This description is only intended for the use of trained specialists in control and automation engineering
who are familiar with the applicable national standards. It is essential that the following notes and
explanations are followed when installing and commissioning these components.
The responsible staff must ensure that the application or use of the products described satisfy all the
requirements for safety, including all the relevant laws, regulations, guidelines and standards.
1.1.1 Liability Conditions
The documentation has been prepared with care. The products described are, however, constantly under
development. For that reason the documentation is not in every case checked for consistency with
performance data, standards or other characteristics. In the event that it contains technical or editorial
errors, we retain the right to make alterations at any time and without warning. No claims for the
modification of products that have already been supplied may be made on the basis of the data, diagrams
and descriptions in this documentation.
1.1.2 Trademarks
Beckhoff®, TwinCAT®, EtherCAT®, Safety over EtherCAT®, TwinSAFE® and XFC® are registered
trademarks of and licensed by Beckhoff Automation GmbH.
Other designations used in this publication may be trademarks whose use by third parties for their own
purposes could violate the rights of the owners.
1.1.3 Patent Pending
The EtherCAT Technology is covered, including but not limited to the following patent applications and
patents: EP1590927, EP1789857, DE102004044764, DE102007017835 with corresponding applications
or registrations in various other countries.
The TwinCAT Technology is covered, including but not limited to the following patent applications and
patents: EP0851348, US6167425 with corresponding applications or registrations in various other
countries.
Beckhoff Automation GmbH.
The reproduction, distribution and utilization of this document as well as the communication of its contents
to others without express authorization are prohibited. Offenders will be held liable for the payment of
damages. All rights reserved in the event of the grant of a patent, utility model or design.
1.1.5 State at Delivery
All the components are supplied in particular hardware and software configurations appropriate for the
application. Modifications to hardware or software configurations other than those described in the
documentation are not permitted, and nullify the liability of Beckhoff Automation GmbH.
1.1.6 Delivery conditions
In addition, the general delivery conditions of the company Beckhoff Automation GmbH apply.
CU8006-0000 3
Foreword
1.2 Description of safety symbols
The following safety symbols are used in this operating manual. They are intended to alert the reader to
the associated safety instructions.
Acute risk of injury!
If you do not adhere the safety advise adjoining this symbol, there is immediate
DANGER
WARNING
CAUTION
danger to life and health of individuals!
Risk of injury!
If you do not adhere the safety advise adjoining this symbol, there is danger to life and
health of individuals!
Hazard to individuals!
If you do not adhere the safety advise adjoining this symbol, there is obvious hazard to
individuals!
Hazard to devices and environment
If you do not adhere the notice adjoining this symbol, there is obvious hazard to
Attention
Note
materials and environment.
Note or pointer
This symbol indicates information that contributes to better understanding.
1.3 Operator’s obligation to exercise diligence
The operator must ensure that
• the product is only used as intended (see chapter Product Description)
• the product is in a sound condition and in working order during operation (see chapter
Maintenance)
• the product is operated, maintained and repaired only by suitably qualified and authorized
personnel
• the personnel is instructed regularly about relevant occupational safety and environmental
protection aspects, and is familiar with the operating manual and in particular the safety notes
contained herein
• the operation manual is in good condition and complete, and always available for reference at the
location of the product
• none of the safety and warning notes attached to product are removed, and that all notes remain
legible.
4CU8006-0000
Product Description
2 Product Description
2.1 Product Overview
The CU8006 DIN rail-mount USB hub has four ports and supports the USB 3.0 data transfer rate of up to
5 Gbit/s, but is also compatible with slower USB standards. USB 3.0 devices can be connected at a
distance of up to 3 m. Connection to USB 1.1/ USB 2.0 devices is possible with 5-m cables.
An 1 m USB cable is provided for connecting the USB hub with the PC. 3 m USB 3.0 cables are permitted
between PC and CU8006.
The USB hub can be used universally in automation and office applications. The USB hub meets the
special requirements of industrial applications through several outstanding features:
• user-friendly installation via integrated top-hat rail adapter
• 24 V
• delivers up to 1 A supply current from each USB downstream port
• USB 3.0 input, compatible to all USB standards
• compact industrial design
• clear quick diagnostic by separate LEDs for each USB port.
supply voltage – the standard in industrial environments
DC
CU8006-0000 5
Product Description
2.2 Connections
2.2.1 Power Supply
The USB hub CU8006-0000 requires a 24 V
supply for it’s operation. The connection is made by
DC
means of the terminal X10, labeled 24 V DC. This supply feeds the hub electronics and, over the USB
downstream ports, the connected USB devices (5 V
). It is protected against polarity reversal.
