Beurer BM44 Service Manual

BM 44
D
Blutdruckmessgerät
Gebrauchsanweisung .......................................................... 2 – 14
G
Blood pressure monitor
Instructions for use ............................................................ 15 – 25
F
Tensiométre
Mode d’emploi .................................................................... 26 – 37
Tensiómetro
Instrucciones de uso .......................................................... 38 – 49
I
Misuratore di pressione
Istruzioni per l’uso .............................................................. 50 – 61
T
Bilgisayarli tansiyon ölçer
Kullanım kılavuzu ................................................................62– 72
Прибор для измерения кровяного давления
в плечевой артерии
Инструкция по применению ........................................... 73 – 86
Q
Ciśnieniomierz
Instrukcja obsługi ............................................................... 87 – 98
Electromagnetic Compatibility Information ........................ 99 – 102
0483
DEUTSCH
Inhalt
1. Kennenlernen ............................................................... 2
2. Wichtige Hinweise ........................................................ 3
4. Messung vorbereiten .................................................... 7
5. Blutdruck messen......................................................... 8
6. Fehlermeldung / Fehlerbehebung ................................ 11
7. Reinigung und Pflege ................................................. 12
8. Technische Angaben .................................................. 12
9. Netzteil ........................................................................ 13
10. Garantie .................................................................... 14
Sehr geehrte Kundin, sehr geehrter Kunde,
wir freuen uns, dass Sie sich für ein Produkt unseres Sorti­mentes entschieden haben. Unser Name steht für hoch­wertige und eingehend geprüfte Qualitätsprodukte aus den Bereichen Wärme, Gewicht, Blutdruck, Körpertemperatur, Puls, Sanfte Therapie, Massage und Luft. Bitte lesen Sie diese Gebrauchsanweisung aufmerksam durch, bewahren Sie sie für späteren Gebrauch auf, machen Sie sie anderen Benutzern zugänglich und beachten Sie die Hinweise.
Mit freundlicher Empfehlung Ihr Beurer-Team
1. Kennenlernen
Das Oberarm-Blutdruckmessgerät dient zur nichtinvasiven Messung und Überwachung arterieller Blutdruckwerte von erwachsenen Menschen. Sie können damit schnell und einfach Ihren Blutdruck mes­sen und den letzten Messwert anzeigen lassen. Bei eventuell vorhandenen Herzrhythmusstörungen werden Sie gewarnt. Bewahren Sie diese Gebrauchsanweisung für weitere Benutzung auf und machen Sie diese auch anderen Benut­zern zugänglich.
2
2. Wichtige Hinweise
Storage
RH ≤90%
Operating
RH ≤90%
Zeichenerklärung
In der Gebrauchsanweisung, auf der Verpackung und auf dem Typschild des Geräts und des Zubehörs werden fol­gende Symbole verwendet:
Vorsicht
Zulässige Lagerungstemperatur und -luft-
55°C
-20°C
10°C
feuchtigkeit
Zulässige Betriebstemperatur und -luft-
40°C
feuchtigkeit
Vor Nässe schützen
Hinweis Hinweis auf wichtige Informationen
Gebrauchsanweisung beachten
Anwendungsteil Typ BF
Gleichstrom Entsorgung gemäß Elektro- und Elektronik-
Altgeräte EG-Richtlinie – WEEE (Waste Electrical and Electronic Equipment)
Hersteller
SN
Seriennummer
Die CE-Kennzeichnung bescheinigt die Konformität mit den grundlegenden An­forderungen der Richtlinie 93/42/EEC für
0483
Medizinprodukte.
Hinweise zur Anwendung
• Um eine Vergleichbarkeit der Werte zu gewährleisten, mes­sen Sie Ihren Blutdruck immer zu gleichen Tageszeiten.
Ruhen Sie sich vor jeder Messung ca. 5 Minuten aus!
Wenn Sie mehrere Messungen an einer Person durchfüh-
ren möchten, warten Sie zwischen den einzelnen Messun­gen jeweils 5 Minuten.
Mindestens 30 Minuten vor der Messung sollten Sie nicht
essen, trinken, rauchen oder sich körperlich betätigen.
Wiederholen Sie die Messung im Falle zweifelhaft gemes-
sener Werte.
3
Die von Ihnen selbst ermittelten Messwerte können nur zu
Ihrer Information dienen – sie ersetzen keine ärztliche Un­tersuchung! Besprechen Sie Ihre Messwerte mit dem Arzt, begründen Sie daraus auf keinen Fall eigene medizinische Entscheidungen (z.B. Medikamente und deren Dosierun­gen)!
Verwenden Sie das Blutdruckmessgerät nicht bei Neuge-
borenen und Präeklampsie-Patientinnen. Vor Anwendung des Blutdruckmessgerätes in der Schwangerschaft emp­fehlen wir eine Abstimmung mit dem Arzt.
Erkrankungen des Herz-Kreislaufsystems können zu Fehl-
messungen bzw. zu Beeinträchtigungen der Messgenau­igkeit führen. Ebenso der Fall ist dies bei sehr niedrigem Blutdruck, Diabetes, Durchblutungs- und Rhythmusstö­rungen sowie bei Schüttelfrost oder Zittern.
Das Blutdruckmessgerät darf nicht im Zusammenhang mit
einem Hochfrequenz-Chirurgiegerät verwendet werden.
Verwenden Sie das Gerät nur bei Personen mit dem für
das Gerät angegebenen Umfangbereich des Oberarmes.
Beachten Sie, dass es während des Aufpumpens zu einer
Funktionsbeeinträchtigung des betroffenen Gliedmaßes kommen kann.
Die Blutzirkulation darf durch die Blutdruckmessung nicht
unnötig lange unterbunden werden. Bei einer Fehlfunktion des Gerätes nehmen Sie die Manschette vom Arm ab.
Vermeiden Sie das mechanische Einengen, Zusammen-
drücken oder Abknicken des Manschettenschlauches.
Verhindern Sie einen anhaltenden Druck in der Manschet-
te sowie häufige Messungen. Eine dadurch resultierende Beeinträchtigung des Blutflusses kann zu Verletzungen führen.
Achten Sie darauf, dass die Manschette nicht an einem
Arm angelegt wird, dessen Arterien oder Venen in medi­zinischer Behandlung sind, z.B. intravaskulärer Zugang bzw. eine intravaskuläre Therapie oder ein arteriovenöser (A-V-) Nebenschluss.
Legen Sie die Manschette nicht bei Personen an, die eine
Brustamputation hatten.
Legen Sie die Manschette nicht über Wunden an, da dies
zu weiteren Verletzungen führen kann.
