browser
connections, or up to 100 connections via BoschVideoClient or BVMS.
2.5Configuration with Project Assistant app
You can also use the Project Assistant app to complete the initial configuration of the camera.
In order to use this device with the Project Assistant app by Bosch, you must download the
app from the Bosch Download Store, from Google Play, or from the Apple Store.
You can access the app in several ways:
–Scan the QR code from the QIG.
–From www.boschsecurity.com, select Support > Apps and Tools > Online Apps - Video >
Bosch Project Assistant app. Select the appropriate operating system, and then click the
appropriate button to download and install the app.
–From Google Play Store (play.google.com), search for Bosch Project Assistant. Select the
app from the list. Click the Install button.
–From Apple Store (itunes.apple.com), search for Bosch Project Assistant. Select the app
from the list. Click the appropriate button to download and install the app.
2021-02-19 | 0.7 |
Installation Manual
Bosch Security Systems
AUTODOME IP starlight 5100i IRProduct Description | en13
3Product Description
Keep your security in focus with the many features of the AUTODOME IP starlight 5100i IR
camera. The camera is carefully tuned to deliver detailed, 4MP ultra HD images during the day
as well as full details in low-light or no-light conditions. The integrated, intelligent IR
illuminator automatically adjusts the IR intensity according to zoom factor and field of view to
ensure that the scene is illuminated uniformly.
Bosch Security Systems
Installation Manual
2021-02-19 | 0.7 |
14en | Preparing WiringAUTODOME IP starlight 5100i IR
4Preparing Wiring
4Prepare and install all wiring for 24 VAC, PoE (Cat5e or better), alarms, and audio as
necessary. For 24 VAC, follow the recommendations for maximum cable distance and
wire gage.
Maximum cable distance in meters (feet) per minimum cable diameter
The following table identifies the recommended transmission distance (maximum) in meters
(feet), based on the specified wattage, per the minimum cable diameter (in mm²), when the
cable diameter is fixed and the maximum permitted power consumption for 24 VAC is 10%.
For example, for a device of 20 W and a minimum cable diameter of 1.0 mm², the
recommended transmission distance is 42 m (141 feet) from the transformer.
ModelsWatts1.0 mm²1.5 mm²2.5 mm²4.0 mm²
Indoor
2042 m (141 ft)68 m (225 ft)109 m (358 ft)275 m (905 ft)
(ceiling)
Outdoor3028 m (94 ft)45 m (150 ft)72 m (238 ft)183 m (603 ft)
Wire Gage
Note: Metric wire sizes are standard DIN sizes, ISO6722, mm².
Wire diameter (mm²)AWG
1.018
1.516
2.514
4.012
2021-02-19 | 0.7 |
Installation Manual
Bosch Security Systems
AUTODOME IP starlight 5100i IR(Optional) Configuration Programming on a Temporary Table-top Stand | en15
!
!
!
5(Optional) Configuration Programming on a Temporary
Table-top Stand
5.1Installation Overview
Caution!
Risk of damage to camera
Please remove the tape from the top of the camera. The camera head must be free to rotate.
Caution!
ELECTRIC SHOCK HAZARD
To reduce the risk of electric shock, disconnect power to the camera and/or to the power
supply unit before moving the camera, before installing any accessories, and before mounting
the camera.
Caution!
Type and source of hazard
Take extra care lifting or moving cameras because of their weight.
5.2Configuration Programming on a Temporary Table-top Stand
The camera packaging with a PE form as a base plate allows installers to configure the
camera.
1.Remove the foam covering the head of the camera.
2.Remove the camera from the box.
3.Change the camera orientation to inverted.
4.Put the PE foam on a flat, horizontal surface.
5.Put the camera upright in the PE foam as a base plate.
6.Supply power to the camera and Connect the camera to the computer. Note that the
wiper moves one to three times across the camera window, and then returns to parked
position.
Bosch Security Systems
Installation Manual
2021-02-19 | 0.7 |
16en | (Optional) Configuration Programming on a Temporary Table-top StandAUTODOME IP starlight 5100i IR
802.3bt PoE
24VAC
50/60Hz
3
2
7.Configure the camera. Refer to the separate User Manual for details.
8.Disconnect the wires/cables from the connectors in the base of the camera.
2021-02-19 | 0.7 |
Installation Manual
Bosch Security Systems
AUTODOME IP starlight 5100i IR(Optional) Installing a microSD card | en17
6(Optional) Installing a microSD card
1.Loosen the 2 Hex screws in the back of the camera housing.
Bosch Security Systems
2.Pull up the cover of the SD card slot as illustrated in the graphic that follows.
3.Insert the card into the slot.
4.Push down the cover of the SD card slot and put the screws into their slots.
5.Tighten the screws on the cover.
Installation Manual
2021-02-19 | 0.7 |
Loading...
+ 37 hidden pages
You need points to download manuals.
1 point = 1 manual.
You can buy points or you can get point for every manual you upload.