Beurer LR300 User Manual

Page 1
ENGLISH
Read these instructions for use carefully and keep them for later use, be sure to make them accessible to other users and observe the information they contain.
Dear customer,
Thank you for choosing one of our products. Our name stands for high-quality, thoroughly tested products for applications in the areas of heat, gentle therapy, blood pressure/diagnosis, weight, massage, beauty, air and babycare.
With kind regards, Your Beurer team
Included in delivery
1x air cleaner
1x combi filter (activated carbon/HEPA filter class E 12)
1x pre-filter
1 x set of instructions for use
WARNING
This device may be used by children over the age of eight and by people with reduced physical, sensory or mental skills or a lack of experience or knowledge, provided that they are supervised or have been instructed on how to use the device safely, and are fully aware of the consequent risks of use.
Children must not play with the device.
Cleaning and user maintenance must not be performed by children unless supervised.
Disconnect the device from the mains supply during cleaning.
Clean the device using only the methods specified. Under no circumstances must liquid enter the fan unit.
Do not use any solvent-based cleaning products.
If the mains connection cable of this device is damaged, it must be disposed of.
12
Page 2
Table of contents
1. Getting to know your device ..................13
2. Intended use ............................................14
3. Notes ........................................................14
4. Device description ..................................15
5. Initial use .................................................. 16
5.1 Removing the air cleaner .....................16
5.2 Setting up the air cleaner .................... 16
6. Operation .................................................17
6.1 Switching on the air cleaner ................ 17
6.2 Automatic function .............................. 17
6.3 Fan speed ............................................ 17
6.4 UV-C light ............................................ 17
Signs and symbols
The following symbols appear in these instructions for use:
WARNING
Warning instruction indicating a risk of injury or damage to health
IMPORTANT
Safety note indicating possible damage to the device/accessory
Note
Note on important information
6.5 Timer function....................................17
6.6 Filter change ...................................... 18
7. Cleaning and storage ............................ 19
7.1 Cleaning the filter ...............................19
7.2 Cleaning the housing .........................19
7.3 Storage .............................................. 19
8. What to do if there are problems? .......20
9. Disposal ..................................................20
10. Replacement parts and wearing parts 20
11. Technical data ........................................ 21
1. Getting to know your device
Humans spend a large proportion of their time indoors. The air indoors is often polluted with dust particles, pollen, animal hair, odours, harmful gases as well as various bacteria and viruses. The LR 300 air cleaner cleans the ambient air using a three-layered filter system and an in-built UV-C light.
The LR 300 air cleaner
Filters air with a combi filter (activated carbon filter against harmful gases and unpleasant odours,
HEPA filterE 12
Has an in-built UV-C light (to kill germs)
Operates quietly with three output levels
Has a timer function (two, four or eight hours)
Suitable for rooms up to 35 m² in size
Energy-saving
Switches o automatically when the housing cover is removed.
against particles such as bacteria, viruses, mites, pollen and fine dust)
Principle of air cleaning
1. The air cleaner's fan sucks in the contaminated air.
2. The pre-filter filters larger particles such as dust, dirt and hairs.
3. Next, the activated carbon filter filters formaldehyde, benzene and other poisonous gases and odours out of the ambient air.
4. Lastly, the HEPA filter filters out small particles such as pollen, bacteria or viruses.
5. The switchable UV-C light inside the housing tobacco smoke).
6. The cleaned air is emitted into the ambient air via the air outlet on top of the air cleaner.
The HEPA E 12 filter has a filter performance of ≥ 99.5%. That means that 99.5% of particles (e.g.bacteria, viruses and fine dust) can be filtered out.
eliminates germs and odours (caused by animals, cooking or
13
Page 3
Contaminated, unfiltered air can have the following eects:
Infections and respiratory diseases are more likely to occur
Damage to health through harmful gases
2. Intended use
This air cleaner is intended exclusively for cleaning the air indoors.
WARNING
If you suer from severe respiratory or lung disease, consult your doctor before using the air cleaner. This device must only be used for the purpose for which it was designed and in the manner specified in the instructions for use. Improper use can be dangerous. The manufacturer is not liable for damage resulting from improper or careless use.
3. Notes
Read the notes carefully! Non-observance of the following information may result in personal injury or material damage.
WARNING
Keep packaging material away from children to avoid danger of suocation.
Electric shock
WARNING
As with every electrical device, use this air cleaner carefully and cautiously, in order to avoid hazards due to electric shock.
• Therefore, observe the following instructions for use:
– do not operate the device at voltages other than those indicated on the device (the type plate is located
underneath the device) – never if it or its accessories show visible signs of damage – not during a thunderstorm
In the event of defects or operational faults, switch the device o immediately and disconnect it from themains socket. Do not pull on the mains cable or on the device to disconnect the plug from the socket. Never hold or carry the device by the mains cable. Keep the cables away from hot surfaces.
Always switch o the device before disconnecting it from the mains.