Sie können das Blutdruckmessgerät mit Batterien oder mit
einem Netzteil betreiben. Beachten Sie, dass eine Daten­übertragung und Datenspeicherung nur möglich ist, wenn Ihr Blutdruckmessgerät Strom erhält. Sobald die Batterien verbraucht sind oder das Netzteil vom Stromnetz getrennt wird, verliert das Blutdruckmessgerät Datum und Uhrzeit.
Die Abschaltautomatik schaltet das Blutdruckmessgerät
zur Schonung der Batterien aus, wenn innerhalb 1 Minute keine Taste betätigt wird.
Das Gerät ist nur für den in dieser Gebrauchsanweisung
beschriebenen Zweck vorgesehen. Der Hersteller haftet nicht für Schäden, die durch unsachgemäßen oder fal­schen Gebrauch verursacht wurden.
4
Hinweise zur Aufbewahrung und Pflege
Das Blutdruckmessgerät besteht aus Präzisions- und
Elektronik-Bauteilen. Die Genauigkeit der Messwerte und Lebensdauer des Gerätes hängt ab vom sorgfältigen Um­gang:
– Schützen Sie das Gerät vor Stößen, Feuchtigkeit,
Schmutz, starken Temperaturschwankungen und direk-
ter Sonneneinstrahlung. – Lassen Sie das Gerät nicht fallen. – Benutzen Sie das Gerät nicht in der Nähe von starken
elektromagnetischen Feldern, halten Sie es fern von
Funkanlagen oder Mobiltelefonen.
Drücken Sie nicht auf die Start/Stopp-Taste , solange
die Manschette nicht angelegt ist.
Wir empfehlen die Batterien zu entfernen, falls das Gerät
über einen längeren Zeitraum nicht benutzt wird.
Hinweise zum Umgang mit Batterien
Wenn Flüssigkeit aus einer Batteriezelle mit Haut oder
Augen in Kontakt kommt, die betroffene Stelle mit Wasser auswaschen und ärztliche Hilfe aufsuchen.
Verschluckungsgefahr! Kleinkinder könnten Batte­rien verschlucken und daran ersticken. Daher Batterien für Kleinkinder unerreichbar aufbewahren!
Auf Polaritätskennzeichen Plus (+) und Minus (-) achten.
Wenn eine Batterie ausgelaufen ist, Schutzhandschuhe
anziehen und das Batteriefach mit einem trockenen Tuch reinigen.
Schützen Sie Batterien vor übermäßiger Wärme.
Explosionsgefahr! Keine Batterien ins Feuer werfen.
Batterien dürfen nicht geladen oder kurzgeschlossen wer-
den.
Bei längerer Nichtbenutzung des Geräts die Batterien aus
dem Batteriefach nehmen.
Verwenden Sie nur denselben oder einen gleichwertigen
Batterietyp.
Immer alle Batterien gleichzeitig auswechseln.
Keine Akkus verwenden!
Keine Batterien zerlegen, öffnen oder zerkleinern.
Hinweise zu Reparatur und Entsorgung
Batterien gehören nicht in den Hausmüll. Bitte entsorgen
Sie die verbrauchten Batterien an den dafür vorgesehenen Sammelstellen.
Öffnen Sie das Gerät nicht. Bei Nichtbeachtung erlischt
die Garantie.
Das Gerät darf nicht selbst repariert oder justiert werden.
Eine einwandfreie Funktion ist in diesem Fall nicht mehr gewährleistet.
Reparaturen dürfen nur vom Kundenservice oder autori-
sierten Händlern durchgeführt werden. Prüfen Sie jedoch
5
vor jeder Reklamation zuerst die Batterien und tauschen Sie diese gegebenenfalls aus.
Im Interesse des Umweltschutzes darf das Gerät
am Ende seiner Lebensdauer nicht mit dem Haus­müll entfernt werden. Die Entsorgung kann über entsprechende Sammelstellen in Ihrem Land erfolgen. Entsorgen Sie das Gerät gemäß der Elektro- und Elek­tronik-Altgeräte EG-Richtlinie – WEEE (Waste Electrical and Electronic Equipment). Bei Rückfragen wenden Sie sich an die für die Entsorgung zuständige kommunale Behörde.
3. Gerätebeschreibung / Anzeigen auf dem Display
1
2
1. Manschettenschlauch
2. Manschette
3. Manschettenstecker
6
3
12 11
10
9
SYS
mmHg
DIA
mmHg
PUL
/min
8 7
6
1. Anschluss für Netzteil
2. Systolischer Druck
3. Diastolischer Druck
4. Puls
5. Symbol Puls
6. Batteriefach
7. Start-/Stopp-Taste
8. Symbol Batteriewechselanzeige
9. Pfeil Luft ablassen
10. Arrhythmieerkennung
11. Anschluss für Manschettenstecker
12. Einstufung der Messergebnisse
4. Messung vorbereiten
Batterie einlegen
1
2
3
4
5
Entfernen Sie den Deckel
des Batteriefaches auf der Rückseite des Gerätes.
Legen Sie vier Batterien
vom Typ 1,5 V AA (Alkaline Type LR 06) ein.
Achten Sie unbedingt darauf, dass die Batterien entspre-
chend der Kennzeichnung mit korrekter Polung eingelegt werden. Verwenden Sie keine wiederaufladbaren Akkus.
Schließen Sie den Batteriefachdeckel wieder sorgfältig.
Wenn die Batteriewechselanzeige
dauerhaft erscheint ist keine Messung mehr möglich und Sie müssen alle Bat­terien erneuern.
Batterie Entsorgung
• Die verbrauchten, vollkommen entladenen Batterien müs-
sen Sie über speziell gekennzeichnete Sammelbehälter, Sondermüllannahmestellen oder über den Elektrohändler entsorgen. Sie sind gesetzlich dazu verpflichtet, die Bat­terien zu entsorgen.
7
• Diese Zeichen finden Sie auf schadstoffhaltigen Batterien:
Pb = Batterie enthält Blei, Cd = Batterie enthält Cadmium, Hg = Batterie enthält Quecksilber
Betrieb mit dem Netzteil
Sie können dieses Gerät auch mit einem Netzteil betreiben. Dazu dürfen keine Batterien im Batteriefach sein. Das Netz­teil ist unter der Bestellnummer 071.19 im Fachhandel oder bei der Serviceadresse erhältlich.
Das Blutdruckmessgerät darf ausschließlich nur mit dem
hier beschriebenen Netzteil betrieben werden, um eine mögliche Beschädigung des Blutdruckmessgerätes zu verhindern.
Stecken Sie das Netzteil in den dafür vorgesehenen An-
schluss auf der rechten Seite des Blutdruckmessgerätes. Das Netzteil darf nur an die auf dem Typschild angegebe­ne Netzspannung angeschlossen werden.
Schließen Sie danach den Netzstecker des Netzteils an
die Steckdose an.
