Installation, Service and User Instructions
(French version page 10)
Built-in gas hotplates BERTAZZONI
DIMENSIONS: 36 1/2’’ (925 mm)(W) x 211/4’’ (540 mm)(D)
|
Models B3H0..Q7X(2 or 5)D |
Type ‘A’ |
|
Models B3K0..U7X(2 or 5)D |
Type ‘B’ |
|
|
|
|
IMPORTANT: SAVE |
|
|
READ AND SAVE |
|
|
OBSERVE ALL |
|
|
|
|
|
WARNING: If |
exactly, a fire or |
|
explosion may |
death. |
|
Do not store or |
in the vicinity of |
|
this or any other |
|
|
WHAT TO DO IF |
|
-Do not try
-Do not touch any electrical switch.
-Do not use any phone in your building.
-Immediately call your gas supplier from a neighbor’s phone. Follow the gas supplier’s instructions.
-If you cannot reach your gas suppliers, call the fire department.
Installation and service must be performed by a qualified installer, service agency or the gas supplier.
Read this instruction booklet before installing and using the appliance.
The manufacturer will not be responsible for any damage to property or to persons caused by incorrect installation or improper use of the appliance.
The manufacturer reserves the right to make changes to its products when considered necessary and useful, without affecting the essential safety and operating characteristics.
This appliance has been designed for non-professional, domestic use only.
Cod. 310498
INDEX:
Installation Instructions……………………………………..………………………..pag.2 Inserting the hotplate……………………………………………..…………………..pag.3 Requirements……………………………………..……………………………….…..pag.3 Attaching the hotplate……………………………………..………………………….pag.4 Gas connection……………………………………..…………………………………pag.4 Electrical connection……………………………………..……………………….…..pag.5 Wiring diagrams……………………………………..…………………………….…..pag.5 Room ventilation…………………………………….…………………………………pag.5 Location and venting…………………………………….…………………………….pag.5 Replacement of nozzles……………………………………..………………………..pag.5 Regulation of burners……………………………………………...………………….pag.6 Descriptions…………………………………………………………………………….pag.6 Service & maintenance instructions……………………………..…………………..pag.6 Greasing the valves……………………………………………..…………………….pag.7 User instructions……………………………………………..………………………..pag.7 Using burners
Cleaning the appliance Figures
Installation
This appliance shall |
shall be installed in |
accordance with |
appliance must be |
installed in accordance |
|
The installation of |
. In the absence of |
local codes, Installations |
Fuel Gas Code |
ANSI Z223.1 – latest |
|
If local codes permit, |
or CGA certified |
design, max. 5 feet |
to the gas supply |
line. Do not bend or damage the flexible connector when moving the cooktop. The pressure regulator has ½” female pipe thread. You will need to determine the fitting required, depending on the size of your gas supply line, the flexible metal connector and the shutoff valve.
The appliance, when installed, must be electrically grounded in accordance with local codes or, in the absence of local codes, with the National Electrical Code, ANSI/NFPA 70.
The appliance and its individual shutoff valve must be disconnected from the gas supply piping system any pressure testing of that system at test pressure in excess of ½ psi (3,5 kPa).
The appliance must be isolated from the gas supply piping system by closing its individual manual shutoff valve during any pressure testing of the gas supply piping system at test pressures equal to or less than ½ psi (3.5 kPa).
For use with a pressure regulator. The regulator supplied must be used with this appliance. The gas appliance pressure regulator must be set for the gas with which the appliance is used.
This appliance can be used with Natural Gas and LP Gas. It is shipped from the factory adjusted for use with Natural Gas: CONVERSION FIXED ORIFICES ARE LOCATEDIN THE LITERATURE PACK SUPPLIED WITH THE UNIT.
Injectors kit for the change of type of gas are contained inside the package jointly with the hob installation kit and Instruction booklet.
The maximum inlet gas supply pressure incoming to the gas appliance pressure regulator is 20’’ water column (5 kPa) .
