Binder APT.line FD, APT.line ED, APT.line BD Instruction Manual

Operating Manual
APT.line® BD (E2)
Incubators with natural convection
APT.line® ED (E2)
APT.line® FD (E2)
Heating/drying ovens with forced convection
with R3 Controller
BINDER GmbH
Address Post office box 102 D-78502 Tuttlingen Tel. +49 7462 2005 0 Fax +49 7462 2005 93 0 Internet http://www.binder-world.com E-mail info@binder-world.com Service Hotline +49 7462 2005 555 Service Fax +49 7462 2005 93 555 Service E-Mail service@binder-world.com Service Hotline USA +1 866 816 8191 Service Hotline Asia Pacific +603 6204 2855
Issue 01/2006 Art. No. 7001-0026
EG - KONFORMITÄTSERKLÄRUNG EC - DECLARATION OF CONFORMITY CE - DECLARATION DE CONFORMITE
Anbieter / Supplier / Fournisseur: Anschrift / Address / Adresse : Produkt / Product / Produit:
BINDER GmbH Im Mittleren Ösch 5, D-78532 Tuttlingen Brutschränke mit natürlicher Umluft
Incubators with natural convection Incubateurs à circulation d’air naturelle
Typenbezeichnung / Type / Type BD 23, BD 53, BD 115, BD 240, BD 400, BD 720
Die oben beschriebenen Produkte sind konform mit folgenden harmonisierten Normen: The products described above are in conformity with the following harmonized standards: Les produits décrits ci-dessus sont conformes aux normes harmonisées suivantes:
Sicherheit / safety / sécurité:
IEC/CEI 61010-1:2001 Sicherheitsbestimmungen für elektrische Mess-, Steuer-, Regel-
und Laborgeräte – Teil 1: Allgemeine Anforderungen Safety requirements for electrical equipment for measurement,
control, and laboratory use – Part 1: General requirements Règles de sécurité pour appareils électriques de mesurage, de
régulation et de laboratoire – Partie 1 : Prescriptions générales
IEC/CEI 61010-2-010:2003 Sicherheitsbestimmungen für elektrische Meß-, Steuer-, Regel-
und Laborgeräte – Teil 2-010: Besondere Anforderungen an Laborgeräte für das Erhitzen von Stoffen
Safety requirements for electrical equipment for measurement, control, and laboratory use – Part 2-010: Particular requirements for laboratory equipment for the heating of materials
Règles de sécurité pour appareils électriques de mesurage, de régulation et de laboratoire. Partie 2-010 : Prescriptions particulières pour appareils de laboratoire utilisés pour
l’échauffement des matières EMV / EMC / CEM: IEC/CEI 61326:1997 + A1:1998 +
A2:2000
Elektrische Betriebsmittel für Leittechnik und Laboreinsatz – EMV-
Anforderungen
Electrical equipment for measurement, control and laboratory use
– EMC requirements
Matériels électriques de mesure, de commande et de laboratoire
– Prescriptions relatives à la CEM
1 / 2
BD / ED / FD 01/2006 page 2/49
Die oben beschriebenen Produkte sind konform mit folgenden EG-Richtlinien: The products described above are in conformity with the following EC guidelines: Les produits décrits ci-dessus sont conformes aux directives CE suivantes:
Niederspannungsrichtlinie 73/23/EWG, Änderung 93/68/EWG
Low voltage directive 73/23/EEC, amended 93/68/EEC
Directive basse tension 73/23/CEE, modifiée 93/68/CEE
Richtlinie 73/23/EWG des Rates vom 19. Februar 1973 zur
Angleichung der Rechtsvorschriften der Mitgliedstaaten betreffend
elektrische Betriebsmittel zur Verwendung innerhalb bestimmter
Spannungsgrenzen
Council Directive of 19 February 1973 on the harmonization of the
laws of Member States relating to electrical equipment designed
for use within certain voltage limits (73/23/EEC)
Directive 73/23/CEE du Conseil, du 19 février 1973, concernant le
rapprochement des législations des États membres relatives au
matériel électrique destiné à être employé dans certaines limites
de tension EMV-Richtlinie
89/336/EWG, Änderung 93/68/EWG EMC Directive
89/336/EEC, amended 93/68/EEC Directive CEM
89/336/CEE, modifiée 93/68/CEE
Richtlinie 89/336/EWG des Rates vom 3. Mai 1989 zur
Angleichung der Rechtsvorschriften der Mitgliedstaaten über die
elektromagnetische Verträglichkeit
Council Directive 89/336/EEC of 3 May 1989 on the
approximation of the laws of the Member States relating to
electromagnetic compatibility
Directive 89/336/CEE du Conseil du 3 mai 1989 concernant le
rapprochement des législations des États membres relatives à la
compatibilité électromagnétique
Die oben beschriebenen Produkte tragen entsprechend die Kennzeichnung CE. The products described above, corresponding to this, bear the CE-mark Les produits décrits ci-dessus, en correspondance, portent l’indication CE.