Never disconnect the mains plug with wet or damp hands.
Keep the device away from sources of heat as the housing could melt and trigger a fire.
Ensure that the openings of the device and the mains cable do not come into contact with water, steam or other liquids.
Do not use the device in close proximity to flammable or explosive gas mixtures.
Never reach for a device that has been submerged in water. Disconnect it from the mains plug immediately.
Do not use the device if it or its accessories are visibly damaged.
Repairs
WARNING
Only specialist personnel may perform repairs on electrical devices. Improper repairs may subject users to considerable danger. For repairs, please contact Customer Services or an authorised retailer.
Do not open the fan unit.
Risk of fire
WARNING
There is a risk of fire if the device is used improperly or these instructions for use are ignored. Therefore, observe the following instructions for using the air cleaner:
Never use underneath a cover, such as a blanket, pillow etc.
Never use near petrol or other highly flammable substances.
14
Page 4
Handling
IMPORTANT
The device must be switched o and disconnected from the mains after every use and before cleaning.
Do not place any objects in device openings or in rotating parts. Ensure that the moving parts can move freely at all times.
Do not place any objects on the device.
Do not expose the device to high temperatures.
Protect the device against sunlight and impacts and do not drop it.
Never shake the device.
Place the device on a firm, level and water-resistant surface.
4. Device description
3
2
1
8
6
7
1. Air outlet
2.
Combi filter (activated carbon filter/HEPA filter
E 12)
Activated carbon filter: To counter harmful gases and unpleasant smells HEPA filter E 12: Filters particles such as bacteria, viruses, mites, pollen and fine dust
3. Pre-filter
Filters coarse dust and dirt, such as hairs
4. Control panel 8. Air inlet
5. Housing cover
6. UV-C light
Eliminates cooking or tobacco smoke) inside the housing
7. Housing
4
5
germs and odours (caused by animals,
15
Page 5
Display and buttons
1
1 ON/OFF button
Switches the device on/o
2 AUTO button
Activates the automatic function (fan speed auto matically adapts to the ambient air quality and the LED is lit continuously). If the light below "Replace Filter" is flashing, change the filter. After changing the filter, hold down the AUTO button to reset the automatic counter for the filter change.
3 FAN SPEED button
The air cleaner has three fan speeds: (low),
(medium) and (high).
2
3
4 UV-C light button
Switches the UV-C light on/o
5 TIMER button
-
The air cleaner features a timer function that you can use to determine the number of hours the air cleaner should run for before it automatically switches itself o. The air cleaner has three timer periods: 2H (two hours), 4H (four hours) and 8H (eight hours).
4
5
5. Initial use
5.1 Removing the air cleaner
1. Open the cardboard packaging.
2. Remove the device from the top of the box without opening the film bag.
3. Now remove all plastic films. Remove the combi filter from the device (see "Filter change" section) and
take it out of the plastic film. Then re-insert the combi filter into the device.
4. Check the device, mains plug and cable for damage.
5.2 Setting up the air cleaner
1. Place the air cleaner on a firm, level surface to prevent vibrations and noise.
IMPORTANT
If you wish to reposition the air cleaner, only carry it by the handle on the rear of the device.
2. Set up the air cleaner in such a way that provides 30 cm clearance on all sides.
3. Make sure that the air inlet and air outlet are never blocked.
16
Page 6
6. Operation
6.1 Switching on the air cleaner
1. Always follow the instructions in chapter "5 Initial use".
2. Insert the mains plug into the socket. Ensure that the cable does not pose a trip hazard.
3. Press the ON/OFF button (
Note
When the air cleaner is used for the first time it is set to the middle fan speed.
6.2 Automatic function
The air cleaner has an automatic function. When the automatic function is switched on, the fan speed automatically adapts to the ambient air quality. This means that, the poorer the quality of the ambient air, the higher the fan speed automatically set by the air cleaner.
1.
To switch on the automatic function, press the AUTO button while the air cleaner is switched on ( ). As soon as the automatic function is active, a light goes on above the AUTO button.
2. Press the goes out.
AUTO button ( ) again to switch o the automatic function. The light above the AUTO button
Note
If the light above the AUTO button is flashing, you must replace the filter. To do this, follow the instructions in the "Filter change" section.
6.3 Fan speed
The air cleaner has three fan speeds: (low), (medium) and (high).
To switch between the individual fan speeds, press the fan speed button . The fan speed that is currently set lights up on the control panel.
6.4 UV-C light
The UV-C light eliminates germs contained in the air. Here the UV-C light activates titanium oxides that break down the foul-smelling odour molecules (caused by tobacco smoke, cooking smells or animals).
1.
To switch on the as the
UV-C light
2. Press the
UV-C light
is active, a light goes on above the UV-C button.
UV-C button
6.5 Timer function
The air cleaner features a timer function that you can use to determine the number of hours the air cleaner should run for before it automatically switches itself o. The air cleaner has three timer periods: 2H (twohours), 4H (four hours) and 8H (eight hours).
