B&K Precision 2100C User Manual

Data Sheet
Analog Oscilloscopes With Probes
2100C Series
B&K Precision's 212x Series are dual trace oscilloscopes that offers high performance at a low price. Most competitor's entry level oscilloscopes have a 20 MHz bandwidth, while B&K Precision's 212x Series have a bandwidth of 30-60 MHz. These oscilloscopes are built by and backed by B&K Precision, a company that has been selling reliable, durable, value priced test instruments
Common Features & Benefits
Dual or single trace operation
5 mV/div sensitivity
Calibrated 23-step time base with X10
magnifier
Video sync trigger
Alternate/chop sweep
Sum and difference capability
Additional Features
Built-in component tester (2125C only)
Built-in 50 MHz frequency counter
(2121C only)
Delayed time base
Main, Mix, Delay, X-Y sweep modes
for over 60 years.
Specifications 2120C 2121C 2125C 2160C
Bandwidth 30 MHz 30 MHz 30 MHz 60 MHz
Sweep Time 0.1 µs/div to 2 s/div 20 ns/div to 5 s/div
Component Tester
- -
Counter - - -
Technical data subject to change © B&K Precision Corp. 2014
www.bkprecision.com
Analog Oscilloscopes
100C Series
2
Specifications 2120C & 2121C
VERTICAL AMPLIFIERS (CH 1 and CH 2)
ensitivity
S
ttenuator
A
ccuracy
A
Input Resistance 1 M ±2% nput Capacitance
I
Frequency Response 5 mV to 5 V/div: DC to 30 MHz (-3dB). X5: DC to 10 MHz (-3dB)
ise Time
R
Operating Modes CH 1: CH 1, single trace
CH 2 CH 2, single trace
LT
A
CHOP dual trace, chopped
ADD agebraic sum of CH 1 + CH 2
olarity Reversal
P
Maximum Input Voltage 400 V (DC + AC peak)
SWEEP SYSTEM
Sweep Speed
Accuracy ±3%
Sweep Magnification
RIGGERING
T
Triggering Modes AUTO (free run) or NORM, TV-V, TV-H
rigger Source
T
Max External Trigger Voltage 300 V (DC + AC peak)
Trigger Coupling AC 30 Hz to 30 MHz
TV H Used for triggering from horizontal sync pulses TV V Used for triggering from vertical sync pulses
RIGGER SENSITIVITY
T
HORIZONTAL AMPLIFIER (Input through channel 2 input)
CRT
COUNTER (2121C)
GENERAL
uto
A
orm
N
TV V Bandwidth: 20 Hz-1 kHz, Internal: .5 div, External: 100 mV TV H Bandwidth:1 kHz-100 kHz, Internal: .5 div, External: 100 mV
X-Y Mode Switch selectable using X-Y switch. CH 1: X axis, CH 2: Y axis
Sensitivity Same as vertical channel 1
Input Impedance Same as vertical channel 1
Frequency Response DC to 1 MHz typical (-3 dB)
X-Y Phase Difference Approximately 3˚ at 50 kHz
Maximum Input Voltage Same as vertical channel 1
Type Rectangular with internal graticule
Display Area 8 x 10 div (1 div = 1 cm)
Accelerating Voltage
Phosphor P31
Trace Rotation Electrical, front panel adjustable
Calibrating Voltage 1 kHz (±10%) positive square wave, 2 V p-p (±3%)
Display 5 digits, 0.36” red LED, display at “Hz” or “kHz” auto range
Display Resolution Auto select from 0.001 Hz to 1 kHz depending on the frequency
Max. Counter Range 0.1 Hz to 50 MHz
Accuracy +0.01% + 1 digit or 1/99999 + 1 digit
Time Base 18,432 MHz + 10ppm (23 ºC ±5 ºC)
Temperature
Power Requirements 100/120/220/240 VAC ±10%, 50/60 Hz, approximately 40 W.
Dimensions (WxHxD) 7 x 14.5 x 17.25" (180 x 370 x 440 mm)
Weight 17.2 lbs (7.8 kg)
mV/div to 5 V/div, 1 mV/div to 1 V/div at X5
5
10 steps in 1-2-5 sequence. Vernier control provides
ull adjustment between steps
f
3%, ±5% at X5
±
5 pF ±10 pF
2
2 ns (Overshoot 5%)
1
ual trace, alternating
d
H 2 only
C
0.1 µs/div to 2 s/div in 1-2-5 sequence, 23 steps,
ernier control provides fully adjustable sweep time between steps.