D-78532 Tuttlingen, 10.01.2006
BINDER GmbH
P. M. Binder Dr.-Ing. V. Kek Geschäftsführender Gesellschafter Leiter F & E Managing Director Head of R & D Directeur général Chef de service R&D
2 / 2
BD / ED / FD 01/2006 page 3/49
EG - KONFORMITÄTSERKLÄRUNG EC - DECLARATION OF CONFORMITY CE - DECLARATION DE CONFORMITE
Anbieter / Supplier / Fournisseur: Anschrift / Address / Adresse : Produkt / Product / Produit:
BINDER GmbH
Im Mittleren Ösch 5, D-78532 Tuttlingen
Wärme-/Trockenschränke mit natürlicher Umluft
Heating/drying ovens with natural convection
Etuves universelles à circulation d’air naturelle Typenbezeichnung / Type / Type ED 23, ED 53, ED 115, ED 240, ED 400, ED 720
Die oben beschriebenen Produkte sind konform mit folgenden harmonisierten Normen: The products described above are in conformity with the following harmonized standards: Les produits décrits ci-dessus sont conformes aux normes harmonisées suivantes:
Sicherheit / safety / sécurité:
IEC/CEI 61010-1:2001 Sicherheitsbestimmungen für elektrische Mess-, Steuer-, Regel-
und Laborgeräte – Teil 1: Allgemeine Anforderungen
Safety requirements for electrical equipment for measurement,
control, and laboratory use – Part 1: General requirements
Règles de sécurité pour appareils électriques de mesurage, de
régulation et de laboratoire – Partie 1 : Prescriptions générales IEC/CEI 61010-2-010:2003 Sicherheitsbestimmungen für elektrische Meß-, Steuer-, Regel-
und Laborgeräte – Teil 2-010: Besondere Anforderungen an
Laborgeräte für das Erhitzen von Stoffen
Safety requirements for electrical equipment for measurement,
control, and laboratory use – Part 2-010: Particular requirements
for laboratory equipment for the heating of materials
Règles de sécurité pour appareils électriques de mesurage, de
régulation et de laboratoire. Partie 2-010 : Prescriptions
particulières pour appareils de laboratoire utilisés pour
l’échauffement des matières EMV / EMC / CEM: IEC/CEI 61326:1997 + A1:1998 +
A2:2000
Elektrische Betriebsmittel für Leittechnik und Laboreinsatz – EMV-
Anforderungen
Electrical equipment for measurement, control and laboratory use
– EMC requirements
Matériels électriques de mesure, de commande et de laboratoire
– Prescriptions relatives à la CEM
1 / 2
BD / ED / FD 01/2006 page 4/49
Die oben beschriebenen Produkte sind konform mit folgenden EG-Richtlinien: The products described above are in conformity with the following EC guidelines: Les produits décrits ci-dessus sont conformes aux directives CE suivantes:
Niederspannungsrichtlinie 73/23/EWG, Änderung 93/68/EWG
Low voltage directive 73/23/EEC, amended 93/68/EEC
Directive basse tension 73/23/CEE, modifiée 93/68/CEE
Richtlinie 73/23/EWG des Rates vom 19. Februar 1973 zur
Angleichung der Rechtsvorschriften der Mitgliedstaaten betreffend
elektrische Betriebsmittel zur Verwendung innerhalb bestimmter
Spannungsgrenzen
Council Directive of 19 February 1973 on the harmonization of the
laws of Member States relating to electrical equipment designed
for use within certain voltage limits (73/23/EEC)
Directive 73/23/CEE du Conseil, du 19 février 1973, concernant le
rapprochement des législations des États membres relatives au
matériel électrique destiné à être employé dans certaines limites
de tension EMV-Richtlinie
89/336/EWG, Änderung 93/68/EWG EMC Directive
89/336/EEC, amended 93/68/EEC Directive CEM
89/336/CEE, modifiée 93/68/CEE
Richtlinie 89/336/EWG des Rates vom 3. Mai 1989 zur
Angleichung der Rechtsvorschriften der Mitgliedstaaten über die
elektromagnetische Verträglichkeit
Council Directive 89/336/EEC of 3 May 1989 on the
approximation of the laws of the Member States relating to
electromagnetic compatibility
Directive 89/336/CEE du Conseil du 3 mai 1989 concernant le
rapprochement des législations des États membres relatives à la
compatibilité électromagnétique
Die oben beschriebenen Produkte tragen entsprechend die Kennzeichnung CE. The products described above, corresponding to this, bear the CE-mark Les produits décrits ci-dessus, en correspondance, portent l’indication CE.
D-78532 Tuttlingen, 10.01.2006
BINDER GmbH
P. M. Binder Dr.-Ing. V. Kek Geschäftsführender Gesellschafter Leiter F & E Managing Director Head of R & D Directeur général Chef de service R&D
2 / 2
BD / ED / FD 01/2006 page 5/49
EG - KONFORMITÄTSERKLÄRUNG EC - DECLARATION OF CONFORMITY CE - DECLARATION DE CONFORMITE
Anbieter / Supplier / Fournisseur: Anschrift / Address / Adresse : Produkt / Product / Produit:
BINDER GmbH
Im Mittleren Ösch 5, D-78532 Tuttlingen
Wärme-/Trockenschränke mit forcierter Umluft
Heating/drying ovens with forced convection
Etuves universelles à circulation d’air forcée Typenbezeichnung / Type / Type FD 23, FD 53, FD 115, FD 240
