The following safety precautions apply to both operating and maintenance personnel and
must be observed during all phases of operation, service, and repair of this instrument.
Before applying power, follow the installation instructions and become familiar with the
operating instructions for this instrument.
GROUND THE INSTRUMENT
To minimize shock hazard, the instrument chassis and cabinet must be
connected to an electrical ground. This instrument is grounded through the
ground conductor of the supplied, three-conductor ac power cable. The power
cable must be plugged into an approved three-conductor electrical outlet. Do not
alter the ground connection. Without the protective ground connection, all
accessible conductive parts (including control knobs) can render an electric
shock. The power jack and mating plug of the power cable meet IEC safety
standards.
DO NOT OPERATE IN AN EXPLOSIVE ATMOSPHERE
Do not operate the instrument in the presence of flammable gases or fumes.
Operation of any electrical instrument in such an environment constitutes a
definite safety hazard.
KEEP AWAY FROM LIVE CIRCUITS
Instrument covers must not be removed by operating personnel. Component
replacement and internal adjustments must be made by qualified maintenance
personnel. Disconnect the power cord before removing the instrument covers
and replacing components. Under certain conditions, even with the power cable
removed, dangerous voltages may exist. To avoid injuries, always disconnect
power and discharge circuits before touching them.
DO NOT SERVICE OR ADJUST ALONE
Do not attempt any internal service or adjustment unless another person,
capable of rendering first aid and resuscitation, is present.
DO NOT SUBSTITUTE PARTS OR MODIFY THE INSTRUMENT
Do not install substitute parts or perform any unauthorized modifications to this
instrument. Return the instrument to B&K Precision for service and repair to
ensure that safety features are maintained.
1
WARNINGS AND CAUTIONS
WARNING and CAUTION statements, such as the following examples, denote a
hazard and appear throughout this manual. Follow all instructions contained in
these statements.
A WARNING statement calls attention to an operating procedure, practice, or
condition, which, if not followed correctly, could result in injury or death to
personnel.
A CAUTION statement calls attention to an operating procedure, practice, or
condition, which, if not followed correctly, could result in damage to or
destruction of parts or the entire product.
WARNING:
WARNING:
CAUTION:
CAUTION:
Do not alter the ground connection. Without the protective
ground connection, all accessible conductive parts (including
control knobs) can render an electric shock. The power jack and
mating plug of the power cable meet IEC safety standards.
To avoid electrical shock hazard, disconnect power cord before
removing covers. Refer servicing to qualified personnel.
Before connecting the line cord to the AC mains, check the rear
panel AC line voltage indicator. Applying a line voltage other
than the indicated voltage can destroy the AC line fuses. For
continued fire protection, replace fuses only with those of the
specified voltage and current ratings.
This product uses components which can be damaged by electrostatic discharge (ESD). To avoid damage, be sure to follow
proper procedures for handling, storing and transporting parts
and subassemblies which contain ESD-sensitive components.
SAFETY SYMBOLS
Connect to safety earth ground using the wire recommended in the user
manual.
This symbol on an instrument indicates that the user should refer to the
operating instructions located in the manual.
Certification
We certify that this product met its published specifications at time of shipment from the
factory.
2
Compliance Statements
Disposal of Old Electrical & Electronic Equipment (Applicable in the European Union and
other European countries with separate collection systems)
This product is subject to Directive 2002/96/EC of the European
Parliament and the Council of the European Union on waste
electrical and electronic equipment (WEEE), and in jurisdictions
adopting that Directive, is marked as being put on the market
after August 13, 2005, and should not be disposed of as
unsorted municipal waste. Please utilize your local WEEE
collection facilities in the disposition of this product and
The B&K Precision model 1747 is a general purpose dual range DC power source.
This power supply can output more voltage at a lower current or more current at
a lower voltage. The 1747 provides 0-60 V DC output, adjustable with both
coarse and fine voltage controls for precise setting. The current output for the
1747 is 0-10 A for the 0-35 V range, and 0-5 A for the 35-60 V range, adjustable
with both coarse and fine current controls.
The 1747 exhibits excellent regulation and low ripple characteristics. Its
mechanical configuration conserves bench space and allows for easy portability.
Additionally, the power supply can be operated locally from the front panel or
remotely through the RS-232 interface.
This power supply is well suited for a wide variety of electrical and electronics
applications in service shops, engineering labs, production facilities, school
laboratories, and home use.
Features
• Low ripple and noise
• Excellent regulation
• Constant voltage (CV) and constant current (CC) mode operation
• Two 4-digit LED displays provide good visibility in bright or low light
• LED indication for CV and CC modes
• Automatic recall of last settings on power up
• RS-232 interface
• Isolated output
• Overload protection
• Reverse polarity protection
5