2
The minimum gas supply pressure for checking the regulator setting shall be at least 1“ w.c. (249 Pa) above the inlet specified manifold pressure to the appliance (this operating pressure is 4” w.c. (1.00 kPa) for Natural Gas and 11” w.c. (2.75 kPa) for LP Gas).
ATTENTION: A manual valve shall be installed in an accessible location in the gas line external to the appliance for the purpose of turning on or shutting off gas to the appliance
WARNING: Do not use aerosol sprays in the vicinity of this appliance while it is in operation
Inserting the hotplate
After having removed the various loose parts from the internal and external packing, make sure that the hotplate in not damaged and is suitable for the specific gas usage. The gas type label is on the underside of the hotplate base.
In case of doubt, do not use the appliance and contact skilled personnel.
Keep all the packing parts (polystyrene foam, cardboard, staples, etc.) away from children.
Consider the critical dimensions of the appliance, before making an opening in the top surface of the bench top. (relative measurements as per Fig 1- 2).
Requirements
1. Overhead clearances (Minimum values)
The minimum overhead clearances shall be in accordance with the minimum values indicated in the table n.1 and are shown and in the fig. 1- 2
Range hoods and exhaust fans shall be installed in accordance with the manufacturer’s instructions. However, in no case shall the clearance between the top of the highest burner of the cooking appliance and the range hood be less than 25 1/2”( 650mm).
Any other downward highest burner shall be protected for the
However, in no case Maximum depth for
2. Side clearances |
|
|
|
|
|
|
The different side |
|
|
|
in the table n.1 and |
||
are shawn and in the |
|
|
|
|
|
|
The cooking surface |
|
|
|
takes place and |
||
does not include those |
|
|
|
|
||
Table n.1 |
|
|
|
|
|
|
Hobs models |
|
|
|
models |
|
|
|
|
|
|
|
|
|
Min. Clearances |
|
inches (mm) |
|
Min. Clearances |
inches (mm) |
|
L1 |
|
20 1/2” (520) |
|
L10 |
35 10/16” (905) |
|
L2 |
|
1 9/16“ (40) |
|
L11 |
36“ (915) |
|
L3 |
|
2 5/32“ (55) |
|
W |
36 1/2“ (925) |
|
L4 |
|
18” (457) |
|
D |
21 1/4“ (540) |
|
L5 |
|
24” (610) |
|
B1 (*) |
1 9/16“ (40) |
|
L6 |
|
13” (330) |
|
B2 (*) |
6“ (152) |
|
L7 |
|
36 1/2“ (925) |
|
B3 (*) |
1 3/4” (45) |
|
L8 |
|
1 9/16“ (40)type A |
|
B4 (*) |
6“ (152) |
|
|
|
3/4“ (20) type B |
|
|
|
|
L9 |
|
6 3/8” (162) |
|
|
|
|
(*) Note:
-B1 is the min. clearance between the front edge of the appliance and the front edge of the cabinet.
-B2 and B4 are the min. clearance between the left/right side edge of the appliance and the side wall (if present).
-B3 is the min. clearance between the back edge of the appliance and the back wall.
3
Attaching the hotplate
To prevent liquids from leaking accidentally into the underlying storage space, the appliance is equipped with a special gasket. To apply this gasket, carefully follow the instructions in Fig. 3. Lay out the protective sealing strips along the edges of the opening in the bench top and carefully overlap the strip end. (See Fig. 3). insert the hotplate into the bench top opening. With a screwdriver assemble the brackets A to the hotplate bottom by means of the screws B. (See Fig. 4). Slide the hooks into position and secure them with the screws.
Trim the part of the sealing strips which extend beyond the hotplate base
Gas connection
Before connecting the appliance to the gas supply, first remove the plastic plug on which is pressfitted into the gas inlet union; to remove, just pull it off.
1.Check the ‘gas type’ sticker attached to the hotplate. Details of the injector sizes used are recorded on the data plate located on the base of the appliance.
