Included in delivery
1x Air purifier
1x combi filter (activated carbon/HEPA filter class E 10)
1x pre-filter
1x these instructions for use
WARNING
This device may be used by children over the age of eight and by people with reduced physical, sensory or mental skills or a lack of experience or knowledge, provided that they are supervised or have been instructed on how to use the device safely, and are fully aware of the consequent risks of use.
Children must not play with the device.
Cleaning and user maintenance must not be performed by children unless supervised.
Disconnect the device from the mains supply during cleaning.
Clean the device using only the methods specified. Under no circumstances must liquid enter the fan unit.
Do not use any solvent-based cleaning products.
If the mains connection cable of this device is damaged, it must be disposed of. If it cannot be removed, the device must be disposed of..
13
Table of contents
1. Getting to know your device...................14
2. Intended use ............................................ 15
3. Notes ........................................................15
4. Device description ................................... 17
5. Initial use .................................................. 18
5.1 Removing the air cleaner ..................... 18
5.2 Setting up the air cleaner .................... 18
5.3 Preparing for the application ............... 18
6. Operation ..................................................19
6.1 Switching on the air cleaner ............... 19
Signs and symbols
The following symbols appear in these instructions for use:
WARNING
Warning instruction indicating a risk of injury or damage to health
IMPORTANT
Safety note indicating possible damage to the device/accessory
Note
Note on important information
1. Getting to know your device
Humans spend a large proportion of their time indoors. The air indoors is often polluted with dust particles, pollen, animal hair, odours, harmful gases as well as various bacteria and viruses and, particularly in winter, is also too dry. Ambient air that is too dry and contaminated may have a number of negative eects. The LR 330 air purifier humidifies air that is too dry and simultaneously cleans the air with a 3-layer filter system.
The LR 330 air purifier
Washes and humidifies air particularly hygienically
Filters air with a combi filter (Activated carbon filter against harmful gases and unpleasant odours, HEPA filter E 10 against particles such as bacteria, viruses, mites, pollen and fine dust)
Operates quietly with three output levels
Can humidify a room up to a preset target humidity (e.g. 55% air humidity)
Has a timer function (1 to 12 hours)
Suitable for rooms up to 35 m² in size
Consumes little energy and automatically switches o if the water runs out
6.2 Timer function .................................... 19
6.3 Selecting the humidity level ................ 19
6.4 Setting the target humidity ................. 19
6.5 Empty water tank ...............................19
Replacing the combi filter and pre-filter .
6.6
7. Cleaning and storage .............................. 20
8. What if there are problems? ................... 22
9. Disposal .................................................... 22
10. Replacement parts and wearing parts 22
11. Technical data ........................................ 22
20
Principle of air cleaning
1. The quiet and low-energy fan sucks the contaminated air in from the side air inlet.
2. The contaminated air is pre-cleaned by the built-in combi filter (activated carbon filter/HEPA filter). In ad dition, the pre-filter filters larger particles and hairs (in general) from the air.
3. The air passes over the disc set that continuously rotates in the tray and picks up calcium-free humidity.
4.
The cleaned air that is enriched with water is emitted via the air outlet on top of the Air purifier into the ambient air.
The HEPA E 10 filter has a filter performance of 85%. That means that 85% of particles (e.g.bacteria, viruses and fine dust) can be filtered out.
14
-
A relative humidity of between 40 and 60% is generally recommended. This value is often not reached in winter when cold air enters living spaces that are being aired and is then warmed up. Air can absorb more humidity in line with increasing air temperature. The air tries to compensate by taking humidity from other sources such as mucous membranes, skin, furniture and accessories, etc. This may have a number of negative eects:
Mucous membranes dry out, lips become chapped and dry, eyes become irritated
Exhaustion, tiredness and diculty concentrating
Pets and plants are put under unnecessary strain
Promotion of dust and electrostatic charging of textiles made of synthetic fibres, carpets and plastic floor coverings
Damage to furniture made of wood, particularly parquet floors
Detuning of musical instruments
Contaminated, unfiltered air can have the following eects:
Infections and respiratory diseases are more likely to occur
Damage to health through harmful gases
2. Intended use
This Air purifier is intended to clean and humidify the air indoors.
WARNING
If you suer from severe respiratory or lung disease, consult your doctor before using the Air purifier. This device must only be used for the purpose for which it was designed and in the manner specified in the instructions for use. Improper use can be dangerous. The manufacturer is not liable for damage resulting from improper or careless use.
3. Notes
Read the notes carefully! Non-observance of the following information may result in personal injury or ma­terial damage.
WARNING
Keep packaging material away from children to avoid danger of suocation.
Electric shock
WARNING
As with every electrical device, use this Air purifier carefully and cautiously, in order to avoid hazards due to electric shock.
• Therefore, observe the following instructions for use:
– do not operate the device at voltages other than those indicated on the device (the type plate is located
underneath the device) – never if it or its accessories show visible signs of damage – not during a thunderstorm
In the event of defects or operational faults, switch the device o immediately and disconnect it from the mains socket. Do not pull on the mains cable or on the device to disconnect the plug from the socket. Never hold or carry the device by the mains cable. Keep the cables away from hot surfaces.
Always switch o the device before disconnecting it from the mains.
Never disconnect the mains plug with wet or damp hands.
Keep the device away from sources of heat as the housing could melt and trigger a fire.