Die oben beschriebenen Produkte sind konform mit folgenden harmonisierten Normen: The products described above are in conformity with the following harmonized standards: Les produits décrits ci-dessus sont conformes aux normes harmonisées suivantes:
Sicherheit / safety / sécurité:
IEC/CEI 61010-1:2001 Sicherheitsbestimmungen für elektrische Mess-, Steuer-, Regel-
und Laborgeräte – Teil 1: Allgemeine Anforderungen
Safety requirements for electrical equipment for measurement,
control, and laboratory use – Part 1: General requirements
Règles de sécurité pour appareils électriques de mesurage, de
régulation et de laboratoire – Partie 1 : Prescriptions générales IEC/CEI 61010-2-010:2003 Sicherheitsbestimmungen für elektrische Meß-, Steuer-, Regel-
und Laborgeräte – Teil 2-010: Besondere Anforderungen an
Laborgeräte für das Erhitzen von Stoffen
Safety requirements for electrical equipment for measurement,
control, and laboratory use – Part 2-010: Particular requirements
for laboratory equipment for the heating of materials
Règles de sécurité pour appareils électriques de mesurage, de
régulation et de laboratoire. Partie 2-010 : Prescriptions
particulières pour appareils de laboratoire utilisés pour
l’échauffement des matières EMV / EMC / CEM: IEC/CEI 61326:1997 + A1:1998 +
A2:2000
Elektrische Betriebsmittel für Leittechnik und Laboreinsatz – EMV-
Anforderungen
Electrical equipment for measurement, control and laboratory use
– EMC requirements
Matériels électriques de mesure, de commande et de laboratoire
– Prescriptions relatives à la CEM
1 / 2
BD / ED / FD 01/2006 page 6/49
Die oben beschriebenen Produkte sind konform mit folgenden EG-Richtlinien: The products described above are in conformity with the following EC guidelines: Les produits décrits ci-dessus sont conformes aux directives CE suivantes:
Niederspannungsrichtlinie 73/23/EWG, Änderung 93/68/EWG
Low voltage directive 73/23/EEC, amended 93/68/EEC
Directive basse tension 73/23/CEE, modifiée 93/68/CEE
Richtlinie 73/23/EWG des Rates vom 19. Februar 1973 zur
Angleichung der Rechtsvorschriften der Mitgliedstaaten betreffend
elektrische Betriebsmittel zur Verwendung innerhalb bestimmter
Spannungsgrenzen
Council Directive of 19 February 1973 on the harmonization of the
laws of Member States relating to electrical equipment designed
for use within certain voltage limits (73/23/EEC)
Directive 73/23/CEE du Conseil, du 19 février 1973, concernant le
rapprochement des législations des États membres relatives au
matériel électrique destiné à être employé dans certaines limites
de tension EMV-Richtlinie
89/336/EWG, Änderung 93/68/EWG EMC Directive
89/336/EEC, amended 93/68/EEC Directive CEM
89/336/CEE, modifiée 93/68/CEE
Richtlinie 89/336/EWG des Rates vom 3. Mai 1989 zur
Angleichung der Rechtsvorschriften der Mitgliedstaaten über die
elektromagnetische Verträglichkeit
Council Directive 89/336/EEC of 3 May 1989 on the
approximation of the laws of the Member States relating to
electromagnetic compatibility
Directive 89/336/CEE du Conseil du 3 mai 1989 concernant le
rapprochement des législations des États membres relatives à la
compatibilité électromagnétique
Die oben beschriebenen Produkte tragen entsprechend die Kennzeichnung CE. The products described above, corresponding to this, bear the CE-mark Les produits décrits ci-dessus, en correspondance, portent l’indication CE.
D-78532 Tuttlingen, 10.01.2006
BINDER GmbH
P. M. Binder Dr.-Ing. V. Kek Geschäftsführender Gesellschafter Leiter F & E Managing Director Head of R & D Directeur général Chef de service R&D
2 / 2
BD / ED / FD 01/2006 page 7/49
Content
1. SAFETY................................................................................................................ 10
1.1 Legal considerations .........................................................................................................................10
1.2 Structure of the safety instructions....................................................................................................10
1.3 Localization / position of safety labels at the unit..............................................................................12
1.4 Type plate .........................................................................................................................................13
1.5 General safety instructions on installing and operating the incubators BD and heating/drying ovens
ED and FD ........................................................................................................................................13
1.6 Intended use .....................................................................................................................................15
1.6.1 Incubators BD..........................................................................................................................15
