Ethernet Module NX5000
Nexto Series
Doc. Code: CE114903 Revision: D
Altus S. A.
Product Description
Nexto Series is a powerful and complete Programmable Logic Controller (PLC) with unique and innovative features. Due to its
flexibility, smart design, enhanced diagnostics capabilities and modular architecture, Nexto PLC can be used for control
systems in medium and high-end applications or in high speed machinery
NX5000 redundancy link module, a part of Nexto Series, is used in applications that require more Ethernet Interfaces than
already available on Nexto CPUs or in applications where is necessary a high availability of automation system with uses of
network redundancy.
Its main features are:
Simultaneous support to MODBUS TCP and MODBUS RTU over TCP
Simultaneous operation as MODBUS master/client and server/slave
Redundant architecture support (half-cluster)
Network redundancy support (NIC teaming)
Hot swap support
Auto crossover Ethernet Interface
All configuration and parameterization through MasterTool IEC XE
One Touch Diag
Electronic Tag on Display
LCD and LED for diagnostic indication
Gratuitous ARP after CPU configuration and as active interface (redundancy)
Supports up to128 simultaneous connections
Protection against flood attacks
Ordering Information
Included Items
The product package contains the following items:
NX5000 module
Installation guide
Product Code
The following code should be used to purchase the product:

Ethernet Module NX5000
Nexto Series
Doc. Code: CE114903 Revision: D
Altus S. A.
Innovative Features
Nexto Series brings to the user several innovations in utilization, supervision and system maintenance. These features were
developed focusing a new experience in industrial automation. The list below shows some new features that users will find in the
NX5000 module:
One Touch Diag: One Touch Diag is an exclusive feature that Nexto Series brings to
PLCs. With this new concept, the user can check diagnostic information of any module
present in the system directly on CPU’s graphic display with one single press in the
diagnostic switch of the respective module. OTD is a powerful diagnostic tool that can be
used offline (without supervisor or programmer), reducing maintenance and commissioning
times.
ETD – Electronic Tag on Display: Another exclusive feature that Nexto Series brings to PLCs is the Electronic Tag on
Display. This new functionality brings the process of checking the tag names of any I/O pin or module used in the system
directly to the CPU’s graphic display. Along with this information, the user can check the description, as well. This feature is
extremely useful during maintenance and troubleshooting procedures.
DHW – Double Hardware Width: Nexto Series modules were designed to save space in user cabinets or machines. For this
reason, Nexto Series delivers two different module widths: Double Width (two backplane rack slots are required) and Single
Width (only one backplane rack slot is required). This concept allows the use of compact I/O modules with a high-density of I/O
points along with complex modules, like CPUs, fieldbus masters and power supply modules.
iF Product Design Award 2012: Nexto Series was the winner of iF Product Design Award 2012 in
industry + skilled trades group. This award is recognized internationally as a seal of quality and
excellence, considered the Oscars of the design in Europe.

Ethernet Module NX5000
Nexto Series
Doc. Code: CE114903 Revision: D
Altus S. A.
Product Features
General Features
Backplane rack occupation
Status and diagnostic indication
Display, web pages and CPU’s internal memory
Electronic Tag on Display (ETD)
Isolation
NET 1 to logic
NET 1 to protective earth
Logic to protective earth
1500 Vac / 1 minute
1500 Vac / 1 minute
1250 Vac / 1 minute
Current consumption from backplane
rack power supply
Operating and storage relative humidity
5 to 96 %, non-condensing
IEC 61131-2
CE – 2011/65/EU (RoHS), 2014/35/EU (LVD) and
2014/30/EU (EMC)
UL Listed - UL61010-1 (file E473496)
DNV-GL Type Approval – DNVGL-CG-0339 (TAA000013D)
EAC - CU TR 004/2011 (LVD) and CU TR 020/2011 (EMC)
Module dimensions (W x H x D)
36.00 x 114.63 x 115.30 mm
Package dimensions (W x H x D)
44.00 x 122.00 x 147.00 mm
Notes:
HSDN (High Speed Deterministic Network): HSDN is the name given to a network where the user can determine the
maximum latency for a given data transfer.
Logic: Logic is the name for the internal interfaces such as processors, memories and backplane rack interfaces.
Conformal coating: Conformal coating protects the electronic components inside the product from moisture, dust and other
harsh elements to electronic circuits.

