BLAUBERG Ventilatoren Lux 100, Lux 125, Lux 150, Glory 100, Glory 125 Service Instructions Manual

...
0 (0)
EN
Lux
Glory
Service Instructions
BLAUBERG Company is happy to offer your attention new generation products, the BLAUBERG Lux and Glory fans. The solid team of high-qualified professionals with many years of working experience, technological innovations in design and production, high-quality components and materials from the top worldwide producers have become the precondition for the best fans in their class.
INTRODUCTION
The present service instruction contains a technical description, technical data sheets, operation and mounting guidelines, safety precautions and warnings for safe and correct operation of the fans BLAUBERG Lux and Glory.
USE
The fan is designed for exhaust ventilation of residential and public premises heated during winter season. The fan is designed for wall mounting, fig. 3-5.
COMPLETE SET
- fan - 1 item;
- screws and dowels - 4 items;
- plastic screwdriver (for the models with timer) - 1 item;
- service instruction;
- packing box.
The fan design is regularly improved, so some models can slightly differ from those ones described in this service instruction.
18
Table 1
The fan does not cause interference with radio-, TV- or video- equipment. Service life is not less than 5 years.
19
BASIC CHARACTERISTICS
The fan designations, delivery set options, parameters, outer view, overall and connecting dimensions are shown in tables 1, 2, 3 and in fig. 1 and 2. The model without timer is shown in fig. 1.
Type
Max. air flow
3
[m /h]
Power [W]
Noise level,
3 m [dBA]
-1
RPM [min ]
Lux/Glory 100
14
2300
89
33
Lux/Glory 125
16
2400164 34
Lux/Glory 150
24
2400
258
37
Fig. 1
1 - front panel (for Lux - polished stainless steel, for Glory - frosted glass); 2 - cover, 3 - LED light; 4 - decorative fitting piece; 5 - casing; 6 - electric motor, 7 - impeller, 8 - cover cap (only for Lux/Glory 150).
8
7
6
5
4
3
2
1
Dimensions [mm]
Table 3
Type
Lux 100
Weight
[kg]
20
Fig. 2
Lux 125
Lux 150
Glory 100
Glory 125
Glory 150
183
205
233
120
140
165
145
146
169
100
125
150
58
58
58
Timer (T) - turn-off time range from 2 to 30 min; Humidity sensor (H) - humidity level range from 60% to 90%.
Type
Lux/ Glory 100
Lux/ Glory 100 T
Lux/ Glory 100 H
Timer
Humidity
sensor
Table 2
Lux/ Glory 125
Lux/ Glory 150
Lux 100 T/H
Glory 100 T/H
183
120
153,6
98
67
a
181
b
120
c
148
d
100
98
e
56
65
0,65
0,7
0,85
0,85
0,9
1,15
231 165
161
150 56
1,05
1,65
140
120
154
151,6
125
56
183
204
21
OPERATION RULES
The fan is rated for connection to 220...240 V / 50 Hz power mains and is designed for continuous operation always connected to power mains.
The air motion direction in the system must match the pointer on the fan casing.
The fan is rated for operation at ambient temperature from +1 °C up to +45 °C.
The fan does not require grounding.
SAFETY RULES
All operations related to the fan electrical connections, servicing and repair works are allowed only after the fan disconnection from power mains. All mounting and servicing operations are allowed for duly qualified electricians with valid electrical work permit for electric operations at the units up to 1000 V after careful study of the present user's manual. The single-phase power grid must comply with the acting local electrical norms and standards. The fixed electrical wiring must be equipped with an automatic switch that is used for connection of the fan to power mains with gap on all poles at least 3 mm. Make sure the impeller and the casing are not damaged before starting installation. The casing internals must be free of any foreign objects which can damage the impeller blades. Misuse of the product or any unauthorized modification are not allowed.