1.6.2 Heating/drying ovens ED and FD............................................................................................15
2. WARRANTY......................................................................................................... 15
3. UNIT DESCRIPTION ............................................................................................ 17
3.1 Equipment overview BD/ED/FD........................................................................................................17
4. SCOPE OF DELIVERY, TRANSPORTATION, STORAGE, AND INSTALLATION18
4.1 Unpacking, and checking equipment and scope of delivery.............................................................18
4.2 Advice for safe lifting and transportation...........................................................................................18
4.3 Storage..............................................................................................................................................19
4.4 Location of installation and ambient conditions ................................................................................19
5. INSTALLATION OF THE EQUIPMENT ............................................................... 20
5.1 Electrical connection .........................................................................................................................20
5.2 Connection to a suction plant (optional) ...........................................................................................20
6. START UP............................................................................................................ 21
6.1 Switching on the unit.........................................................................................................................21
6.2 Heating operation display .................................................................................................................21
6.3 Air change .........................................................................................................................................21
7. CONTROLLER SETTING..................................................................................... 22
7.1 Display / entry of temperature set-point (without ramp function) ......................................................22
7.2 Display / entry of temperature set-point (with selected temperature ramp)......................................22
7.3 Time functions: Continuous operation and Timer operation.............................................................23
7.3.1 Switching between Continuous operation and Timer operation .............................................24
7.3.2 Continuous operation ..............................................................................................................24
7.3.3 Timer operation: Setting the tempering time ........................................................................... 25
7.4 User level settings.............................................................................................................................26
7.4.1 Temperature unit change between degrees Celsius °C and degrees Fahrenheit °F .............26
7.4.2 Enter a temperature ramp .......................................................................................................27
7.4.3 Chamber addressing ...............................................................................................................27
7.5 General notes....................................................................................................................................28
8. SAFETY DEVICES ............................................................................................... 29
8.1 Temperature safety device class 2 (DIN 12880) ED, FD .................................................................29
8.2 Temperature safety device class 3.1 (DIN 12880) BD (option ED, FD))..........................................30
9. OPTIONS.............................................................................................................. 31
9.1 Disconnectable acoustic over-temperature alarm (option)...............................................................31
9.2 Communication software APT-COM® 3 DataControlSystem (BD, option ED) .................................32
9.3 Analog output for temperature (option).............................................................................................32
9.4 Additional Pt100 temperature sensor (option BD) ............................................................................32
9.5 Water protected internal socket (option BD).....................................................................................33
BD / ED / FD 01/2006 page 8/49