Ethernet Module NX5000
Nexto Series
Doc. Code: CE114903 Revision: D
Altus S. A.
LLC (Logical Link Control)
TCP (Transmission Control Protocol)
MODBUS TCP client
MODBUS TCP server
MODBUS RTU over TCP master
MODBUS RTU over TCP slave
Tcp port configurable range
Maximum sockets supported value
LEDs – green (speed), yellow (link/activity)
Notes:
NET 1: Ethernet interface cannot be used for programming and debugging Nexto Series CPUs.
Gratuitous ARP: NET1 Ethernet interface sends spontaneously ARP type packets in broadcast, informing its IP and MAC
address for all devices interconnected to the network. These packets are sent during the download of a new application by the
MasterTool IEC XE software and in the startup of a NX5000 interface. 5 ARP commands are sent, with an initial interval of 200
ms, doubling the interval between every new triggered command, totalizing 3 s. Example: First trigger occurs at time 0, the
second one at 200 ms, the third one at 600 ms and so forth until the fifth trigger occurs at time 3 s.
Compatibility with Other Products
Nexto Series’ CPUs documentation must be consulted to check which CPUs allows the use of NX5000 modules. The table
below shows from which software version and product revision the listed modules are compatible with NX5000.
Software/firmware version
Note:
Product review: if the software/firmware is upgraded in the field, the product reviewing indicated on the label will no longer
match the actual review of the product.

Ethernet Module NX5000
Nexto Series
Doc. Code: CE114903 Revision: D
Altus S. A.
Physical Dimensions
Dimensions in mm.

Ethernet Module NX5000
Nexto Series
Doc. Code: CE114903 Revision: D
Altus S. A.
Installation
The following figure shows the electrical installation on the rack (backplane rack).
All information about electrical installation, mechanical assembly and module insertion can be found at Nexto Series User
Manual - MU214000.

Ethernet Module NX5000
Nexto Series
Doc. Code: CE114903 Revision: D
Altus S. A.
Configuration
Nexto Series CPUs User Manual - MU214605 must be consulted for information about module configuration.
Process Data
The process data, when available, are the variables used for access and module control. The table below shows all the variables
delivered by NX5000.
Reserved for internal use
Reserved for internal use
Reserved for internal use
Reserved for internal use
Reserved for internal use
Note:
Update: this field indicates if the respective process data is updated by CPU and NX5001. If it is set as Always, it means that
the process data is always updated.
Module Parameters
Initial address of Module Diagnostics on
%Q
Sets initial address of module Diagnostics.
Note:
Standard value: MasterTool IEC XE programmer fills it automatically, but allows the user to edit its initial offset. The limit
depends on the CPU supported model (details at CPUs Nexto Series User Manual – MU214605).
Maintenance
Altus recommends that all modules’ connections be checked and that all dust or any kind of dirt at the module’s enclosure be
removed at least every 6 months.
NX5000 offers five important features to assist the user during maintenance: Electronic Tag on Display, One Touch Diag,
Status and diagnostics indicators, web page with complete status and diagnostics list and status and diagnostics mapped to
internal memory.
Electronic Tag on Display and One Touch Diag
Electronic Tag on Display and One Touch Diag are important features that provides for the user the option to check the tag,
description and diagnostics related to a given module directly on the CPU display.
To check the tag and diagnostics of a given module, it’s required only one short press on its diagnostic switch. After pressing
once, CPU will start to scroll tag information and diagnostic information of the module. To access the respective description for
the module, just long press the diagnostic switch of the respective module.
More information about Electronic Tag on Display can be found at Nexto CPU User Manual – MU214605.
Status/Diagnostic Indications
All Nexto slave modules have a display with the following symbols: D, E, 0, 1 and numeral characters. The states of the
symbols D, E, 0, 1 are common for all Nexto series slave modules, these states can be consulted in the table below.
The meaning of the numeral characters can be different for specific modules.

Ethernet Module NX5000
Nexto Series
Doc. Code: CE114903 Revision: D
Altus S. A.
Display fail or module
off
Disconnected module.
No Power supply.
Hardware failure
Check if the module is
completely connected to
the backplane rack and
if the backplane rack is
supplied by an external
power supply.
There is at least one
active diagnostic related
to the module NX5000
Check what the active
diagnostic is. More
information can be
found at Maintenance
section of this
document
Check if CPU is in RUN
mode. More information
can be found on CPU’s
documentation
Failure in some
hardware or software
component, which does
not have impact on the
basic functionality of the
product
Check the module
diagnostic information.
If it is a hardware fault,
provide the replacement
of this part. If it is a
software fault, please
contact the Technical
Support
Check if the module
parameters are correct
Loss of communication
between module and
CPU
Check if the module is
completely connected to
the backplane rack.
Check if CPU is in RUN
mode.
Contact Altus’ support
team in case of fatal
hardware error.
Note:
Fatal hardware fault: Please contact Altus’ support team in case of fatal hardware fault.
0, 1 and Numeral Characters
The segments 0 and 1 should be normally off. These two segments will start to blink when the module is on the Diagnostic
Mode (Electronic Tag on Display and One Touch Diag).
RJ45 Connector LEDs
Both LEDs placed in the RJ45 connector; identified by NET 1, help the user in the installed physical network problem detection,
indicating the network LINK speed and the existence of interface communication traffic. The LEDs description is presented in
the table below.
Occurrence of Ethernet network transmission or reception, for or to this IP address. It
blinks when there’s module demand, not on every transmission or reception, i.e. blinking
frequency doesn’t correspond to data transmission or reception frequency.

