BLAUBERG Company is happy to offer your attention a new
generation product, the BLAUBERG Quatro fan.
The solid team of high-qualified professionals with many years
of working experience, technological innovations in design and
production, high-quality components and materials from the top
worldwide producers have become the precondition for the
best fan in its class.
INTRODUCTION
The present service instruction contains a technical description,
technical data sheets, operation and mounting guidelines, safety
precautions and warnings for safe and correct operation of the fan
BLAUBERG Quatro.
USE
The BLAUBERG Quatro fan is designed for exhaust ventilation of
residential and public premises heated during winter season.
The fan is designed for wall or ceiling mounting, fig. 3-5.
The fan is equipped with a back valve to prevent air back drafting during
the fan standby.
COMPLETE SET
fan - 1 item;
screws and dowels - 4 items;
plastic screwdriver (for the models with timer) - 1 item;
service instruction;
packing box.
The fan design is regularly improved, so some models can slightly differ
from those ones described in this service instruction.
18
Table 1
Switch (S) - built-in pull cord switch.
Timer (T) - turn-off time range from 2 to 30 min.
Humidity sensor (H) - humidity level range from 60% to 90%.
The fan does not cause interference with radio-, TV- or video- equipment.
Service life is not less than 5 years.
19
BASIC CHARACTERISTICS
The fan designations, delivery set options, parameters, outer view,
overall and connecting dimensions are shown in tables 1, 2, 3
and in fig. 1 and 2.
Type
Max. air flow
3
[m /h]
Power
[W]
Noise level,
3 m [dBA]
RPM
[min-1]
Quatro 100
Quatro 125
Quatro 150
14
2300
88
33
16
2400167 34
24
2400
265
37
Quatro ___
Quatro ___ S
Quatro ___ T
Quatro ___ ST
Quatro ___ H
Quatro ___ SH
Switch
Timer
Humidity
sensor
Table 2
Type
20
Fig. 1
1 - cover; 2 - timer;
3 - casing; 4 - motor;
5 - impeller; 6 - back valve.
123456
a
171
201
236
a1
151
178
207
d
100
125
150
e
32
35
38
Dimensions [mm]
0,56
0,73
0,9
Type
Quatro 100
Quatro 125
Quatro 150
b
108
113
165
c
128
136
157
Table 3
Weight
[kg]
Fig. 2
21
OPERATION RULES
The fan is rated for connection to 220...240 V / 50 Hz power mains
and is rated for continuous operation always connected to power mains.
The air motion direction in the system must match the pointer on the
fan casing.
The fan is rated for operation at ambient temperature from +1 °C up to
+45 °C.
The fan does not require grounding.
SAFETY RULES
All operations related to the fan electrical connections, servicing and
repair works are allowed only after the fan disconnection from power
mains.
All mounting and servicing operations are allowed for duly qualified
electricians with valid electrical work permit for electric operations
at the units up to 1000 V after careful study of the present user's manual.
The single-phase power grid must comply with the acting local electrical
norms and standards.
The fixed electrical wiring must be equipped with an automatic switch
that is used for connection of the fan to power mains with gap on all
poles at least 3 mm.
Make sure the impeller and the casing are not damaged before starting
installation.
The casing internals must be free of any foreign objects which can
damage the impeller blades.
Misuse of the product or any unauthorized modification are not allowed.