10. MAINTENANCE, CLEANING, AND SERVICE .................................................... 33
10.1 Maintenance intervals, service..........................................................................................................33
10.2 Cleaning and decontamination .........................................................................................................34
11. DISPOSAL............................................................................................................ 35
11.1 Disposal of the transport packing .....................................................................................................35
11.2 Decommissioning..............................................................................................................................36
11.3 Disposal of the unit............................................................................................................................36
12. TECHNICAL DESCRIPTION................................................................................ 36
12.1 Factory calibration and adjustment...................................................................................................36
12.2 Definition of usable space.................................................................................................................36
12.3 Over current protection .....................................................................................................................37
12.4 Technical data series BD ..................................................................................................................37
12.5 Technical data series ED ..................................................................................................................39
12.6 Technical data series FD ..................................................................................................................40
12.7 Equipment and Options Series BD ...................................................................................................42
12.8 Equipment and Options Series ED ...................................................................................................43
12.9 Equipment and Options Series FD ...................................................................................................44
12.10 Spare parts........................................................................................................................................45
13. CONTAMINATION CLEARANCE CERTIFICATE ............................................... 47
BD / ED / FD 01/2006 page 9/49
Dear customer,
For the proper operation of the incubators BD and heating/drying ovens ED and FD, it is necessary to read this operating manual completely and carefully and to observe the given instructions.
1. Safety
This operating manual is part of the scope of delivery. Always keep it at hand. To avoid injuries and damage observe the safety instructions of the operating manual.
WARNING
Failure to observe the safety instructions.
Serious injuries and unit damage.
Observe the safety instructions in this operating manual Carefully read the complete operating instructions of the incubators BD and
heating/drying ovens ED and FD
1.1 Legal considerations
This operating manual contains information necessary for the intended use, correct installation, start-up and operation, and for the maintenance of the unit.
Understanding and observing the instructions in this operating manual are prerequisites for hazard-free use and safety during operation and maintenance.
This operating manual cannot cover all conceivable applications. If you would like additional information, or if special problems arise that you feel are not sufficiently addressed in this manual, please ask your dealer or contact us directly.
Furthermore, we note that the contents of this operating manual are not part of an earlier or existing agreement, promise, or legal relationship, nor do they modify such a relationship. All obligations on the part of BINDER derive from the respective purchase contract, which also contains the entire and exclusively valid statement of warranty administration. The statements in this manual neither augment nor restrict the contractual warranty provisions.
1.2 Structure of the safety instructions
In this operating manual, the following harmonized denominations and symbols indicate dangerous situations following the harmonization of ISO 3864-2 and ANSI Z535.4.
Signal word panel
Depending on seriousness and probability of the consequences, dangers are identified with a signal word, the corresponding safety color, and if appropriate, the safety alert symbol.
DANGER
Indicates an imminently hazardous situation that, if not avoided, will result in death or serious (irreversible) injury.