Ethernet Module NX5000
Nexto Series
Doc. Code: CE114903 Revision: D
Altus S. A.
Web Page with Complete Status and Diagnostic List
Another way to access diagnostic information on Nexto Series is via web pages. Nexto Series CPUs have an embedded web
pages server that provides all Nexto status and diagnostic information, which can be accessed using a simple browser.
More information about web page with complete status and diagnostic list can be found at Nexto Series CPUs’ User Manual –
MU214605.
Status and Diagnostics Mapped to Variables
All NX4010’s diagnostics can be accessed through variables that can be handled by the user application or even forwarded to a
supervisory system using a communication channel. There are two different ways to access diagnostics in the user application:
using symbolic variables with AT directive or addressing memory. Altus recommends use symbolic variables for diagnostic
accessing. The table below shows all available diagnostics for NX4010 and their respective memory address, description,
symbolic variable and string that will be shown on the CPU graphical display and web.
Direct Representation
Variable
Symbolic Variable
DG_NX5000
tGeneral.bActiveDiagnostics
TRUE – Module has active
diagnostics
FALSE – Module doesn’t
have active diagnostic
tGeneral. bConfigMismatch
TRUE – Watchdog has been
detected
tGeneral. bOTDSwitchError
TRUE – Failure on the
diagnostic switch
FALSE – No failure on the
diagnostic switch
TRUE – NET 1 interface not
properly connected
FALSE – Interface NET 1
connected
TRUE – Internal failure on
NET 1 interface
FALSE – No internal failure
on NET 1 interface
0..7 - tNX5000.bStsEthSpd
0- NET 1 Link down
1- NET1 10 Mbps
2- NET1 100 Mbps
Notes:
Direct Representation Variable: “n” is the address defined in the field %Q Start Address of Diagnostic Area on the NX5000’s
configuration screen – Modules Parameters tab in the MasterTool IEC XE.
Symbolic Variable: Some symbolic variables serve to accessing diagnostics. This diagnostics are stored into the addressing
memory, then the AT directive is used to map the symbolic variables in the addressing memory. The directive AT is a reserved
word in the MasterTool IEC XE that uses this directive to declares the diagnostics automatically on a symbolic variables. All
symbolic variables declared automatically can be found inside of Diagnostics object.

Ethernet Module NX5000
Nexto Series
Doc. Code: CE114903 Revision: D
Altus S. A.
Detailed Diagnostics
The list below indicates additional information related to NX5000’s status and diagnostics that can be found on variables.
Direct Representation
Variable
AT Variable
DG_modulename.
tStsEthernet
Transmission collision errors
Manuals
For correct application, MODBUS configuration and utilization Nexto Series CPUs User Manual - MU214605 must be
consulted.
For further technical details, configuration, installation and programming of Nexto Series, the table below should be consulted.
The table below is only a guide of some relevant documents that can be useful during the use, maintenance, and programming
of NX5000. The complete and updated table containing all documents of Nexto Series can be found at Nexto Series User
Manual – MU214600.
CE114000
CT114000
CS114000
Nexto Series – Features and Configuration
Série Nexto – Características e Configurações
Serie Nexto – Especificaciones y Configuraciones
English
Portuguese
Spanish
MU214600
MU214000
MU214300
Nexto Series User Manual
Manual de Usuário Série Nexto
Manual Del Usuario Nexto
English
Portuguese
Spanish
MU214605
MU214100
MU214305
Nexto Series CPUs User Manual
Manual de Usuário UCPs Série Nexto
Manual del Usuario UCPs Serie Nexto
English
Portuguese
Spanish
MU299609
MU299048
MU299800
MasterTool IEC XE User Manual
Manual de Usuário MasterTool IEC XE
Manual del Usuario MasterTool IEC XE
English
Portuguese
Spanish