B&K Precision 1900, 1901, 1902 Datasheet

Page 1
Data Sheet
High Power Switching DC Power Supplies
Models 1900, 1901 & 1902
Full-Featured DC Power Supplies to Meet Your High Power Needs
B&K Precision models 1900, 1901, and 1902 are laboratory grade switching DC power supplies with high current output in a small, lightweight form factor. The 1900 Series provide various configurations of high output voltage or high output current and feature rotary encoder control knobs, which make setting voltage and current fast and precise. Its dual action push button allows the user to set both coarse and
its preset and remote control modes. Save up to three different presets of voltage and current values for quick recall. The analog remote control function allows the output power, voltage, and current to be adjusted without touching the front panel of the power supply. A remote sensing terminal (model 1900 only) is also available to compensate for voltage drop across load leads.
fine, voltage and current levels.
These features make the 1900, 1901, and 1902 In addition to constant voltage (CV) and constant current (CC) modes, the high efficiency DC power supply offers a unique solution with
suitable for a wide range of applications requiring
high current including production testing,
telecommunications, R&D, service, and
university labs.
Outputs/Model 1900 1901 1902
Variable Output Voltage 1 - 16 V 1 - 32 V 1 - 60 V
Variable Output Current 0 - 60 A 0 - 30 A 0 - 15 A
Features and Benefits
Automatic CV (Constant Voltage)/CC
(Constant Current) crossover operation
Up to 60 A output current
Lightweight and compact
Rotary encoder control for precise voltage and
current setting
Save up to 3 user-defined voltage and current
presets for quick recall
Analog remote control function
Remote sensing terminal (model 1900 only)
Overvoltage, overtemperature, and overload
protection
Flexible operating modes: Front panel
(normal), Preset, or Remote Control
Front panel 5 amp auxiliary output
Technical data subject to change © B&K Precision Corp. 2014
ww w .bk pre c i sion.com
Page 2
High Power Switching DC Power Supplies
odels 1900, 1901 & 1902
M
Work Easier
Fully Protected
Have peace of mind knowing that these power supplies come with built-in OVP (overvoltage protection), OTP (overtemperature protection), and OLP (overload protection) circuitry. These protections help prevent serious damage to equipment in case of power supply failure.
Custom Presets
Quickly use common voltage and current settings with a flip of the Recall preset switch. Up to three different presets can be set and recalled.
Flexibility & PerformanceDesigned to Make Your
Rotary encoder knobs for quick and precise setting of voltage and current
Bright, dual LED displays
LED indicators for constant voltage and constant current modes
Analog Remote Control Capability
Use the included connector to wire up to an external variable DC voltage source or variable resistor to remotely control the power supply's output voltage and current or to turn the output on/off.
Remote Sense (Model 1900 only)
Improve regulation of the power supply’s output voltage at the load by using the remote sense terminals to compensate for voltage drop across load leads.
Rear Panel
Main output terminal
Recall preset switch
Analog remote control terminal
Rear Control Indicator
Mode selection switch
Auxiliary output terminal
Cooling fan
Page 3
High Power Switching DC Power Supplies
odels 1900, 1901 & 1902
M
Specifications
Mode ls 1900 1901 19 0 2
Outp u t
Variable Output Voltage 1 – 16 V 1 – 32 V 1 – 60 V
Variable Output Current 0 – 60 A 0 – 30 A 0 – 15 A
Auxiliary Output Current 5 A
Vo lta g e Reg u l a t i on
Load (0-100% Load) 50 mV
Line (90-132 VAC, 170-264 VAC Variation) 20 mV
Cur r e n t R e g ul ation
Load (10-90% Rated Voltage) 200 mA 150 mA 100 mA
Line (90-132 VAC, 170-264 VAC Variation) 50 mA
Rip p l e & Nois e
Ripple & Noise Voltage (rms) 5 mV
Ripple & Noise Voltage (peak-peak) 50 mV 50 mV 100 mV
Current Ripple & Noise (rms) 100 mA
Mete r T y p e & Accurac y
Voltage Meter 3-Digit LED Display ± 0.2% + 3 counts
Current Meter 3-Digit LED Display ± 0.2% + 3 counts
Oth e r
AC Input 100 - 120 VAC 60 Hz, 220 - 240 VAC 50 Hz*
Full Load Input Current
Efficiency
Switching Frequency 65 – 85 kHz 75 – 95 kHz 65 – 85 kHz
Tracking Overvoltage Protections
Transient Response Time (50-100% Load) 1.5 ms
Power Factor Correction > 0.95 at optimal load
Cooling Method Thermostatically controlled fan from zero to full speed
Protections Overload, Short Circuit by Constant Current, Overvoltage, Overtemperature
Special Features 3 User-Defined Voltage and Current Presets, Analog Remote Control, Remote Sense (model 1900 only)
Operating Temperature 32 °F to 104 °F (0 °C to 40 °C), 80% R.H.
Storage Temperature 5 ºF to 158 ºF (-15 ºC to 70 ºC), 85% R.H.
Dimensions (W x H x D) 7.9” x 3.5” x 10.8” (200 x 90 x 275 mm)
Weight 7 lbs (3.2 kg)
Included Accessories Power cord, instruction manual, remote control connector
Note: All specifications apply to the unit after a temperature stabilization time of 15 minutes over an ambient temperature range of 23 °C ± 5 °C.
*Special order instructions: For 230 V version, request model 1900-220 V, 1901-220 V, or 1902-220 V.
9.4 A (110 VAC)
4.7 A (230 VAC)
84% (110 VAC) 85% (230 VAC)
O/P 1-5 V: set voltage +2 V
O/P 5-16 V: set voltage +3 V
50 mA (110 VAC) 40 mA (230 VAC)
9.0 A (110 VAC)
4.5 A (230 VAC)
87% (110 VAC) 86% (230 VAC)
O/P 1-5 V: set voltage +2 V
O/P 5-20 V: set voltage +3 V
O/P 20-32 V: set voltage +4 V
O/P 5-20 V: set voltage +3 V
O/P 20-60 V: set voltage +4 V
15 mA
9.3 A (110 VAC)
4.5 A (230 VAC)
87% (110 VAC) 88% (230 VAC)
O/P 1-5 V: set voltage +2 V
Two-Year Warranty
3 ww w.b k pr ec isio n.c om
v040914