Dimensions (W x H x D) 100 mm x 106 mm x 92 mm
Weight approx. 575 g
Operating/storage temperature -25…+60 °C/-40…+85 °C
Relative humidity 95 %, no condensation
Vibration/shock resistance conforms to EN 60068-2-6/EN 60068-2-27
EMC immunity/emission conforms to EN 61000-6-2/EN 61000-6-4
Protection class IP 20
Approvals/markings CE, UL, ATEX
Ex marking II 3 G Ex nA IIC T4 Gc
TC3 performance class Performance (40); please see here for an overview of all the TwinCAT 3 performance classes
Ordering information E-
busK-bus
no
operating
system
Windows
Embedded
CE 6
Windows
Embedded
Standard 2009
no
TwinCAT
TwinCAT 2
PLC
runtime
TwinCAT 2
NC PTP
runtime
TwinCAT 3
runtime
(XAR)
CX5020-0100 x – x – – x – – –
CX5020-0110 x – – x – x – – –
CX5020-0111 x – – x – – x – –
CX5020-0112 x – – x – – x x –
CX5020-0115 x – – x – – – – x
CX5020-0120 x – – – x* x – – –
CX5020-0121 x – – – x* – x – –
CX5020-0122 x – – – x* – x x –
CX5020-0125 x – – – x* – – – x
CX5020-1100 – x x – – x – – –
CX5020-1110 – x – x – x – – –
CX5020-1111 – x – x – – x – –
CX5020-1112 – x – x – – x x –
CX5020-1115 – x – x – – – – x
CX5020-1120 – x – – x* x – – –
CX5020-1121 – x – – x* – x – –
CX5020-1122 – x – – x* – x x –
CX5020-1125 – x – – x* – – – x
Accessories
CX1900-0204 1 GB DDR2 RAM for CX5020, instead of 512 MB DDR2 RAM; pre-assembled ex factory
CX1800-0401 Windows Embedded Standard 7 P 32 bit instead of Windows Embedded Standard 2009; requires at least 1 GB RAM and 8
GB Compact Flash; supported devices: CX5020
CX1900-00xx Optionally expandable memory ex factory.
Instead of 128 MB Compact Flash card: 1, 2, 4 and 8 GB Compact Flash card
CX1900-00xx Aditionally expandable memory: 1, 2, 4 and 8 GB Compact Flash card
CX1900-001x Formatting a Compact Flash card (bootable)
CX1900-0105 Device modification for CX5010 and CX5020 Embedded PCs according to the requirements for ATEX certification. The
modification is mandatory for the usage of the devices in hazardous areas, Zone 2. It includes the modification and
repositioning of the device label as well as a mounting bracket installed ex works for mechanical locking of the connectors.
Product labeling:
ATEX: II 3 G Ex nA IIC T4 Gc
Read the device documentation for use in hazardous areas carefully.
Optional interfaces
CX5020-N020 audio interface, 3 x 3.5 mm jack sockets, Line In, Mic In, Line Out or 5.1 Surround
CX5020-N030 RS232 interface, D-sub plug, 9-pin
CX5020-N031 RS485 interface, D-sub socket, 9-pin, configuration as an end point, without echo, termination on
CX5020-N031-0001 RS485 interface, D-sub socket, 9-pin, configuration as an end point, with echo, termination on
CX5020-N031-0002 RS485 interface, D-sub socket, 9-pin, configuration as drop point, without echo, termination off
CX5020-N031-0003 RS485 interface, D-sub socket, 9-pin, configuration as drop point, with echo, termination off
CX5020-N031-0004 RS422 interface, D-sub socket, 9-pin, configuration as full duplex end point, termination on
CX5020-B110 EtherCAT slave interface, EtherCAT IN and OUT (2 x RJ45)
CX5020-M310 PROFIBUS master interface, D-sub socket, 9-pin
CX5020-B310 PROFIBUS slave interface, D-sub socket, 9-pin
CX5020-M510 CANopen master interface, D-sub plug, 9-pin
CX5020-B510 CANopen slave interface, D-sub plug, 9-pin
CX5020-M930 PROFINET RT, controller interface, Ethernet (2 x RJ45)
CX5020-B930 PROFINET RT, device interface, Ethernet (2 x RJ45 switched)