To switch between the individual timer periods, press the TIMER button currently set lights up on the control panel. The air cleaner will now automatically switch o after the set number of hours has passed.
To switch o the timer, repeatedly press the TIMER button ( ), until the light above the TIMER button goes out. The air cleaner now cleans continuously.
) to switch on the air cleaner.
, press the UV-C button on the air cleaner while it is switched on ( ). Assoon
( ) again to switch o the
UV-C light. The light above the UV-C button goes out.
( )
The TIMER period that is
17
Page 7
6.6 Filter change
The three-layered filter should be replaced with a new one after 4320 operating hours. After 4320 operating hours, a blue LED flashes above the AUTO button. To change the filter, proceed as follows:
2.
1.
1.
Press the ON/OFF button to switch o the air cleaner, and unplug it from the socket.
3.
Pull out the pre-filter. Now, to pull out the combi filter, pull carefully on the side tabs.
1.
2. Remove the housing cover as shown (magnetic fastening). Firstly detach the magnetic fastening at the bottom, and then at the top.
4.
Insert a new combi filter. To insert the combi filter correctly, align it with the side tabs as shown. Position the pre-filter above it.
2.
5.
Re-insert the housing cover as shown until yousee and hear it click into place (magnetic fastening). First attach the magnetic fastening at the top, and then at the bottom.
Insert the mains plug into the socket. Ensure that
6. the cable does not pose a trip hazard. Press and hold the AUTO button ( ) for five seconds. operating hours counter now resets to 0.
If you wish to change the combi filter at specific personal intervals (e.g. every six months), there is a sticker on the upper edge of the combi filter on which a date can be entered.
18
The
Page 8
7. Cleaning and storage
WARNING
Before cleaning, always ensure that the mains plug of the air cleaner has been properly disconnected.
7.1 Cleaning the filter
Regular cleaning of the filter (once a month) is a prerequisite for hygienic and fault-free operation.
Clean the three-layered filter using the brush attachment of a vacuum cleaner. To carry out a thorough clean, pull out the pre-filter and clean the activated carbon filter located behind it and the HEPA filter located at the rear, also using the brush attachment from a vacuum cleaner. Then replace the pre-filter on the HEPA filter.
The activated carbon filter is located below the pre-filter
Activated carbon filter
Front
HEPA filter E 12
Rear
IMPORTANT
The three-layered filter should be changed after 4320 operating hours (see "Filter change" section). The three-layered filter cannot be washed.
7.2 Cleaning the housing
Clean the housing of the air cleaner with a damp cloth (water or a mild cleaning solution). When cleaning, do not use any solvents or other aggressive or abrasive cleaning agents, as the surface may become damaged.
7.3 Storage
If you do not plan to use the device for a long period of time, we recommend that you clean it and store it in the original packaging in a dry environment, ensuring it is not weighed down by additional items.
19
Page 9
8. What to do if there are problems?
Problem Cause Solution
The air cleaner will not switch on
Insucient passage of air The filters are dirty
Air cleaner is very loud There is a foreign body in the air
The housing cover is not correct­ly installed.
The three-layered filter is not cor­rectly inserted.
The mains part plug is not plugged in.
The air intake/air outlet is blocked.
intake/air outlet. The filters are clogged.
The filters are not correctly in­serted.
The air cleaner is positioned on an uneven surface.
Ensure that the housing cover is correctly installed.
Ensure that the three-layered fil ter is correctly inserted.
Plug the mains part plug into asuitable socket.
Clean the filters (see "Mainte­nance and cleaning" section).
Ensure that the air intake/air out let is not blocked.
Remove the foreign body from the air intake/air outlet.
Clean the filters (see "Mainte­nance and cleaning" section).
Insert the filters correctly.
Position the air cleaner on a level surface.
-
-
9. Disposal
For environmental reasons, do not dispose of the device in the household waste at the end of its useful life. Dispose of the device at a suitable local collection or recycling point. Dispose of the device inaccordance with EC Directive – WEEE (Waste Electrical and Electronic Equipment). If you have any questions, please contact the local authorities responsible for waste disposal.
10. Replacement parts and wearing parts
Replacement parts and wearing parts are available from the corresponding service address (according to the service address list). Please state the corresponding order number.
Designation Item number and/or order number
Pre-filter, combi filter (HEPA + activated carbon) 660.12
20
Page 10
11. Technical data
Model LR 300 Mains voltage See type plate on the device Output 55 W Dimensions (L x W x H) 324 x 162 x 409 mm Weight when empty 4.5 kg UV light Wave length 254 nm; service life approx. 20,000 hours Suitable for rooms approx. 35 m Permissible operating conditions +5°C to +40°C, ≤ 90% relative humidity (non-condensing) Protection class
Protection class II /
2
21
Subject to errors and changes
Loading...