Nach dem Gebrauch des Blutdruckmessgerätes trennen
Sie das Netzteil zuerst von der Steckdose und anschlie­ßend vom Blutdruckmessgerät. Sobald Sie das Netzteil ausstecken, verliert das Blutdruckmessgerät Datum und Uhrzeit. Die gespeicherten Messwerte bleiben jedoch erhalten.
5. Blutdruck messen
Bitte bringen Sie das Gerät vor der Messung auf Raum­temperatur.
Manschette anlegen
Legen Sie die Manschette am entblößten linken Oberarm an. Die Durchblutung des Arms darf nicht durch zu enge Kleidungsstücke oder Ähnliches eingeengt sein.
Die Manschette ist am Oberarm so zu platzieren, dass der untere Rand 2 – 3 cm über der Ellenbeuge und über der Arterie liegt. Der Schlauch weist zur Handflächenmitte.
Legen Sie die Manschette nun eng, aber nicht zu fest, um den Arm und befestigen Sie sie mit dem Klettverschluss. Die Manschette sitzt fest genug, wenn zwei Finger gerade so zwischen Manschette und Arm passen.
Führen Sie den Schlauch in die entsprechende Aufnahme an der Manschette ein.
8
Fixieren Sie die Manschette mit dem Klettverschluss so, dass sich das obere Ende der Anzeige ca.1cm unterhalb Ihres Handballens befindet.
Achtung: Das Gerät darf nur mit der Original-Manschette betrieben werden. Die Manschette ist für einen Armumfang von 22 bis 30 cm geeignet. Unter der Bestellnummer 162.795 ist eine größere Man­schette für Oberarmumfänge von 30 bis 42 cm beim Fach­handel oder bei der Serviceadresse erhältlich.
Richtige Körperhaltung einnehmen
Ruhen Sie sich vor jeder Messung ca. 5 Minuten aus!
Ansonsten kann es zu Abweichungen kommen.
Sie können die Messung im Sitzen oder im Liegen durch-
führen. Achten Sie in jedem Fall darauf, dass sich die Manschette in Herzhöhe befindet.
Sitzen Sie zur Blutdruckmessung bequem. Lehnen Sie
Rücken und Arme an. Kreuzen Sie die Beine nicht. Stellen Sie die Füße flach auf den Boden.
Um das Messergebnis nicht zu verfälschen ist es wichtig,
sich während der Messung ruhig zu verhalten und nicht zu sprechen.
Blutdruckmessung durchführen
Starten Sie das Blutdruckmessgerät mit der Taste Start/
Stopp
.
Vor der Messung wird kurz das letzte gespeicherte Mess-
ergebnis angezeigt. Sollte sich keine Messung im Spei­cher befinden, zeigt das Gerät jeweils den Wert
Die Manschette wird automatisch aufgepumpt. Der
an.
Manschetten-Luftdruck wird langsam abgelassen. Bei ei­ner bereits zu erkennenden Tendenz zu hohem Blutdruck wird nochmals nachgepumpt und der Manschettendruck nochmals erhöht. Sobald ein Puls zu erkennen ist, wird das Symbol Puls
Die Messergebnisse Systolischer Druck, Diastolischer
angezeigt.
Druck und Puls werden angezeigt.
Sie können die Messung jederzeit durch das Drücken der
Start-/Stopp-Taste
_ erscheint wenn die Messung nicht ordnungsgemäß
abbrechen.
durchgeführt werden konnte. Beachten Sie das Kapitel Fehlermeldung/Fehlerbehebung in dieser Gebrauchsanlei­tung und wiederholen Sie die Messung.
• Das Messergebnis wird automatisch abgespeichert.
• Zum Abschalten und Druckablassen drücken Sie erneut die Start-/Stopp-Taste
9
. Wenn Sie vergessen das Gerät
auszuschalten, schaltet sich das Gerät nach ca. 1 Minute automatisch ab.
Warten Sie vor einer erneuten Messung mindestens 5 Minu ten!
Ergebnisse beurteilen Herzrhythmusstörungen:
Dieses Gerät kann während der Messung eventuelle Störun­gen des Herzrhythmus identifizieren und weist gegebenen­falls nach der Messung mit dem Symbol
darauf hin. Dies kann ein Indikator für eine Arrhythmie sein. Arrhythmie ist eine Krankheit, bei der der Herzrhythmus aufgrund von Fehlern im bioelektrischen System, das den Herzschlag steuert, anormal ist. Die Symptome (ausgelassene oder vorzeitige Herzschläge, langsamer oder zu schneller Puls) können u.a. von Herzerkrankungen, Alter, körperlicher Ver­anlagung, Genussmitteln im Übermaß, Stress oder Mangel an Schlaf herrühren. Arrhythmie kann nur durch eine Unter­suchung bei Ihrem Arzt festgestellt werden. Wiederholen Sie die Messung, wenn das Symbol nach der Messung auf dem Display angezeigt wird. Bitte achten sie darauf, dass Sie sich 5 Minuten ausruhen und während der Messung nicht sprechen oder bewegen. Sollte das Symbol oft erscheinen, wenden Sie sich bitte an Ihren Arzt. Selbstdiagnose und -behandlung aufgrund der Mess­ergebnisse können gefährlich sein. Befolgen Sie unbedingt die Anweisungen Ihres Arztes.
10
Einstufung der Messergebnisse:
Die Messergebnisse lassen sich gemäß nachfolgender Tabelle einstufen und beurteilen. Diese Standardwerte dienen jedoch lediglich als allgemeine Richtlinie, da der individuelle Blutdruck bei verschiede­nen Personen und unterschiedlichen Altersgruppen usw. abweicht. Es ist wichtig, dass Sie Ihren Arzt in regelmäßigen Abstän­den zu Rate ziehen. Ihr Arzt teilt Ihnen Ihre individuellen Werte für einen normalen Blutdruck sowie den Wert mit, ab dem die Höhe des Blutdrucks als gefährlich einzustufen ist. Die Einstufung im Display und die Skala auf dem Gerät geben an, in welchem Bereich sich der ermittelte Blutdruck befindet. Sollte sich der Wert von Systole und Diastole in zwei unterschiedlichen Bereichen befinden (z.B. Systole im Bereich „Hoch Normal“ und Diastole im Bereich „Normal“) dann zeigt Ihnen die grafische Einteilung auf dem Gerät immer den höheren Bereich an, im beschriebenen Beispiel „Hoch Normal“.