WARNING
Indicates a potentially hazardous situation which, if not avoided, could result in death or serious (irreversible) injury
BD / ED / FD 01/2006 page 10/49
CAUTION
Indicates a potentially hazardous situation which, if not avoided, may result in moderate or minor (reversible) injury
CAUTION
Indicates a potentially hazardous situation which, if not avoided, may result in damage of the product and/or its functions or of a property in its ambiance.
Safety alert symbol
Use of the safety alert symbol indicates risk of injury. Observe all measures that are marked with the safety alert symbol in order to avoid death or
injury.
Pictograms
Warning signs
Electrical hazard
Hot surface
Tipover hazard
Mandatory action signs
Mandatory regulation
Read operating instructions
Pull the power plug
Explosive substances
Pollution Hazard
Lift with several persons
Lift with mechanical assistance
Environment protection
Prohibition signs
Do NOT touch
Do NOT spray with water
BD / ED / FD 01/2006 page 11/49
Information to be observed in order to ensure optimum function of the product.
Word message panel structure
Type / cause of hazard. Possible consequences.
Instruction how to avoid the hazard: prohibition
Instruction how to avoid the hazard: mandatory action
Observe the other notes and information not specially emphasized in the same way, in order to avoid disturbances which could result in direct or indirect injuries or property damage.
1.3 Localization / position of safety labels at the unit
Following labels are located on the unit:
Pictograms (Warning signs) Service label
Hot surface
Figure 1: Position of labels at the unit
Keep safety labels complete and legible.
BD / ED / FD 01/2006 page 12/49
A
1.4 Type plate
Nenntemperatur 300°C 1,60 kW
572°F 230 V 1 N ~
Schutzart IP 20 7,0 A Temp. Schutz DIN 12880 50/60 Hz Klasse 2.0
rtikel-Nr. 9010-0102 US PATS 5405194 / 5222612
Projekt-Nr. US PATS 4585923 / 5309981
D 78532 Tuttlingen / Germany Tel. + 49 (0) 7462 / 2005-0 Internet: www.binder-world.com
FD 115 # 00-00000
Made in Germany
Figure 2: Type plate (example: FD 115 regular unit)
Indications of the type plate Information
Nenntemperatur 300°C
Nominal temperature
572°F Schutzart IP 20 IP type of protection 20 acc. to EN 60529 Temp. Schutz DIN 12880 Temperature safety device acc. to standard DIN 12880 Klasse 2.0 Temperature safety device, class 2 Artikel-Nr. 9010-0102 Art. No. 9010-0102 Projekt-Nr. --- (Special application acc. to project no.) 1,60 kW Nominal power 1.60 kW 230 V 1 N ~
Nominal voltage 230 V ± 10%, single-phase unit 7,0 A Nominal current 7.0 A 50/60 Hz Mains supply 50/60 Hz FD 115 Model FD 115 # 00-00000 Serial No. 00-00000
1.5 General safety instructions on installing and operating the incubators BD
and heating/drying ovens ED and FD
With regard to operating the incubators BD and heating/drying ovens ED and FD and to the installation location, please observe the regulations BGR 120 of the German professional association of the chemical industry (formerly ZH 1/119 laboratory guidelines of the employers’ liability insurance association) (for Germany).
The BINDER GmbH is responsible for safety-related unit properties only if skilled electricians or qualified personnel authorized by BINDER perform all maintenance and repair, and if components relating to chamber safety are replaced in case of failure with original spare parts.
To operate the unit, use only original BINDER accessories or accessories of third-party suppliers authorized by BINDER. The user is responsible for any risk when using unauthorized accessories.
CAUTION
Danger of overheating. Damage of the unit.
Do not install the unit in unventilated recesses.
Ensure sufficient ventilation for carrying-off the heat.
BD / ED / FD 01/2006 page 13/49
The incubators BD and heating/drying ovens ED and FD must NOT be operated in hazardous locations.
DANGER
Explosion hazard. Danger of life.
Do NOT operate the unit in potentially explosive areas.
NO explosive dust or air-solvent mixture in the ambiance.
