BLODGETT
www.blodgett.com
44 Lakeside Avenue, Burlington, VT 05401 • Phone: (802) 658-6600 • Fax: (802) 864-0183
SB-G-6-6K
SHORT FORM SPECIFICATIONS
Provide Blodgett model SB-6G-6-6K (6 pan) or SB-10G-6-6K (10 pan) convection steamer with 60” wide, 250,000 BTU gas steam boiler base and two 6 gallon direct steam kettles.
The SB-6G-6-6K is comprised of two 3 pan compartments. The SB-10G-6-6k is comprised of two 5 pan compartments. Steamer shall be constructed of #4 satin finish 304 stainless steel
with a one piece welded 316 stainless steel cooking chamber with coved corners. The door shall have a removable inner liner of stainless steel with full perimeter gasket seal, an outer
liner of one-piece all welded stainless steel, and a positive lock and seal mechanism with spring release. Each compartment shall have removable stainless steel pan supports. A stainless steel drip trough integrally connected to collect and drain condensate with the doors open. The control housing shall be constructed of stainless steel with a full access removable
panel. The controls shall include a ready indicator light, cooking indicator light, and a 60 minute electric timer with audible alarm that signals the end of the cook cycle. Steam flow to the
compartment shall be cut off when the door is opened during the cook cycle and shall be reactivated when the door is closed.
The kettles shall have a double wall interior to form a steam jacket around the lower 2/3 of the kettle. The bottom of the kettle shall be of hemispherical design for superior heat circulation. Steam control valve mounted in leg. The tubular stainless steel mounting legs shall have the steam supply and condensate return pipes completely concealed within the leg memebers. The sealed stainless steel tilt mechanism bearings shall permit the kettle to tilt forward 90° for complete emptying. A removeable operating handle with heat proof knob shall be
mounted on the left or right. Unit shall have a single support leg with nylon insert. Construction shall be all welded satin finish 304 stainless steel with a 316 stainless steel liner.
The boiler base shall have full perimeter painted angle iron frame, reinforced boiler mountings, gas fired boiler with controls, stainless steel exterior, hinged doors and 6” (152 mm) stainless steel legs with adjustable bullet feet on the front and flanged feet on the rear. Boiler controls shall include an on/off power switch with indicator light, automatic water level, pressure
gauge, water gauge glass, pressure control with pressure safety control, safety relief valve, cathodic protector CSD-1 secondary low water cut off.
Boiler and kettle shall be ASME code stamped and National Board registered. Provide options and accessories as indicated.
WATER SUPPLY:
Water quality is a major factor affecting the performance of your steamer. If you are unsure of
water quality, consult a local water treatment specialist and have the water analyzed. Your water
supply must be within these general guidelines:
Total dissolved solids: Less than 60 PPM Total alkalinity: Less than 20 PPM
Silica: Less than 13 PPM Chlorine: Less than 1.5 PPM
pH Factor: 7.0 - 8.5
Water which fails to meet these standards should be treated by installation of a water conditioner.
Failure or malfunction of this steamer due to poor water quality is not covered under warranty.
Appliance is to be installed with backflow protection in accordance with Federal, State or Local
codes.
MINIMUM INPUT:
Standard 250,000 BTU/hr
Optional 300,000 BTU/hr
Minimum Inlet Pressure:
Natural 7.0" W.C. static to unit
Propane 11.0" W.C. static to unit
SHIPPING INFORMATION:
Approx. Weight:
SB-6G-6-6k 1010 lbs. (458 kg)
SB-10G-6-6k 1050 lbs. (476 kg)
Printed in U.S.A. NOTE: FOR COMMERCIAL USE ONLY
NOTE: The company reserves the right to make substitutions of components without prior notice.
NOTE: SPLASH GUARD NOT SHOWN ON FRONT VIEW
REAR FLANGED
FOOT DETAIL
7/16" [11mm] HOLES
ON 2.5 [63] B.C.
2 EQUALLY SPACED
Ø
DIMENSIONS ARE IN INCHES [MM]
S
ELECTRICAL CONNECTION: ½”conduit connection
to controls. Rating to be specified on data plate.
GAS CONNECTION: 3/4” IPS supply line required.
STEAM TAKE-OFF CONNECTION: 3/4” IPS
optional to operate adjacent equipment.
HOT AND COLD WATER: 3/8” O.D. tubing at
25-50 PSI (170-345 kPa).
DRAIN: 2” IPS piped to open
floor drain. No solid connection.
SINK DRAIN: 1-1/8” O.D. tubing
24.25
[616]
59.5 [1511] SB-6G-6-6K
72.5 [1842] SB-10G-6-6K
24 [610]
32 [813]
6 [152]
13.5 [343]
8.75 [222]
6.25 [159]
5.75 [146]
66.13 [1680]
Ø12 [305]
S
16.75 [425]
33 [838]
9.5 [241]
3 [76]
13.5 [343]
17.75 [451]
S