V
10x
H 1, CH 2, ALT, EXT, LINE
C
andwidth:100 Hz-30 MHz, Internal: 1.5 div, External: 100 mV
B
andwidth: DC to 30 MHz, Internal: 1.5 div, External: 100 mV
B
2 kV
Within specified accuracy: 50˚ to 95˚F (10˚ to 35˚C), 85% RH
Full operation: 32˚ to 104˚F (0˚ to 40˚C), 85% RH
storage: -4˚ to 158˚F ( -20˚ to +70˚C
One Year Warranty
Supplied Accessories
Optional Accessories
Instruction manual, two PR-33A x1/x10 probes or equivalent,
PR-32A demodulator probe, PR-37A x1/x10/REF. probe, PR-100A x100 probe, PR-55 high voltage x1000 probe,
AC power cord and spare fuse
LC-210A carrying case
Specifications 2125C & 2160C
VERTICAL AMPLIFIERS (CH 1 and CH 2)
Sensitivity 5 mV/div to 5 V/div, 1 mV/div to 1 V/div at x5
ttenuator
A
Accuracy ±3%, ±5% at x5
Input Resistance 1 M +2% nput Capacitance
I
requency Response
F
Rise Time 12ns (Overshoot 5%)
Operating Modes CH 1: CH 1, single trace
H 2
C
LT
A
CHOP dual trace, chopped
DD
A
olarity Reversal
P
Max. Input Voltage 400 V (DC to AC peak)
WEEP SYSTEM
S
Operating Modes
Main Sweep SpeeD
ccuracy
A
Sweep Magnification 10X, ±5%
elayed Sweep Speed
D
oldoff
H
elay Time Position
D
TRIGGERING
Triggering Modes AUTO (free run) or NORM, TV-V, TV-H
rigger Source Maximum External CH 1, CH 2, ALT, EXT, LINE
T
Trigger Voltage 300 V (DC + AC peak)
Trigger Coupling
TRIGGER SENSITIVITY
Auto Bandwidth: 100Hz - 40MHz, Internal: 1.5 div, External: 0.1Vp-p
Norm Bandwidth: 100Hz - 40MHz, Internal: 1.5 div. External: 0.1Vp-p
TV-V Bandwidth: DC -1kHz, Internal: 0.5 div, External: 0.05Vp-p
TV-H 1 kHz - 100kHz, Internal: 0.5 div, External: 0.05Vp-p
HORIZONTAL AMPLIFIER (Input through channel 1 input)
X-Y Mode Switch selectable using X-Y switch. CH 1: X axis, CH 2: Y axis Sensitivity Same as vertical channel 2
Accuracy Y-Axis: ±3%. X-Axis: ±6%
Input Impedance ame as vertical channel 2
Frequency Response DC to 1MHz typical (-3 dB), to 6 div horizontal deflection
X-Y Phase Difference 3˚ or less at 50 kHz
Max. Input Voltage Same as vertical channel 2
CRT
Type Rectangular with internal graticule
Display Area 8 x 10 div (1 div = 1 cm)
Accelerating Voltage 2 kV, 12 kV (2160C)
Phosphor P31
Trace Rotation Electrical, front panel adjustable
COMPONENT TESTER
Components Tested Resistors, Capacitors, Inductors, and Semiconductors
Test Voltage 6 V rms maximum (open)
Test Current 11 mA maximim (shorted)
Test Frequency Line frequency (60 Hz in USA)
Calibrating Voltage 1 kHz (±10%) positive square wave, 0.2 V p-p (±2%)
GENERAL
Temperature
Power Requirements
Dimensions (WxHxD) 7 x 14 .5 x 14.25" (180 x 370 x 440 mm)
Weight 17.2 lbs (7.8 kg)
10 steps in 1-2-5 sequence. Vernier control provides
mV to 5 V/div: DC to 30 MHz (-3dB), X5: DC to 10 MHz (-3dB)
5
X5 MAG: DC to 15 MHz (-3 dB). Model 2160C
Main, mix (both main sweep and delay sweep displayed),
23 steps Vernier control provides fully adjustable sweep time between steps
ontinuously variable for Main sweep up to 10 times normal
C
ontinuously variable to control percentage of display that is
C
AC 30 Hz to 30 MHz, TV H used for triggering from horizontal sync pulses,
Within specified accuracy:
Full operation: 32˚ to 104˚ F (0˚ to 40˚C), 85% RH
ull adjustment between steps
f
5 pF ±10 pF
2
C to 60 MHz (-3 dB). Model 2160C
D
H 2, single trace
C
ual trace, alternating
d
gebraic sum of CH 1 + CH 2
a
H 2 only
C
or Delay (only delay sweep displayed), X-Y
0.1 µs/div to 2.0 s/div in 1-2-5 sequence,
3%
±
.1 ms/div to 0.1s/div in 1-2-5 sequence, 23 steps
0
evoted to main and delay sweep
d
TV V Used for triggering from vertical sync pulses
50˚ to 95˚F (10˚ to 35˚C), 85% RH
Storage: -4˚ to 158˚ F (-20˚ to +70˚C)
100/120/220/240 VAC ±10%, 50/60 Hz, Approximately 40 W
One Year Warranty
Supplied Accessories
Optional Accessories
Instruction manual, two PR-33A x1/x10 probes or equivalent,
PR-32A demodulator probe, PR-37A x1/x10/REF. probe, PR-100A x100 probe,
PR-55 high voltage x1000 probe, LC-210A carrying case
AC power cord and spare Fuse
2 www.bkprecision.com
v012214
Loading...