Bereich der Blutdruckwerte
Stufe 3: starke Hypertonie
Stufe 2: mittlere Hypertonie
Stufe 1: leichte Hypertonie
Hoch normal 130 – 139 85 – 89
Normal 120 – 129 80 – 84 Selbstkontrolle Optimal < 120 < 80 Selbstkontrolle
Quelle: WHO, 1999 (World Health Organization)
Systole
(in mmHg)
≥ 180 ≥ 110 einen Arzt aufsuchen
160 – 179 100 – 109 einen Arzt aufsuchen
140 – 159 90 – 99
Diastole
(in mmHg)
Maßnahme
regelmäßige Kont rolle beim Arzt
regelmäßige Kont rolle beim Arzt
-
-
6. Fehlermeldung / Fehlerbehebung
Bei Fehlern erscheint auf dem Display die Fehlermeldung _. Fehlermeldungen können auftreten, wenn
• der systolische oder diastolische Druck nicht gemessen
werden konnte (
• der systolische oder diastolische Druck außerhalb des
Messbereichs liegt (
• die Manschette zu stark bzw. zu schwach angelegt ist (
bzw.
• der Aufpumpdruck höher als 300 mmHg ist (
im Display),
bzw.
erscheint im Display),
Hi“ bzw. „Lo
erscheint im Display),
erscheint im Display),
erscheint
• das Aufpumpen länger als 160 Sekunden dauert ( scheint im Display),
• ein System- oder Gerätefehler vorliegt oder
erscheint im Display),
• die Batterien fast verbraucht sind
( , ,
.
Wiederholen Sie in diesen Fällen die Messung. Achten Sie darauf, dass Sie sich nicht bewegen oder reden. Setzen Sie gegebenenfalls die Batterien neu ein oder erset­zen Sie diese.
Technischer Alarm – Beschreibung
Sollte der gemessene Blutdruck (systolisch oder diastolisch) außerhalb der im Abschnitt Technische Angaben angege­benen Grenzen liegen, erscheint auf dem Display der tech­nische Alarm in Form der Anzeige „Hi“ bzw. „Lo“. In diesem Fall sollten Sie einen Arzt aufsuchen bzw. die Richtigkeit Ihrer Bedienvorgänge überprüfen. Die Grenzwerte für den technischen Alarm sind ab Werk fest eingestellt und können nicht angepasst oder deaktiviert werden. Diesen Alarmgrenzwerten wird im Rahmen der Norm IEC 60601-1-8 untergeordnete Priorität beigemessen. Der technische Alarm ist ein nicht selbsthaltender Alarm und muss nicht zurückgesetzt werden. Das auf dem Display ange­zeigte Signal verschwindet nach rund 8 Sekunden automatisch.
11
er-
7. Reinigung und Pflege
• Reinigen Sie Gerät und Manschette vorsichtig nur mit ei­nem leicht angefeuchteten Tuch.
• Verwenden Sie keine Reinigungs- oder Lösungsmittel.
• Sie dürfen das Gerät auf keinen Fall unter Wasser halten, da sonst Flüssigkeit eindringen kann und das Gerät beschädigt.
• Stellen Sie keine schweren Gegenstände auf das Gerät.
8. Technische Angaben
Modell-Nr. BM 44 Messmethode Oszillometrisch, nicht invasive Blutdruck-
Messbereich Manschettendruck 0 – 300 mmHg,
Genauigkeit der Anzeige
Messunsicher­heit
Abmessungen L 94 mm x B 122 mm x H 53 mm Gewicht Ungefähr 230 g (ohne Batterien)
messung am Oberarm
systolisch 60 – 260 mmHg, diastolisch 40 –199 mmHg, Puls 40 –180 Schläge /Minute
systolisch ± 3 mmHg, diastolisch ± 3 mmHg, Puls ± 5 % des angezeigten Wertes
max. zulässige Standardabweichung ge­mäß klinischer Prüfung: systolisch 8 mmHg / diastolisch 8 mmHg
Manschetten­größe
Zul. Betriebs­bedingungen
Zul. Aufbewah­rungsbedingun­gen
Stromversorgung Batterie-Lebens-
dauer Zubehör Gebrauchsanweisung, 4 x 1,5 V AA Batte-
Klassifikation
Änderungen der technischen Angaben ohne Benachrichti­gung sind aus Aktualisierungsgründen vorbehalten.
Dieses Gerät entspricht der europäischen Norm EN60601-
1-2 und unterliegt besonderen Vorsichtsmaßnahmen hin­sichtlich der elektromagnetischen Verträglichkeit. Bitte be­achten Sie dabei, dass tragbare und mobile HF-Kommu­nikationseinrichtungen dieses Gerät beeinflussen können. Genauere Angaben können Sie unter der angegebenen Kundenservice-Adresse anfordern oder am Ende der Ge­brauchsanweisung nachlesen.
12
22 bis 30 cm
+ 10 °C bis + 40 °C, ≤90 % relative Luft­feuchte (nicht kondensierend)
- 20 °C bis + 55 °C, ≤90 % relative Luft­feuchte, 800 –1050 hPa Umgebungsdruck
4 x 1,5 V Für ca. 600 Messungen, je nach Höhe
des Blutdrucks bzw. Aufpumpdruck
rien, Aufbewahrungstasche Interne Versorgung, IPX0, kein AP oder
APG, Dauerbetrieb, Anwendungsteil Typ BF
AA Batterien
Das Gerät entspricht der EU-Richtlinie für Medizinpro-
dukte 93/42/EEC, dem Medizinproduktegesetz und den Normen EN1060-1 (nicht invasive Blutdruckmessgerä­te Teil 1: Allgemeine Anforderungen), EN1060-3 (nicht invasive Blutdruckmessgeräte Teil 3: Ergänzende Anfor­derungen für elektromechanische Blutdruckmesssyste­me) und IEC80601-2-30 (Medizinische elektrische Geräte Teil 2 – 30: Besondere Festlegungen für die Sicherheit einschließlich der wesentlichen Leistungsmerkmale von automatisierten nicht invasiven Blutdruckmessgeräten).
Die Genauigkeit dieses Blutdruckmessgerätes wurde
sorgfältig geprüft und wurde im Hinblick auf eine lange nutzbare Lebensdauer entwickelt. Bei Verwendung des Gerätes in der Heilkunde sind Messtechnische Kontrollen mit geeigneten Mitteln durchzuführen. Genaue Angaben zur Überprüfung der Genauigkeit können unter der Ser­vice-adresse angefragt werden.
9. Netzteil
Modell-Nr. FW 7575M/EU/6/06 Eingang 100 – 240 V, 50 – 60 Hz Ausgang 6 V DC, 600 mA, nur in Verbindung mit
Hersteller Friwo Gerätebau GmbH
Beurer Blutdruckmessgeräten
Schutz
Gehäuse und Schutzabdeckung
13
Das Gerät ist doppelt schutzisoliert und verfügt über eine primärseitige Tempera tursicherung, die das Gerät im Fehlerfall vom Netz trennt. Stellen Sie sicher, dass Sie die Batterien aus dem Batteriefach entnommen ha ben, bevor Sie das Netzteil benutzen.