2.This appliance shall be installed in accordance with installation requirements of the local gas authority of the appropriate installation code.
3.Before installing the hotplate consider the location of the gas supply and routing the gas line.(Refer fig.6)
4.For LPG models the gas supply is connected to the regulator which is supplied loose. The inlet connection has a 1/2” B.S.P. male thread. IT IS ESSENTIAL THAT
THE ELBOW ON THE APPLIANCE BE HELD FIRMLY WITH A SPANNER WHEN CONNECTING THE SUPPLY. DO NOT OVER TIGHTEN. The regulated pressure For LPG is 11” w.c. (See Fig. 5).
5. For NG models the |
The inlet connection |
has a 1/2” B.S.P. male |
|
THE ELBOW ON |
CONNECTING THE |
SUPPLY. DO NOT |
. 5). |
6. For gas inlet |
supply and making all |
connections check |
‘OFF’ position. Open |
the valve on the gas |
one at the time, by |
brushing the solution |
the fitting and re- |
check for leaks. If it |
use matches |
or flame for checking |
|
It is essential that the |
avoid gas leakage |
7.To checking inlet pressure at the appliance operate as follow:
a)Disconnect electric power before pressure checking be carried out.
b)Take off one of the gas burner cap and the relative flame spreader in order to get access to the burner injector.
c)Put in position the pressure detector directly on the burner injector afterward open the relative burner knob at maximum position keeping it pressed, then measure the outlet pressure from the burner injector.
d)Once the pressure checking has been carried out, replace the burner cap and flame spreader in the correct and original position and re-connect electric power to the appliance.
8.Turn on appliance control cock and light each burner. Check for a clear blue flame without yellow tipping. If burners show any abnormalities check that they are located properly and in line with the injector nipple.
9.Sometimes the burners will not ignite immediately and seem to ‘blow’ slightly when they do ignite. This usually due to air in the gas lines, which will clear itself within seconds.
10.If after following the instructions given, satisfactory performance cannot be obtained, contact the local gas authority for advice and assistance.
4
Electrical connection
The connection of the hobs to mains is effected via the flex and the three pin plug located underneath the hotplate. The appliance operate at a main voltage of 120V a.c., frequency 60Hz. Electric power absorption is about 1W for 5 gas burner version or 2W for 6 gas burners version.
WARNING: Electrical Grounding Instructions: This appliance is equipped with a (three-prong) grounding plug for your protection against shock hazard and should be plugged directly into a properly grounded receptable. Do not cut or remove the grounding prong from this plug.
Wiring diagrams |
Wiring diagram description |
|
For hotplate model A see Fig. 13. |
1. |
Cable terminal |
For hotplate model B see Fig. 14. |
2. |
Ignition switch |
|
3. |
Spark generator |
|
4. |
Ignition spark |
|
L. Black |
|
|
N. White |
|
|
T. Green (earth) |
Room ventilation – Location and venting.
ATTENTION: An exhaust fan may be used with the appliance; in each case it shall be installed in conformity with the national standards in force.
ATTENTION: Exhaust hood operation may affect other vented appliances; in each case it shall be installed in conformity with the national standards in force.