DC
2.2.1.1 UL Requirements
UL Requirements
Attention
To meet the UL requirements, the device must not be connected to unlimited power
sources!
2.2.1.2 Pin Assignment Power Supply Connector
Pin Assignment
1 GND
2 0 V
3 +24 V DC
6CU8006-0000
Product Description
2.2.2 Data Connections
There are two kind of data connectors:
• USB Port Type B (USB IN)
• USB Port Type A (downstream port).
The pins are described below:
2.2.2.1 USB Type B Port (X20) (standard cable)
USB IN
2.2.2.2 USB Type A Port (X31, X32, X33, X34) (standard cable)
Downstream Port
2.2.2.3 Pin assignment
Pin Assignment
1 VCC
2 Data -
3 Data +
4 GND
5 SSRX -
6 SSRX +
7 GND_DRAIN
8 SSTX -
9 SSTX +
Shield Shield
CU8006-0000 7
Product Description
2.3 LED-Diagnostic
LED Allocation State Meaning
off no supply voltage P10 Power supply
shining green supply voltage is provided
shining green the total current of all 4 downstream ports is less than 4 A P11 Current
control
shining red the total current of all 4 downstream ports is bigger than 4 A
shining green supply voltage 5 V is provided P31 USB Port 1
shining red no supply voltage, port not operational
shining green supply voltage 5 V is provided P32 USB Port 2
shining red no supply voltage, port not operational
shining green supply voltage 5 V is provided P33 USB Port 3
shining red no supply voltage, port not operational
shining green supply voltage 5 V is provided P34 USB Port 4
shining red no supply voltage, port not operational
8CU8006-0000
Installation
3 Installation
3.1 Transport and Unpacking
The specified storage conditions must be observed (see chapter Technical Data).
3.1.1 Transport
Despite the robust design of the unit, the components are sensitive to strong vibrations and impacts.
During transport, the unit should therefore be protected from excessive mechanical stress. Therefore,
please use the original packaging.
Danger of damage to the unit
If the device is transported in cold weather or is exposed to extreme variations in
Attention
Prior to operation, the unit must be allowed to slowly adjust to room temperature. Should condensation
occur, a delay time of approximately 12 hours must be allowed before the unit is switched on.
temperature, make sure that moisture (condensation) does not form on or inside the
device.
3.1.2 Unpacking
Proceed as follows to unpack the unit:
1. Remove packaging
2. Do not discard the original packaging. Keep it for future relocation
3. Check the delivery for completeness by comparing it with your order
4. Please keep the associated paperwork. It contains important information for handling the unit
5. Check the contents for visible shipping damage.
If you notice any shipping damage or inconsistencies between the contents and your order, you should
notify Beckhoff Service.
CU8006-0000 9
Installation
3.2 Mounting/ Demounting
The USB hub CU8006-0000 can be snapped onto a 35 mm mounting rail conforms to EN 50022:
To release the CU8006-0000 from the mounting rail:
1. first pull the lug at the bottom of the hub downwards by using a screw driver (1)
2. then pull the hub from the mounting rail (2).
10CU8006-0000
Installation
3.3 Connecting devices
The power supply plug must be withdrawn
Please read the documentation for the external devices prior to connecting them!
Attention
3.3.1 Mounting power supply connector
The connector for the power supply has a clamp. It will be installed with a screwdriver:
During thunderstorms, plug connector must neither be inserted nor removed!
When disconnecting a plug connector, always handle it at the plug. Do not pull the
cable!
2. 1. 3.4.
1. Insert screwdriver into the left hole.
2. Plug bared cable into right hole.
3. Remove screwdriver.
4. The Cable is installed.
3.3.2 Connecting cables
The connections are documented in the section Product Description.
There are the following options when connecting the CU8006-0000:
• Connect the CU8006-0000 USB hub with the power supply and connect the USB type B port
before connecting the downstream ports.
• Only connect the USB type B port and the downstream ports. When operated without power
supply the total current of all 4 downstream ports must not exceed the maximum current at the
Industrial PC.
• Only connect the power supply of the CU8006-0000 USB hub and the downstream ports. Now
the CU8006-0000 can be used as USB power supply, e.g. for charging USB devices.
It is useful to connect the power supply first (via USB type B port and/ or 24 V DC), then connect the
downstream ports.
CU8006-0000 11
Operation
4 Operation
4.1 Operating modes
The CU8006-0000 USB hub can be operated with or without power supply according to the intended
purpose. When operated without power supply the total current of all 4 downstream ports must not
exceed the maximum current at the Industrial PC.