Schutzisoliert / Schutzklasse 2
Polarität des Gleichspannungsan­schlusses
Das Netzteilgehäuse schützt vor Berüh­rung von Teilen, die unter Strom stehen bzw. stehen können (Finger, Nadel, Prüfhaken). Der Anwender darf nicht gleichzeitig den Patienten und den Ausgangsste­cker des DC-Netzteil berühren.
-
-
10. Garantie
Wir leisten 3 Jahre Garantie ab Kaufdatum für Material- und Fabrikationsfehler des Produktes. Die Garantie gilt nicht:
• Im Falle von Schäden, die auf unsachgemäßer Bedienung
beruhen.
• Für Verschleißteile.
• Bei Eigenverschulden des Kunden.
• Sobald das Gerät durch eine nicht autorisierte Werkstatt
geönet wurde. Die gesetzlichen Gewährleistungen des Kunden bleiben durch die Garantie unberührt. Für Geltendmachung eines Garantiefalles innerhalb der Garantiezeit ist durch den Kunden der Nachweis des Kaufes zu führen. Die Garantie ist innerhalb eines Zeitraumes von 3 Jahren ab Kaufdatum gegenüber der Beurer GmbH, Ulm (Germany) geltend zu machen.
Bitte wenden Sie sich im Falle von Reklamationen an unseren Service unter folgendem Kontakt: Service Hotline:
Tel.: +49 (0) 731 / 39 89-144 E-Mail: kd@beurer.de www.beurer.com
Fordern wir Sie zur Übersendung des defekten Produk­tes auf, ist das Produkt an folgende Adresse zu senden:
Beurer GmbH Servicecenter Lessingstraße 10 b 89231 Neu-Ulm Germany
14
Irrtum und Änderungen vorbehalten
ENGLISH
Contents
1. Getting to know your instrument ................................ 15
2. Important information ................................................. 16
3. Unit description / Icons in the display ......................... 19
4. Prepare measurement ................................................ 20
5. Measuring blood pressure .......................................... 21
6. Error messages / trouble-shooting .............................. 23
7. Cleaning and care ...................................................... 24
8. Technical details ......................................................... 24
9. Mains part................................................................... 25
Dear Customer,
Thank you for choosing one of our products. Our name stands for high-quality, thoroughly tested products for the applications in the areas of heat, weight, blood pressure, body temperature, pulse, gentle therapy, massage and air. Please read these instructions for use carefully and keep them for later use, be sure to make them accessible to other users and observe the information they contain.
Best regards, Your Beurer Team
1. Getting to know your instrument
The upper arm blood pressure monitor is used for non­invasive measurement and monitoring of adults‘ arterial blood pressure. This allows you to quickly and easily measure your blood pressure and to display the last recorded measurement. A warning is issued for anyone suffering from cardiac ar­rhythmia. The recorded values are classified and evaluated graphi­cally. Store these instructions for use for future reference and make them accessible to other users.
15
2. Important information
Storage
RH ≤90%
Operating
RH ≤90%
Signs and symbols
The following symbols are used in these instructions for use, on the packaging and on the type plate for the device and accessories:
Caution
Permissible storage temperature and hu-
55°C
-20°C
10°C
midity
Permissible operating temperature and
40°C
humidity
Keep dry
Note Note on important information
Follow instructions for use
Type BF applied part
Direct current Disposal in accordance with EC Directive
– WEEE (Waste Electrical and Electronic Equipment).
Manufacturer
SN
Serial number
The CE labelling certifies that the product complies with the essential requirements of Directive 93/42/EEC on medical prod-
0483
ucts.
Advice on use
In order to ensure comparable values, always measure
your blood pressure at the same time of day.
Before every measurement, relax for about five minutes.
If you want to perform several measurements on the same
person, wait five minutes between each measurement.
Do not take a measurement within 30 minutes after eating,
drinking, smoking or exercising.
Repeat the measurement if you are unsure of the meas-
ured value.
16
The measurements taken by you are for your information
only – they are not a substitute for a medical examination! Discuss the measurements with your doctor, and never base any medical decisions on them (e.g. medicines and their administration)!
Do not use the blood pressure monitor on newborns or
patients with preeclampsia. We recommend consulting a doctor before using the blood pressure monitor during pregnancy.
Cardiovascular diseases may lead to incorrect measure-
ments or have a detrimental effect on measurement ac­curacy. The same also applies to very low blood pressure, diabetes, circulatory disorders and arrhythmias as well as chills or shaking.
The blood pressure monitor must not be used in connec-
tion with a high-frequency surgical unit.
Only use the device on people who have the specified up-
per arm measurement for the device.
Please note that when inflating, the functions of the limb
in question may be impaired.
During the blood pressure measurement, blood circulation
must not be stopped for an unnecessarily long time. If the device malfunctions, remove the cuff from the arm.
Avoid any mechanical restriction, compression or bending
of the cuff line.
Do not allow sustained pressure in the cuff or frequent
measurements. The resulting restriction of the blood flow may cause injury.
Ensure that the cuff is not placed on an arm in which the
arteries or veins are undergoing medical treatment, e.g. intravascular access or therapy, or an arteriovenous (AV) shunt.
Do not use the cuff on people who have undergone a
mastectomy.
Do not place the cuff over wounds as this may cause fur-
ther injury.
• You can either use the blood pressure monitor with batter­ies or with a mains part. Please note that data transfer and data storage is only possible when your blood pressure monitor is supplied with power. As soon as the batteries are empty or the mains part is disconnected from the power supply, the blood pressure monitor loses the date and time.
To conserve the batteries, the monitor switches off auto-
matically if no buttons are pressed for one minute.
The device is only intended for the purpose described in
these instructions for use. The manufacturer is not liable for damage resulting from improper or careless use.
Storage and Care
The blood pressure monitor is made up of precision elec-
tronic components. Accuracy of readings and the instru­ment’s service life depend on careful handling.
17
– You should protect the device from impact, moisture,
dirt, major temperature fluctuations and direct exposure
to the sun’s rays. – Never drop the device. – Do not use near strong electromagnetic fields, i.e. keep
it away from any radio systems and mobile phones.
Do not press the start/stop button before the cuff is
placed on.
We advise you to remove the batteries if the device is not
going to be used for a longer period of time.
Notes on handling batteries
• If your skin or eyes come into contact with battery fluid,
flush out the affected areas with water and seek medical assistance.
Choking hazard! Small children may swallow and choke on batteries. Store the batteries out of the reach of small children.
Observe the plus (+) and minus (-) polarity signs.
If a battery has leaked, put on protective gloves and clean
the battery compartment with a dry cloth.
Protect the batteries from excessive heat.
Risk of explosion! Never throw batteries into a fire.
Do not charge or short-circuit batteries.
If the device is not to be used for a long period, take the
batteries out of the battery compartment.
Use identical or equivalent battery types only.
Always replace all batteries at the same time.
Do not use rechargeable batteries.
Do not disassemble, split or crush the batteries.
