BLAUBERG Ventilatoren Axis-Q 200 2E, Axis-Q 250 2E, Axis-Q 250 2D, Axis-Q 250 4E, Axis-Q 250 4D Operation Manual

...
0 (0)
OPERATION MANUAL
AXIAL FANS
Axis / Tubo
EN
AXIS-QRA AXIS-QA G
AXIS-Q TUBO-F
AXIS-QA
AXIS-QR AXIS-F
2
www.blaubergventilatoren.de
Axis / Tubo
3 Introduction
3 General
3 Safety rules
3 Transport and storage requirements
3 Manufacturer's warranty
4 Fan design
4 Delivery set
4 Modications and options
5 Technical data
10 Mounting and operation guidelines
11 Mounting sequence
11 Installation and connection to power mains
13 Maintenance
14 Warranty card
CONTENT
www.blaubergventilatoren.de
3
Axis / Tubo
BLAUBERG Company is happy to oer your attention the new high-quality axial fans Blauberg Axis and Blauberg Tubo. The solid team of high-qualied professionals with many years of working experience, technological innovations in design and production, high-quality components and materials from the top worldwide producers have become the precondition for the best fan in its class.
INTRODUCTION
The present operation manual contains technical description, technical data sheets, operation and mounting guidelines, safety precautions and warnings for safe and correct operation of the fan.
GENERAL
The axial fans Axis, Tubo are not a ready for use product. It is a component unit designed for integration into air conditioning and ventilation systems.
The fans Axis-Q, Axis-QR, Axis-QA, Axis-QRA are designed for direct air exhaust. The models Axis-F are designed for connection to Ø 205 mm up to 645 mm air ducts and the models Tubo-M, Tubo-MZ are designed for connection to Ø 160 mm up to 315 mm air ducts.
The fan has IEC Protection Class I and must be grounded.
The fans are allowed for operation only after nal mounting, that includes installation of protecting devices in compliance with DIN EN ISO 13875 (DIN EN ISO 12100) as well as other construction safety equipment.
The fan design is regularly improved, so some models can slightly dier from those ones described in this service instruction.
SAFETY RULES
The fan complies with the requirements according to the EU norms and directives, to the relevant EU-Low Voltage Equipment Directives, EU­Directives on Electromagnetic Compatibility.
All operations related to the fan electrical connections, servicing and repair works are allowed only after the fan disconnection from power mains.
All mounting and servicing operations are allowed for duly qualied electricians with valid electrical work permit for electric operations at the units up to 1000 V after careful study of the present user's manual.
Please follow the safety regulations and working instructions (DIN EN 50 110, IEC 364).
Make sure the impeller and the casing are not damaged before connecting the fan to power mains. The casing internals must be free of any foreign objects which can damage the impeller blades.
Disconnect the fan from power mains prior to any operations related to the fan servicing and repair works.
Take measures to prevent contact with the fan to avoid physical damages during the fan step and start-up.
Misuse of the product or any unauthorized modication are not allowed.
The fan is designed for connection to ac single-phase or ac three-phase power mains, see „Technical Data“. The fan is rated for permanent operation during non-stop power supply.
Take steps to prevent ingress of smoke, carbon monoxide and other combustion products into the room through open chimney ues or other re-protection devices. Sucient air supply must be provided for proper combustion and exhaust of gases through the chimney of fuel burning
equipment to prevent back drafting. The maximum permitted pressure dierence per living units is 4 Pa.
The transported air must not contain any dust or other solid impurities, sticky substances or brous materials.
The fan is not designed for use in an inammable and explosive medium.
The transported medium must not have an aggressive eect on steel at the temperature stated on pages 5–8 of the section „Technical data”.
Do not close or block the fan intake or exhaust vent not to disturb the normal air passage. Do not sit on the fan and do not put objects on the fan.
Follow the manual guidelines to ensure trouble-free operation and long service life of the product.
STORAGE AND TRANSPORTATION RULES
Store the delivered product in the manufacturer's original packing box in a dry ventilated premise with the ambient temperature from +5°C up to +40°C and relative humidity less than 80 % at the temperature +25°C .
Store the fan in an environment with minimized risk of mechanical damages, temperature and humidity uctuations. Store the fan inside a room or under a shelter.
Transport of the product is allowed by any vehicle in the manufacturer's original packing box. Use hoist machinery for handling and transportation to prevent possible mechanical damages of the product. Full the requirements for transportation of the specied cargo type during cargo-handling operations.
Do not expose the product to extremely low or high temperatures.
MANUFACTURER'S WARRANTY
The fan complies with the requirements according to the EU norms and directives, to the relevant EU-Low Voltage Equipment Directives, EU­Directives on Electromagnetic Compatibility.
We hereby declare that the following product complies with the essential protection requirements of Electromagnetic Council Directive 2004/108/ EC, 89/336/EEC and Low Voltage Directive 2006/95/EC, 73/23/EEC and CE-marking Directive 93/68/EEC on the approximation of the laws of the Member States relating to electromagnetic compatibility. This certicate is issued following test carried out on samples of the product referred to above. Assessment of compliance of the product with the requirements relating to electromagnetic compatibility was based on the following standards.
The manufacturer hereby warrants normal operation of the fan over the period of 2 years from the retail sale date provided observance of the installation and operation regulations.
