B&K Precision 1747 User Manual

Model 1747
Dual Range DC Power Supply
INSTRUCTION MANUAL

1 Safety Summary

The following safety precautions apply to both operating and maintenance personnel and must be observed during all phases of operation, service, and repair of this instrument. Before applying power, follow the installation instructions and become familiar with the operating instructions for this instrument.
GROUND THE INSTRUMENT
To minimize shock hazard, the instrument chassis and cabinet must be connected to an electrical ground. This instrument is grounded through the ground conductor of the supplied, three-conductor ac power cable. The power cable must be plugged into an approved three-conductor electrical outlet. Do not alter the ground connection. Without the protective ground connection, all accessible conductive parts (including control knobs) can render an electric shock. The power jack and mating plug of the power cable meet IEC safety standards.
DO NOT OPERATE IN AN EXPLOSIVE ATMOSPHERE
Do not operate the instrument in the presence of flammable gases or fumes. Operation of any electrical instrument in such an environment constitutes a definite safety hazard.
KEEP AWAY FROM LIVE CIRCUITS
Instrument covers must not be removed by operating personnel. Component replacement and internal adjustments must be made by qualified maintenance personnel. Disconnect the power cord before removing the instrument covers and replacing components. Under certain conditions, even with the power cable removed, dangerous voltages may exist. To avoid injuries, always disconnect power and discharge circuits before touching them.
DO NOT SERVICE OR ADJUST ALONE
Do not attempt any internal service or adjustment unless another person, capable of rendering first aid and resuscitation, is present.
DO NOT SUBSTITUTE PARTS OR MODIFY THE INSTRUMENT
Do not install substitute parts or perform any unauthorized modifications to this instrument. Return the instrument to B&K Precision for service and repair to ensure that safety features are maintained.
1
WARNINGS AND CAUTIONS
WARNING and CAUTION statements, such as the following examples, denote a
hazard and appear throughout this manual. Follow all instructions contained in these statements.
A WARNING statement calls attention to an operating procedure, practice, or condition, which, if not followed correctly, could result in injury or death to personnel.
A CAUTION statement calls attention to an operating procedure, practice, or condition, which, if not followed correctly, could result in damage to or destruction of parts or the entire product.
WARNING:
WARNING:
CAUTION:
CAUTION:
Do not alter the ground connection. Without the protective ground connection, all accessible conductive parts (including control knobs) can render an electric shock. The power jack and mating plug of the power cable meet IEC safety standards.
To avoid electrical shock hazard, disconnect power cord before removing covers. Refer servicing to qualified personnel.
Before connecting the line cord to the AC mains, check the rear panel AC line voltage indicator. Applying a line voltage other than the indicated voltage can destroy the AC line fuses. For continued fire protection, replace fuses only with those of the specified voltage and current ratings.
This product uses components which can be damaged by electro­static discharge (ESD). To avoid damage, be sure to follow proper procedures for handling, storing and transporting parts and subassemblies which contain ESD-sensitive components.
SAFETY SYMBOLS
Connect to safety earth ground using the wire recommended in the user
manual.
This symbol on an instrument indicates that the user should refer to the
operating instructions located in the manual.
Certification
We certify that this product met its published specifications at time of shipment from the
factory.
2
Compliance Statements
Disposal of Old Electrical & Electronic Equipment (Applicable in the European Union and
other European countries with separate collection systems)
This product is subject to Directive 2002/96/EC of the European
Parliament and the Council of the European Union on waste
electrical and electronic equipment (WEEE), and in jurisdictions
adopting that Directive, is marked as being put on the market
after August 13, 2005, and should not be disposed of as
unsorted municipal waste. Please utilize your local WEEE
collection facilities in the disposition of this product and
otherwise observe all applicable requirements.
3
Contents
1
Safety Summary .......................................................... 1
2 Introduction ................................................................ 5
3 Quick Reference .......................................................... 6
3.1 Front Panel ......................................................................................... 6
3.2 Rear Panel .......................................................................................... 7
4 Operating Instructions ................................................. 8
4.1 Instrument Hook-Up .......................................................................... 9
4.2 Typical Constant Voltage Operation ................................................. 11
4.3 Setting Current Limit ........................................................................ 12
4.4 Typical Constant Current Operation ................................................ 12
4.5 Constant Voltage/Constant Current Characteristic .......................... 13
4.6 Saving the Power Supply’s Current State ......................................... 14
4.7 Connecting Two Power Supplies in Series ....................................... 15
4.8 Connecting Two Power Supplies in Parallel ..................................... 15
5 Remote Operation ...................................................... 17
5.1 RS232 Configuration Overview ........................................................ 18
5.2 RS232 Commands ............................................................................ 18
5.3 Application Software ....................................................................... 20
6 Maintenance .............................................................. 21
6.1 Fuse Replacement............................................................................ 21
6.2 Adjustments ..................................................................................... 22
6.3 Calibration ....................................................................................... 22
6.4 Instrument Repair Service ............................................................... 27
7 Error Messages ........................................................... 27
7.1 Self-Test Errors ................................................................................. 27
7.2 Calibration Errors ............................................................................. 28
7.3 Command Errors .............................................................................. 29
8 Specifications ............................................................. 30
9 Service Information .................................................... 32
10 Limited Two-Year Warranty ........................................ 33
4

2 Introduction

Description
The B&K Precision model 1747 is a general purpose dual range DC power source. This power supply can output more voltage at a lower current or more current at a lower voltage. The 1747 provides 0-60 V DC output, adjustable with both coarse and fine voltage controls for precise setting. The current output for the 1747 is 0-10 A for the 0-35 V range, and 0-5 A for the 35-60 V range, adjustable with both coarse and fine current controls.
The 1747 exhibits excellent regulation and low ripple characteristics. Its mechanical configuration conserves bench space and allows for easy portability. Additionally, the power supply can be operated locally from the front panel or remotely through the RS-232 interface.
This power supply is well suited for a wide variety of electrical and electronics applications in service shops, engineering labs, production facilities, school laboratories, and home use.
Features
Low ripple and noise
Excellent regulation
Constant voltage (CV) and constant current (CC) mode operation
Two 4-digit LED displays provide good visibility in bright or low light
LED indication for CV and CC modes
Automatic recall of last settings on power up
RS-232 interface
Isolated output
Overload protection
Reverse polarity protection
5
Loading...
+ 15 hidden pages