Repair and disposal
Batteries do not belong in domestic refuse. Used batteries
should be disposed of at the collection points provided.
Never open the instrument. If these instructions are not
heeded, the warranty will be null and void.
• Never attempt to repair the instrument or adjust it yourself. We can no longer guarantee perfect functioning if you do.
• Repairs may only be performed by Customer Service or au­thorized dealers. However, always check the batteries and replace them if necessary prior to making any complaint.
For environmental reasons, do not dispose of
the device in the household waste at the end of its useful life. Dispose of the device at a suitable local collection or recycling point. Dispose of the device in accordance with EC Directive – WEEE (Waste Electrical and Electronic Equipment). If you have any questions, please contact the local authorities responsible for waste disposal.
18
3. Unit description / Icons in the display
1
2
1. Cuff tube
2. Cuff
3. Cuff connector
3
12 11
10
9
8 7
6
1. Mains part port
2. Systolic pressure
3. Diastolic pressure
4. Pulse
5. Pulse symbol
6. Battery compartment
7. Start-/stop-button
8. Battery replacement symbol
9. Deflate arrow
10. Arrhythmia recognition
11. Cuff connector port
12. Classification of measurements
19
SYS
mmHg
DIA
mmHg
PUL
/min
1
2
3
4
5
4. Prepare measurement
Inserting battery
Remove the battery cover
from the back of the moni­tor.
Insert four 1.5 V AA (alkaline
type LR 06) batteries. Make absolutely sure that you insert them with the correct polarity as marked. Never use rechargeable batteries.
Replace the battery cover carefully.
If the battery change urement is no longer possible and you must replace all the batteries.
Battery disposal
• The empty, completely flat batteries must be disposed of through specially designated collection boxes, recycling points or electronics retailers. You are legally required to dispose of the batteries.
• The codes below are printed on batteries containing harmful substances:
Pb = Battery contains lead, Cd = Battery contains cadmium, Hg = Battery contains mercury
is continuously illuminated, meas-
Operation with the mains part
You can also operate this device with a mains part. When doing so, there must not be any batteries in the bat­tery compartment. The mains part can be obtained from specialist retailers or from the service address using order number 071.19.
To prevent possible damage to the device, the blood
pressure monitor must only be used with the mains part described here.
Insert the mains part into the connection provided for this
purpose on the right-hand side of the blood pressure mo­nitor. The mains part must only be connected to the mains voltage that is specified on the type plate.
Then insert the mains plug of the mains part into the
mains socket.
• After using the blood pressure monitor, unplug the mains part from the mains socket first and then disconnect it from the blood pressure monitor. As soon as you unplug the mains part, the blood pressure monitor loses the date and time setting but the saved measurements are retained.
5. Measuring blood pressure
Please ensure the device is at room temperature before measuring.
20
Positioning cuff
Fit the cuff round your bare left upper arm. Blood circulation in the arm should not be restricted by tight clothing or other objects.
The cuff should be placed on the upper arm so that the lower edge is 2 to 3 cm above the bend of the elbow and above the artery. The tube should be in line with the centre of the palm.
Important: The instrument should only be operated with the original cuff. The cuff is suitable for an arm circumference of 22 to 30 cm. A larger cuff for upper arm circumferences from 30 to 42 cm is available from retailers or the service address under order no. 162.795.
Correct posture
Now place the free end of the cuff snugly, but not too tightly, around the arm, and fix it with the hook and loop fastener. The cuff should be fitted tight enough to al­low just two fingers to fit beneath the cuff. Insert the cuff tubing into the socket for the cuff attachment.
Fasten the cuff with the hook and loop fastener so that the upper edge of the monitor is positioned approx. 1 cm below the ball of your thumb.
Rest for approx. 5 minutes before each measurement.
Otherwise there may be divergences.
You can perform the measurement either sitting or lying
down. Always make sure that the cuff is on a level with your heart.
To carry out a blood pressure measurement, make sure
you are sitting comfortably with your arms and back lean­ing on something. Do not cross your legs. Place your feet flat on the ground.
In order not to distort the result, it is important to keep still
during the measurement and not talk.
21
Measuring blood pressure
Switch on the blood pressure monitor with the start/stop
button
Before the measurement, the last saved test result is brief-
.
ly displayed. If there is no measurement in the memory, the instrument always displays the value
The cuff automatically inflates. Cuff air pressure is re-
.
leased slowly.
If a tendency towards high blood pressure is already
detectable, the cuff is pumped up again and cuff pressure increased further. As soon as a heart rate is detected, the heart rate symbol
Heart rate, systolic and diastolic blood pressure are dis-
is displayed.
played.
You can interrupt measurement at any time by pressing
the start/stop button
_ appears if it has not been possible to perform the
.
measurement properly. Observe the section in these in­structions on error messages/troubleshooting and repeat the measurement.
The test result is saved automatically.
To switch off and release the pressure, press the start/
stop button
again. If you forget to switch off the device,
it switches off automatically after approx. 1 minute.
Wait at least 5 minutes before taking another measurement!
Evaluating results Cardiac arrhythmia:
This instrument can identify possible cardiac arrhythmia dis­orders during measurement and if necessary indicates the measurement with the flashing icon
. This may be an indicator for arrhythmia. Arrhythmia is a condition where the heart rhythm is abnormal as a result of defects in the bioelectrical system controlling the heart beat. The symptoms (omitted or premature heart beats, slow or excessively fast heart rate) may be caused, among other things, by heart disease, age, physical predisposition, exces sive use of stimulants, stress or lack of sleep. Arrhythmia can only be ascertained through examination by your doctor. Repeat the measurement if the flashing icon
is dis­played after the measurement. Please note that you should rest for 5 minutes between measurements and not talk or move during the measurement. If the icon
appears often, please contact your doctor. Any self-diagnosis and treatment based on the test results may be dangerous. It is vital to follow your doctor’s instructions.
Classification of measurements:
The measurements can be classified and evaluated in accordance with the following table. However, these standard values serve only as a general gui­deline, as the individual blood pressure varies in different people and different age groups etc.
22
-
It is important to consult your doctor regularly for advice. Your doctor will tell you your individual values for normal blood pressure as well as the value above which your blood pressure is classified as dangerous. The classification on the display and the scale on the unit show which category the recorded blood pressure values fall into. If the values of systole and diastole fall into two dif­ferent categories (e.g. systole in the ‚High normal‘ category and diastole in the ‚Normal‘ category), the graphical classi­fication on the device always shows the higher category; for the example given this would be ‚High normal‘.
