Universal
FiberExpress® Brilliance
®
900 µm INSTALLATION INSTRUCTIONS
LC-SC-ST
2 4
Clean ber.
3
Strip off 24 ± 2 mm of buffer.Slide activator tab to the
open position (towards ferrule).
9
8
Create and maintain a bow
with the ber, while sliding
the activator tab to the closed position
(towards boot).
7
Insert ber into connector up to the 13
mm buffer mark.
6
Mark buffer at 13 mm.
5
Align the end of the ber’s buffer at 8
mm and cleave.
1
Slide boot onto ber.
10 11
To watch a video of
this installation, visit
youtube.com/beldenvid
900 µm Buffered Fiber (To Scale)
900 µm Buffered Fiber
8
+0.5
-0.0
13
50
40
30
20
10
0 mm
Do not turn on VFL light source until
ber is seated and activator tab is
closed. Light from VFL window has no
meaning until activator tab is closed.
Multimode
-
Light goes out.
Singlemode -
Light dims. *
* When using a Visual Fault
Locator (VFL) during termination
Install boot onto connector.
For complete details on this
procedure refer to Istallation
Guide PX105234.
*When using a Visual
fault Locator (VFL) during
termintation.
**When using a field cleaver
remove 40 mm of buffer.
A copy of the Guide is supplied
with each installation kit or visit
www.belden.com

8
Open the activator tab and insert ber
into the connector. Refer to point D for
ber
insertion depth.
4
Insert boot.
7
3
Strip jacket at point B*.
11
Spread the Kevlar around
the threads then gently screw
on boot and release bow.
6
Wrap ber cable around nger, then
strip off buffer to point C*.
2
Cut Kevlar® off at point A*.
10
Unclip the connector, then
create another bow and
maintain it until the next step.
1
Mark jacket at points A and B, then strip
jacket at point A*.
9
Create a bow and slide the
activator tab to the closed
position, then bring the boot
to the rear of the connector.
Quick Reference Diagram ( To Scale)
* See Quick Reference Diagram
below
®
Kevlar is a registered
trademark of DuPont
JACKETED INSTALLATION INSTRUCTIONS
Ensure ber is fully pushed
into jacket, then mark points
C, D and E*.
5
Unclip
Quick Reference Diagram (lengths to scale)
Precision
Cleaver
Jacket
Point B
Point A
Point EPoint DPoint C
Buffer
Fiber
5 mm
13 mm 30 mm
18 mm
Clean then cleave ber
at 8 mm.
+0.5
-0.0
Universal
FiberExpress® Brilliance
®
LC-SC-ST