Conversion to
Before carrying out |
gas and electric |
supply. For Natural |
assembly described |
in fig. 5. |
|
- CHANGING THE |
|
To change the nozzles |
|
Lift up the burners |
mm and change the |
nozzles with those |
in TABLE A shown |
below. |
|
TABLE A: Adapting
Drop-in cooktop
Burner |
Position |
|
|
|
|
|
|
|
Rate |
By-pass size |
|
|
|
1/100mm |
Type |
[i.w.c.] |
[BTU/h] |
[W] |
[BTU/h] |
|
[W] |
[1/100mm] |
|
Auxiliary |
Front R |
92 |
NG |
4” |
3750 |
1098 |
900 |
|
264 |
Regulated |
|
|
|
56 |
LP(Propane) |
11” |
3750 |
1098 |
900 |
|
264 |
29 |
|
Semi-Rapid |
Rear L |
117 |
NG |
4” |
6000 |
1759 |
1500 |
|
439 |
Regulated |
|
|
Rear R |
73 |
LP(Propane) |
11” |
6300 |
1845 |
1500 |
|
439 |
36 |
|
Rapid |
Front L |
155 |
NG |
4” |
10400 |
2046 |
2500 |
|
732 |
Regulated |
|
|
|
98 |
LP(Propane) |
11” |
11400 |
3339 |
2500 |
|
732 |
47 |
|
|
Centre Inner |
80 |
NG |
4” |
|
|
|
|
|
|
Regulated |
Dual |
|
50 |
LP(Propane) |
11” |
NG |
17000 |
4980 |
900 |
|
264 |
29 |
burner |
Centre Outer |
N°2 x 130 |
NG |
4” |
LP |
18800 |
5507 |
|
Regulated |
||
|
|
|
|||||||||
|
|
N°2 x 83 |
LP(Propane) |
11” |
|
|
|
|
|
|
65 |
Drop-in cooktop with 6 workyop burners model B3K0..U7X(2 or 5)D
Burner |
Position |
Inj. size |
Gas |
Pressure |
|
Max Rate |
|
Min Rate |
By-pass size |
||
|
|
1/100mm |
Type |
[i.w.c.] |
[BTU/h] |
|
[W] |
[BTU/h] |
[W] |
[1/100mm] |
|
Auxiliary |
Front R |
0,92 |
NG |
4” |
3750 |
|
1098 |
900 |
264 |
Regulated |
|
|
|
0,56 |
LP(Propane) |
11” |
3750 |
|
1098 |
900 |
264 |
29 |
|
Semi-Rapid |
Rear L & C |
1,17 |
NG |
4” |
6000 |
|
1759 |
1500 |
429 |
Regulated |
|
|
Front C |
0,73 |
LP(Propane) |
11” |
6300 |
|
1845 |
1500 |
439 |
36 |
|
Rapid |
Front L |
1,55 |
NG |
4” |
10400 |
|
2046 |
2500 |
732 |
Regulated |
|
|
|
0,98 |
LP(Propane) |
11” |
11400 |
|
3339 |
2500 |
732 |
47 |
|
|
Centre Inner |
0,80 |
NG |
4” |
|
|
|
|
|
|
Regulated |
Dual |
|
0,50 |
LP(Propane) |
11” |
NG |
17000 |
|
4980 |
900 |
264 |
29 |
burner |
Centre Outer |
N°2 x 1,30 |
NG |
4” |
LP |
18800 |
|
5507 |
Regulated |
||
|
|
|
|||||||||
|
|
N°2 x 0,83 |
LP(Propane) |
11” |
|
|
|
|
|
|
65 |
5
CAUTION: save the orifices removed from the appliance for future use
Regulation of burners
Regulation of the "MINIMUM" on the burners
To regulate the minimum on the burners carry out the following procedure indicated below:
1)Turn on the burner and put the knob onto position MINIMUM ( small flame ).
2)Remove the knob ( Fig. 9) of the tap which is set for standard pressure. The knob is found on the bar of the tap itself.
3)Beside the tap bar on the work top, use a small screwdriver that fits the screw (gold) found on the lower part of the tap (auxiliary, semirapid, rapid Fig. 9) (dual fig.10) and turn the fixing screw to the right or left until the flame of the burner is regulated in the most suitable way to MINIMUM.
4)Make sure that that the flame does not go out when changing the position quickly from MAXIMUM to the MINIMUM position.
ATTENTION: The regulation described above can be carried out only with burners using natural gas, while with burners using propane gas the screw must be fully screwed in, in a clockwise direction.
Adaptation of the pressure regulator for use with different type of gas
The pressure regulator supplied with the appliance is a convertible type pressure regulator for use with Natural Gas at a nominal outlet pressure of 4” w.c. or LP gas at a nominal outlet pressure of 11” w.c. and it is pre-arranged from the factory to operate with one of these gas/pressure as indicated in the pre-arranging labels affixed on the appliance, package and Instruction booklet.