In case of failure due to faulty equipment during the warranty period the consumer has the right to exchange it.
If case of no conrmation of the sale date, the warranty term shall be calculated from the manufacturing date.
The replacement is oered by the Seller.
The MANUFACTURER shall not be liable for any damage resulting from any misuse of or gross mechanic interference with the fan.
Please follow the operation guidelines always.
WARNING
Do not dispose in domestic waste.
The unit contains in part material that can be recycled and in part substances that should not end up as domestic waste.
Dispose of the unit once it has reached the end of its working life according to the regulations valid where you are.
ATTENTION
The product is not allowed for use by children and persons with reduced physical, mental or sensory capacities, without proper practical experience or expertise, unless they are controlled or instructed on the product operation by the person(s) responsible for their safety. Supervise the children and do not let them play with the product.
!
4
www.blaubergventilatoren.de
Axis / Tubo
DELIVERY SET
DELIVERY SET
DELIVERY SET
fan – 1 item; operation manual.
fan – 1 item; screws and dowels - 4 items;
mounting brackets – 2 items;operation manual.
FAN DESIGN AXISQ / AXISQR / AXISQA / AXISQRA
FAN DESIGN AXISF
FAN DESIGN TUBOM / TUBOMZ
MODIFICATIONS AND OPTIONS
MODIFICATIONS AND OPTIONS
ange
impeller
cover
casing
casing
terminal
block
impeller
mounting
bracket
TUBO-M
Fan made of polymer coated steel
TUBO-MZ
Fan made of galvanized steel
AXIS-Q
Fan with a square mounting plate
AXIS-QR
Fan with a round mounting plate
Fig. 1
Fig. 2
Fig. 3
fan – 1 item; operation manual.
ange
impeller
casing
terminal block
www.blaubergventilatoren.de
5
Axis / Tubo
AXISQ / AXISQR / AXISF
TECHNICAL DATA
Axis-Q / Axis-QR / Axis-F
200 2E
Axis-Q / Axis-QR / Axis-F
250 2E
Axis-Q / Axis-QR / Axis-F
250 4E
Axis-Q / Axis-QR / Axis-F
300 2E
Voltage 1~ 220-240 1~ 220-240 1~ 220-240 1~ 220-240
Frequency [Hz] 50 60
50 60 50 60 50 60
Power [W]
55 61 80 91 50 56 145 178
Current [A]
0.26 0.28 0.4 0.42 0.22 0.24 0.66 0.79
Max. air ow [m3/h]
860 875 1050 1150 800 865 2230 2280
RPM [min-1]
2300 2550 2400 2990 1380 1730 2300 2410
Noise level, 3 m [dBA]
50 51 60 61 55 56 60 61
Max. transported air temperature [°C]
-30 +60 -30 +50 -30 +60 -30 +50 -30 +60 -30 +50 -30 +60 -30 +50
Ingress Protection Rating
IP24
Axis-F IPX4
IP24
Axis-F IPX4
IP24
Axis-F IPX4
IP24
Axis-F IPX4
Axis-Q / Axis-QR / Axis-F
300 4E
Axis-Q / Axis-QR / Axis-F
350 4E
Axis-Q / Axis-QR / Axis-F
400 4E
Axis-Q / Axis-QR / Axis-F
450 4E
Voltage
1~ 220-240 1~ 220-240 1~ 220-240 1~ 220-240
Frequency [Hz]
50 60 50 60 50 60 50 60
Power [W]
75 92 140 147 180 240 250 325
Current [A]
0.35 0.4 0.65 0.66 0.82 1.08 1.2 1.46
Max. air ow [m3/h]
1340 1475 2500 2650 3580 3890 4680 4790
RPM [min-1]
1350 1405 1380 1700 1380 1655 1350 1600
Noise level, 3 m [dBA]
58 59 62 63 63 64 64 65
Max. transported air temperature [°C]
-30 +60 -30 +50 -30 +60 -30 +50 -30 +60 -30 +50 -30 +60 -30 +50
Ingress Protection Rating
IP24
Axis-F IPX4
IP24
Axis-F IPX4
IP24
Axis-F IPX4
IP24
Axis-F IPX4
Axis-Q / Axis-QR / Axis-F
500 4E
Axis-Q / Axis-QR / Axis-F
550 4E
Axis-Q / Axis-QR / Axis-F
630 4E
Axis-Q / Axis-QR / Axis-F
630 6E
Voltage
1~ 220-240 1~ 220-240 1~ 220-240 1~ 220-240
Frequency [Hz]
50 60 50 60 50 60 50 60
Power [W]
420 455 550 654 750 979 540 610
Current [A]
1.95 2.05 2.55 2.88 3.5 4.26 2.4 2.74
Max. air ow [m3/h]
7060 7130 8800 8970 11900 12100 10900 10990
RPM [min-1]
1300 1630 1300 1580 1360 1625 850 1075
Noise level, 3 m [dBA]
69 69 70 71 75 76 72 72
Max. transported air temperature [°C]
-30 +60 -30 +50 -30 +60 -30 +50 -30 +60 -30 +50 -30 +60 -30 +50
Ingress Protection Rating
IP24
Axis-F IPX4
IP24
Axis-F IPX4
IP24
Axis-F IPX4
IP24
Axis-F IPX4