Blood pressure value category
Setting 3: severe hyper tension
Setting 2: moderate hyper tension
Setting 1: mild hypertension
High normal 130 – 139 85 – 89
Normal 120 – 129 80 – 84 self-monitoring Optimal < 120 < 80 self-monitoring
Source: WHO, 1999 (World Health Organization)
Systole
(in mmHg)
≥ 180 ≥ 110 seek medical attention
-
160 – 179 100 – 109 seek medical attention
-
140 – 159 90 – 99
Diastole
(in mmHg)
Action
regular monitoring by doctor
regular monitoring by doctor
23
6. Error messages / trouble-shooting
In case of faults, the _ message appears in the display. Error messages may appear if:
systolic or diastolic pressure could not be measured (
or
appears on the display)
systolic or diastolic pressure was outside the measure-
ment range (“Hi” or “Lo” appears on the display)
the cuff is fastened too tightly or loosely ( or ap-
pears on the display)
the pump pressure is higher than 300 mmHg ( ap-
pears on the display)
pumping up takes longer than 160 seconds ( appears
on the display)
there is a system or device error ( , , or
appears on the display)
the batteries are almost empty .
In such cases, repeat the measurement. Ensure you do not move or speak. If necessary, re-insert or replace the batteries.
Technical alarm – description
Should the recorded blood pressure (systolic or diastolic) lie outside the limits specified in the section “Technical specifica tions”, the technical alarm will appear on the display indicating either “Hi” or “Lo”. In such cases, you should seek medical as sistance and check the accuracy of your procedure.
-
-
The limit values for the technical alarm are factory set and can­not be adjusted or deactivated. These alarm limit values are accorded second priority under the standard IEC 60601-1-8. The technical alarm is a non-locking alarm and must not be reset. The signal shown on the display will disappear automati cally after about 8 seconds.
7. Cleaning and care
Clean your device and cuff carefully only with a slightly
moistened cloth.
Do not use any detergents or solvents.
Never hold the instrument under water as otherwise liquid
can penetrate and damage the instrument.
Never place any heavy objects on the instrument.
8. Technical details
Model no. BM 44 Measurement
method Measurement
range
Oscillometric, non-invasive blood pres­sure measurement on the upper arm
Cuff pressure 0 – 300 mmHg, systolic 60 – 260 mmHg, diastolic 40 –199 mmHg, Pulse 40 –180 beats/minute
Display accuracy Systolic ± 3 mmHg,
Measurement
­ inaccuracy
Dimensions L 94 mm x W 122 mm x H 53 mm Weight Approx. 230 g (without batteries) Cuff size 22 to 30 cm Permissible oper-
ating conditions Permissible stor-
age conditions Power supply Battery life For approx. 600 measurements, depend-
Accessories Instruction for use, 4 x 1.5 V AA batteries,
Classification Internal supply, IPX0, no AP or APG,
24
diastolic ± 3 mmHg, pulse ± 5 % of the value shown
Max. permissible standard deviation according to clinical testing: systolic 8 mmHg /diastolic 8 mmHg
+ 10 °C to + 40 °C, ≤90 % relative air humidity (non-condensing)
- 20 °C to + 55 °C, ≤90 % relative air humidity, 800 –1050 hPa ambient pressure
4 x 1,5 V
ing on the blood pressure level and/or pump pressure
storage pouch
continuous operation, type BF applied part
AA batteries
Technical information is subject to change without notifica­tion to allow for updates.
This unit is in line with European Standard EN 60601-1-2
and is subject to particular precautions with regard to electromagnetic compatibility (EMC). Please note that portable and mobile HF communication systems may in­terfere with this unit. More details can be requested from the stated Customer Service address or found at the end of the instructions for use.
This device is in line with the EU Medical Devices Direc-
tive 93/42/EEC, the “Medizinproduktegesetz” (German Medical Devices Act) and the standards EN1060-1 (non-invasive sphygmomanometers, Part 1: General requirements), EN1060-3 (non-invasive sphygmoma­nometers, Part 3: Supplementary requirements for electro-mechanical blood pressure measuring systems) and IEC 80601-2-30 (Medical electrical equipment – Part 2 – 30: Particular requirements for the safety and essential performance of automated non-invasive blood pressure monitors).
The accuracy of this blood pressure monitor has been
carefully checked and developed with regard to a long useful life. If using the device for commercial medical pur­poses, it must be regularly tested for accuracy by appro­priate means. Precise instructions for checking accuracy may be requested from the service address.
9. Mains part
Model no. FW 7575M/EU/6/06 Input 100 – 240 V, 50 – 60 Hz Output 6 V DC, 600 mA, in connection with Beurer
Supplier Friwo Gerätebau GmbH Protection This device is double insulated and pro-
Enclosures and Protective Covers
25
blood pressure monitor
tected against short circuit and overload by a primary thermal fuse. Make sure to take the batteries out of the compartment before using the mains part.
double insulated / equipment class 2
Polarity of the the DC voltage connection Equipment enclosed to protect against
contact with live parts, and with parts which can become live (finger, pin, hook test). The operator shall not contact the patient and the output plug of AC mains part simul­taneously.
Subject to errors and changes
FRANÇAIS
Sommaire
1. Premières expériences ............................................... 26
2. Remarques importantes ............................................. 27
3. Description de l´appareil / Affichages à l´écran ............ 30
4. Préparation à la mesure ..............................................31
5. Mesure de la tension artérielle .................................... 32
6. Message d’erreur / suppression des erreurs ............... 35
7. Nettoyage et entretien ................................................ 36
8. Données techniques ................................................... 36
9. Adaptateur .................................................................. 37
Chère cliente, cher client,
Nous sommes heureux que vous ayez choisi un produit de notre assortiment. Notre nom est synonyme de produits de qualité haut de gamme ayant subi des vérifications appro­fondies, ils trouvent leur application dans le domaine de la chaleur, du contrôle du poids, de la pression artérielle, de la mesure de température du corps et du pouls, des thérapies douces, des massages et de l’air. Lisez attentivement ce mode d’emploi, conservez-le pour un usage ultérieur, mettez-le à la disposition des autres utili­sateurs et suivez les consignes.
Avec nos sentiments dévoués Beurer et son équipe
26
1. Premières expériences
Le lecteur de tension artérielle au bras sert à la mesure non invasive et au contrôle de la tension artérielle chez l’adulte. Vous pouvez mesurer rapidement et simplement votre pres­sion artérielle et afficher la dernière valeur mesurée. L’appareil vous prévient en cas d’arythmie cardiaque éven­tuelle. Les valeurs calculées sont classées et évaluées sous forme graphique. Conservez ce mode d’emploi pour un usage ultérieur et mettez-le également à la disposition des autres utilisateurs.