To convert the regulator for use with the other gas different from which one it is pre-arranged it is enough perform the following
1) |
Unscrew by hand |
|
2) |
Unscrew by hand |
stopper, afterward |
screw it again in |
“LP” and “NAT” with |
|
relative indicating |
|
|
3) |
Screw again by |
|
Operating in this way
Descriptions
DESCRIPTIVE CAPTION
1. |
Small Burner |
Model ‘B’ Fig. 12 |
2. |
Medium burner |
3.Rapid burner
4.Dual burner
5.Front left side burner control knob
6.Front right side burner control knob
7.Rear right side burner control knob
8.Rear left side burner control knob
9.Central burner control knob
10.Front central side burner control knob
11.Central rear side burner control knob
Service & maintenance instructions
Service and maintenance only to be carried out by an authorised person
To replace parts such as burners, valves and electric components, the hotplate must be removed from the bench top by releasing the attachment hooks, loosening the attachment screws of each burner, unscrewing the hotplate attachments nuts which are visible at the bottom of the surface, removing the hotplate top and finally replacing the defective parts.
Note: if the valves must be replaced, first disassemble the ignitions switches wires.
It is recommended to replace the valve gaskets each time the valve is replaced, thus ensuring a perfect seal between the body and the gas train.
WARNING: Disconnect power before servicing unit.
6
For the location of the wall receptable for the connection of the three-pin earthed plug of the appliance, see indications given in Fig. 1- 2
WARNING: After first installation of the appliance or after any service intervention concerning main gas parts of the appliance, make the leak test using water with soap on the gas connections in order to verify the correct installation. Do not use fire for gas leak testing.
Greasing the valves
If it becomes difficult to operate the valve, it should be greased immediately by following the instructions listed below
1.Disassemble the valve body by loosening the two screws located on the body of the valve. (See Fig. 15).
2.Extract and clean the seal cone and its housing with a rag soaked with thinners.
3.Lightly grease the cone with a special grease.
4.Insert the cone, moving it several times, remove it again, remove the excess grease and make sure that the gas passage ways are unobstructed.
5.Replace all the pieces in reverse order and check that the valve operates correctly.
User instructions
WARNINGS:
Keeping appliance area clear and free from combustible materials, gasoline and other flammable vapors and liquid.
Do not store dangerous |
store them in a |
safe place in order |
|
For safe use of |
|
Do not use aerosol |
|
For description of |
|
Using burners
A diagram is etched on the control panel above each knob which indicates which burner corresponds to that knob.
Manual ignition:
Manual ignition is always possible even when the power is cut off or in the event of prolonged power failure. Turn the knob that corresponds to the burner selected counterclockwise to the MAXIMUM position at the etched star (large flame) and place a lit match up to the burner.
Automatic electric ignition:
Turn the knob that corresponds to the burner selected counterclockwise to the MAXIMUM position at the etched star (large flame) and then press the knob down to activate the spark ignition. Release the knob some second after the burner has ignited.
Burners fitted with a safety device (thermocouple):
Turn the knob that corresponds to the burner selected counterclockwise to the MAXIMUM position at the etched star (large flame) and then press the knob down to activate the spark ignition. Once ignited, keep pressing the knob for about 10 seconds to allow the flame to heat the thermocouple. If the burner does not remain alight after releasing the knob repeat the above procedure,
Use of the Dual burner (Fig.16)
This model controls both the central and the external crown of the burner with just one valve.
To ignite the central crown and the external crown of the burner, press and turn the knob to the maximum delivery position 1
and hold it down until ignition; in this position both the internal and the external flame are at maximum.
Turn the knob to position 2 to have the external crown at minimum and the internal crown at maximum flame Turn the knob to position 3 to have the internal crown at maximum and the external crown off
Turn the knob to position 4 to have the internal crown at minimum and the external crown off.