The incubators BD and heating/drying ovens ED and FD do not dispose of any measures of explosion protection.
DANGER
Explosion hazard. Danger of life.
Do NOT introduce any substance combustible or explosive at working temperature into
the heating/drying oven.
NO explosive dust or air-solvent mixture in the inner chamber.
Any solvent contained in the charging material must not be explosive or inflammable. I.e., irrespective of the solvent concentration in the steam room, NO explosive mixture with air will form. The temperature inside the chamber must lie below the flash point or below the sublimation point of the charging material. Keep informed about the physical and chemical properties of the charging material, as well as the contained moisture constituent and its behavior under addition of heat energy.
Keep informed about any potential health risks caused by the charging material, the contained moisture constituent or by reaction products that may arise during the temperature process. Take adequate measures to exclude such risks prior to putting the multifunctional heating/drying oven into operation.
DANGER
Electrical hazard. Danger of life.
The unit must NOT become wet during operation or maintenance.
The multifunctional heating/drying ovens have been produced in accordance to the VDE regulations and were routinely tested in accordance to VDE 0411.
CAUTION
The inner chamber, the outgoing air pipe, and the door window (option) will become hot during operation.
Danger of burning.
Do NOT touch the inner surfaces, the door window, the access ports, and the charging
material during operation.
BD / ED / FD 01/2006 page 14/49
1.6 Intended use
1.6.1 Incubators BD
The incubators BD are designed for exact temperation of harmless materials. Because of their precise temperature accuracy these devices are especially useful for incubation of cultures at a standard temperature of 37°C. Any solvent content must not be explosive or flammable. A mixture of any component of the charging material with air must NOT be explosive. The operating temperature must lie below the flash point or below the sublimation point of the charging material.
Other applications are not approved.
Do NOT use the unit for drying purpose, especially if greater quantities of steam leading to condensation will be set free.
Respecting the instructions in this operating manual and conducting regular maintenance work (chap. 10) is part of the intended use.
1.6.2 Heating/drying ovens ED and FD
The heating/drying ovens ED and FD are suitable for drying and heat treatment of solid or pulverized charging material, as well as bulk material, using the supply of heat. The solvent content must not be explosive or flammable. A mixture of any component of the charging material with air must NOT be explosive. The operating temperature must lie below the flash point or below the sublimation point of the charging material.
Other applications are not approved.
Do NOT use the unit for drying purpose, especially if greater quantities of steam leading to condensation will be set free.
Due to the special demands of the Medical Device Directive (MDD) this ovens are not qualified for sterilization of medical devices as defined by the directive 93/42/EWG.
Respecting the instructions in this operating manual and conducting regular maintenance work (chap. 10) is part of the intended use.
2. Warranty
BINDER products are manufactured with great care and checked carefully prior to delivery (VDE-piece checked).
1. Should your BINDER product have a material defect or manufacturing fault, we shall repair it – as
long as it is a new BINDER product – free of charge if the defect or fault occurs within 12 months after delivery. This period will be extended to 24 months, starting from delivery, provided that all maintenance and potential repair work within the first 12 months is carried out by us or authorized service stations.
2. Should you discover a defect or fault in your BINDER product within the aforementioned period,
please inform the company from which you purchased the BINDER product or BINDER directly.
3. All above-mentioned periods or deadlines shall begin with the delivery of a new BINDER product to
the end buyer. Producing the invoice or delivery note shall bring evidence of deadline keeping.
4. In case a BINDER product has a defect or fault, we shall either replace the defective product with a
new one or repair the defective product at our discretion (so called supplementary performance – “Nacherfüllung”). All parts replaced in the course of such repair shall become our property. Deadlines mentioned under above number 1 shall not be prolonged by repair work or substitution. In case supplementary performance should fail, usual warranty rights according to German Law (withdrawal from contract or price reduction) shall apply, provided the defect or fault occurs within the first 12 months. Should the 24 month-period be relevant and supplementary performance fail, you shall only be entitled to a price reduction.
BD / ED / FD 01/2006 page 15/49
Loading...
+ 34 hidden pages