2. Remarques importantes
Storage
RH ≤90%
Operating
RH ≤90%
Symboles utilisés
Les symboles suivants sont utilisés dans le mode d’emploi, sur l’emballage et sur la plaque signalétique de l’appareil et des accessoires:
Attention
Température et taux d'humidité de stoc-
55°C
-20°C
10°C
kage admissibles
Température et taux d'humidité d'utilisa-
40°C
tion admissibles
Protéger contre l’humidité
Remarque Ce symbole indique des informations importantes
Respectez les consignes du mode d’em­ploi
Appareil de type BF
Courant continu Élimination conformément à la directive
européenne WEEE (Waste Electrical and Electronic Equipment) relative aux déchets d’équipements électriques et électroniques
Fabricant
SN
Numéro de série
Le sigle CE atteste de la conformité aux exi­gences fondamentales de la directive 93/42/
0483
EEC relative aux dispositifs médicaux.
Remarques relatives à l’utilisation
Mesurez toujours votre tension au même moment de la
journée afin que les valeurs soient comparables.
Avant toute mesure, reposez-vous environ 5minutes!
Lorsque vous devez effectuer plusieurs mesures sur une
personne, patientez à chaque fois 5minutes entre chaque mesure.
Évitez de manger, boire, fumer ou d’exercer des activités
physiques pendant au moins 30minutes avant la mesure.
Effectuez une nouvelle mesure si vous avez un doute sur
les valeurs mesurées.
27
Les mesures que vous avez établies servent juste à vous
tenir informé de votre état- elles ne remplacent pas un examen médical! Parlez-en avec votre médecin, vous ne devez prendre aucune décision d’ordre médical sur la base de ces seules mesures (par ex. choix de médica­ments et de leurs dosages)!
N’utilisez pas le tensiomètre sur des nouveaux-nés et les
patientes atteintes de pré-éclampsie. Nous recomman­dons de consulter le médecin avant d’utiliser le tensio­mètre pendant la grossesse.
Les maladies cardio-vasculaires peuvent entraîner des
erreurs de mesure, plus précisément des mesures impré­cises. Ce problème se pose aussi en cas de tension très basse, de diabète, de troubles de la circulation et du rythme cardiaque et de frissons de fièvre ou de tremble­ments.
Le tensiomètre ne doit pas être utilisé parallèlement à un
appareil chirurgical haute fréquence.
Utilisez uniquement l’appareil sur des personnes dont le
périmètre du bras correspond à celui indiqué pour l’appa­reil.
• Veuillez noter que la fonction du membre concerné peut être entravée lors du gonflage.
• Il ne faut pas bloquer la circulation sanguine plus longtemps que nécessaire au cours de la prise de tension. Si l’appareil ne fonctionne pas bien, retirez le brassard du bras.
Évitez de presser, d’aplatir ou de plier le tuyau du bras-
sard en le manipulant.
Évitez des mesures trop fréquentes ou une pression conti-
nue du brassard. Elles entraînent une réduction de la cir­culation sanguine et constituent un risque de blessure.
Veillez à ne pas placer le brassard sur un bras, dont les
artères ou les veines sont soumises à un traitement médi­cal, par exemple en présence d’un dispositif d’accès intra­vasculaire destiné à un traitement intravasculaire ou en cas de shunt artérioveineux.
N’utilisez pas le brassard sur des personnes qui ont subi
une mastectomie.
Ne placez pas le brassard sur des plaies, son utilisation
peut les aggraver.
Vous pouvez utiliser le tensiomètre avec des piles ou un
adaptateur secteur. Notez que la transmission et l’enre­gistrement des données n’est possible que si votre tensio­mètre est alimenté. Dès que les piles sont usées ou que l’adaptateur secteur est débranché, le tensiomètre perd la date et l’heure configurées.
L’arrêt automatique permet de faire passer le tensiomètre
en mode économie d’énergie lorsqu’aucune touche n’est utilisée pendant 1minute.
L’appareil est conçu pour l’utilisation décrite dans ce
mode d’emploi. Le fabricant ne peut être tenu pour res­ponsable des dommages causés par une utilisation inap­propriée ou non conforme.
28
Remarques relatives à la conservation et à
l’entretien
L’appareil de mesure de la tension artérielle est constitué
de pièces électroniques, de grande précision. L’appareil doit être conservé dans un environnement approprié afin de garantir la précision des valeurs et d’optimiser la durée de vie du produit:
– Protégez l’appareil des chocs et conservez-le à l’abri de
l’humidité, de la poussière, des variations thermiques et
d’une exposition directe au soleil. – Ne laissez pas tomber l’appareil. – N’utilisez pas l’appareil à proximité de forts champs
électromagnétique. Eloignez-le des radios ou des télé-
phones mobiles.
N’appuyez pas sur la touche Marche/Arrêt tant que la
manchette n’est pas montée.
Nous recommandons de retirer les piles si l’appareil n’est
pas utilisé pendant une période prolongée.
Remarques relatives aux piles
Si du liquide de la cellule de pile entre en contact avec la
peau ou les yeux, rincez la zone touchée avec de l’eau et consultez un médecin.
Risque d‘ingestion! Les enfants en bas âge pour­raient avaler des piles et s’étouffer. Veuillez donc conser­ver les piles hors de portée des enfants en bas âge!
Respectez les signes de polarité plus (+) et moins (-).
Si la pile a coulé, enfilez des gants de protection et net-
toyez le compartiment à piles avec un chiffon sec.
Protégez les piles d’une chaleur excessive.
Risque d‘explosion! Ne jetez pas les piles dans le
feu.
Les piles ne doivent être ni rechargées, ni court-circui-
tées.
En cas de non utilisation prolongée de l’appareil, sortez
les piles du compartiment à piles.
Utilisez uniquement des piles identiques ou équivalentes.
Remplacez toujours l’ensemble des piles simultanément.
N’utilisez pas d’accumulateur!
Ne démontez, n’ouvrez ou ne cassez pas les piles.
Remarques relatives à la réparation et à la mise au
rebu
• Les piles ne sont pas des ordures ménagères. Veuillez jeter les piles usagées dans les conteneurs prévus à cet effet.
N’ouvrez pas l’appareil. Le non-respect de cette consigne
annulera la garantie.
Vous ne devez en aucun cas réparer ou ajuster l’appareil
vous-même. Le cas contraire, aucun fonctionnement irré­prochable n’est garanti.
Les réparations doivent être effectuées uniquement par le
service après-vente de ou des revendeurs agréés. Cepen-
29
dant avant de faire une réclamation, contrôlez d’abord les piles et changez-les, le cas échéant.
Para proteger el medio ambiente no se debe desechar el aparato al final de su vida útil junto con la basura doméstica. Se puede desechar en los puntos de recogida adecuados disponibles en su zona. Deseche el aparato según la Directiva euro­pea sobre residuos de aparatos eléctricos y electrónicos (RAEE). Para más información, póngase en contacto con la autoridad municipal competente en materia de elimina­ción de residuos.
3. Description de l´appareil / Affichages à
l´écran
1
2
1. Flexible du brassard
2. Brassard
3. Fiche du brassard
30
3
Loading...
+ 72 hidden pages