If the USB type B port is not connected, the CU8006-0000 can be used as USB power supply, e.g. for
charging USB devices.
4.2 Maintenance
Please also refer to chapter Operator’s obligation to exercise diligence.
4.2.1 Cleaning
Disconnect power supply
DANGER
The device can be cleaned with a soft, damp cloth. Do not use any aggressive cleaning materials,
thinners, scouring material or hard objects that could cause scratches.
Switch off the device and all connected devices, and disconnect the device from the
power supply.
4.2.2 Maintenance
The CU8006-0000 USB hub is maintenance-free.
4.3 Shutting down
4.3.1 Disposal
Observe national electronics scrap regulations
Note
In order to dispose of the device, it must be removed and fully dismantled:
Observe the national electronics scrap regulations when disposing of the device.
• Housing components (polycarbonate, polyamide (PA6.6)) are suitable for plastic recycling
• Metal parts can be sent for metal recycling
• Electronic parts such as disk drives and circuit boards must be disposed of in accordance with
national electronics scrap regulations.
12CU8006-0000
Dimensions
5 Dimensions
The product is characterized by small overall installed size. With a height of 100 mm, the module
dimensions exactly match those of the Beckhoff Bus Terminals. Together with the lowered connector
surfaces, this means that it can be used in a standard terminal box with a height of 120 mm
.
CU8006-0000 13
Technical Data
6 Technical Data
Product name CU8006-0000
Number of USB type B ports (upstream) 1
Number of USB type A ports (downstream) 4
Supported standards USB 1.1, USB 2.0, USB 3.0
Supported baud rates USB 12 Mbit/s, 480 Mbit/s, 5 Gbit/s
Output current per port up to 1.0 A (at 5 V)
Status display via LEDs
USB wiring length USB1.1/ USB2.0: maximum 5 meters
USB3.0: maximum 3 meters
Power supply
Current consumption from 24 V open circuit operation: 80 mA
Dimensions (W x H x D) app. 34 mm x 100 mm x 86 mm
Weight approx. 120 g
Permissible ambient temperature -0°C to +55°C (operation)
Permissible relative humidity 5% to 95%, no condensation
EMC resistance burst / ESD EN 60000-6-2 / EN 60000-6-4
Vibration / Shock resistance according to EN 60068-2-6 / EN 60068-2-27
Assembly on 35 mm mounting rail conforms to EN 50022
Installation position any
Protection class IP20
Approvals CE, UL
24 V
To meet the UL requirements use 4 A fuse or class 2 power
supply!
if connected with host: 110 mA
maximum: 1 A (with USB devices connected)
(with power supply terminal and lug for mounting rail
release)
-25°C to +70°C (transport/ storage)
(-25% / +50%), protected against polarity reversal.
DC
14CU8006-0000
Appendix
7 Appendix
7.1 Beckhoff Support and Service
Beckhoff and their partners around the world offer comprehensive support and service, making available
fast and competent assistance with all questions related to Beckhoff products and system solutions.
7.1.1 Beckhoff branches and partner companies
Please contact your Beckhoff branch office or partner company for local support and service on Beckhoff
products!
The contact addresses for your country can be found in the list of Beckhoff branches and partner
companies: www.beckhoff.com
Support offers you comprehensive technical assistance, helping you not only with the application of
individual Beckhoff products, but also with other, wide-ranging services:
• world-wide support
• design, programming and commissioning of complex automation systems
• and extensive training program for Beckhoff system components
If servicing is required, please quote the project number of your product.
CU8006-0000 15
Appendix
7.2 Approvals for USA and Canada
7.3 FCC Approval for USA
FCC: Federal Communications Commission Radio Frequency Interference Statement
This equipment has been tested and found to comply with the limits for a Class A digital device, pursuant
to Part 15 of the FCC Rules. These limits are designed to provide reasonable protection against harmful
interference when the equipment is operated in a commercial environment. This equipment generates,
uses, and can radiate radio frequency energy and, if not installed and used in accordance with the
instruction manual, may cause harmful interference to radio communications. Operation of this equipment
in a residential area is likely to cause harmful interference in which case the user will be required to
correct the interference at his own expense.
Technical modifications
Technical modifications to the device may cause the loss of the FCC approval.
Note
7.4 FCC Approval for Canada
FCC: Canadian Notice
This equipment does not exceed the Class A limits for radiated emissions as described in the Radio
Interference Regulations of the Canadian Department of Communications.
16CU8006-0000
Loading...
+ hidden pages
You need points to download manuals.
1 point = 1 manual.
You can buy points or you can get point for every manual you upload.