Microwave Hood Combination
PRODUCT MODEL NUMBERS |
PRODUCT DIMENSIONS |
||
GMH3204XV |
WMH1162XV |
WMH2175XV |
|
GMH5205XV |
WMH1163XV |
WMH2205XV |
|
GMH6185XV |
WMH1164XW |
WMH3205XV |
|
|
|
17 |
" |
|
|
(43.8 cm) |
Electrical: A 120-Volt, 60-Hz, AC-only, 15or 20-amp fused electrical supply with a fuse or circuit breaker. A time-delay fuse or time-delay circuit breaker is recommended. It is recommended that a separate circuit serving only this microwave oven be provided.
16 |
" |
|
|
(41.3 |
cm) |
||
|
|
|
|
|
|
|
|
VENTING REQUIREMENTS
A 3¹⁄" x 10" (8.3 x 25.4 cm) rectangular or 6" (15.2 cm) round vent should be used.
15 |
" |
(40. |
|
0 |
cm) |
|
|
) |
|
.0 cm |
29 |
" (76 |
The total length of the vent system including straight vent, elbow(s), transitions and wall |
CABINET OPENING DIMENSIONS |
|
|||
or roof caps must not exceed the equivalent of 140 ft (42.7 m) for either type of vent. |
The grounded 3-prong outlet must be inside the upper cabinet. |
||||
For best performance, use no more than three 90° elbows. |
|||||
To calculate the length of the system you need, add the equivalent length for each vent |
A |
B |
|||
piece used in the system. See the following examples: |
|
|
|||
A |
B |
|
C |
|
|
|
|
|
|
|
12" (30.5 cm) min. |
|
|
|
|
|
14" (35.6 cm) max. |
|
|
|
|
30" |
upper cabinet and |
|
|
|
|
(76.2 cm) |
side cabinet depth |
|
|
|
|
min. |
|
|
|
|
|
30" |
|
|
|
|
|
(76.2 cm) |
|
|
|
|
|
typical* |
|
D |
E |
F |
G |
66" (167.6 cm) min. |
|
|
|
|
|
|
|
A. Rectangular to round transition piece: 3 |
" x 10" to 6" = 5 ft |
|
|
||
(8.3 x 25.4 cm to 15.2 cm = 1.5 m) |
|
|
|
|
|
B. Roof cap: 3 " x 10" = 24 ft (8.3 x 25.4 cm = 7.3 m) |
|
|
|||
C. 90° elbow: 3 " x 10" = 25 ft (8.3 x 25.4 cm = 7.6 m) |
|
|
|||
D. 90° elbow: 6" = 10 ft (15.2 cm = 3 m) |
|
|
|
||
E. Wall cap: 3 " x 10" = 40 ft (8.3 x 25.4 cm = 12.2 m) |
|
|
|||
F. 45° elbow: 6" = 5 ft (15.2 cm = 1.5 m) |
|
|
|
||
G. 90° flat elbow: 3 |
" x 10" = 10 ft (8.3 x 25.4 cm = 3 m) |
|
|
6" (15.2 cm) vent system = 73 ft (22.2 m) total |
|
|
|
|
|
|
|
|
|||||||||||||||||||||
A |
|
|
|
|
|
|
|
|
|
B |
|
|
|
|
|
|
|
|
|||||||||||
|
|
|
|
|
|
|
|
|
|
|
|
6 ft (1.8 m) |
|
|
|
|
|
|
|
|
|
A. 2" x 4" wall stud |
|||||||
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|||||||||||
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
||
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
||
|
2 ft |
|
|
|
|
|
|
|
|
A. Two 90° elbows = 20 ft (6.1 m) |
|
|
|
|
|
|
|||||||||||||
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|||||||||||||||
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|||||||||||||
|
(0.6 m) |
|
|
|
|
|
|
|
|
B. 1 wall cap = 40 ft (12.2 m) |
|
|
|
|
|
|
B. Grounded 3-prong outlet |
||||||||||||
|
|
|
|
|
|
|
|
|
|
|
|
C. 1 rectangular to round transition |
|
|
|
|
*30" (76.2 cm) is typical for 66" (167.6 cm) installation height. |
||||||||||||
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
||||||||||||||
|
|
|
|
|
|
|
|
|
|
|
|
|
piece = 5 ft (1.5 m) |
|
|
|
|
|
Exact dimensions may vary depending on type of range/cooktop below. |
||||||||||
|
|
|
|
|
|
|
|
|
|
|
|
D. 2 ft (0.6 m) + 6 ft (1.8 m) |
|
|
|
|
|
||||||||||||
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
||||||||||
|
|
|
|
|
|
|
|
|
|
|
|
|
straight = 8 ft (2.4 m) |
Rectangular to Round Transition for Roof Venting |
|||||||||||||||
|
C |
D |
|||||||||||||||||||||||||||
|
NOTE: The minimum 3" (7.6 cm) clearance must exist between |
||||||||||||||||||||||||||||
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
||||||||
3 " x 10" (8.3 x 25.4 cm) vent system = 73 ft (22.2 m) total |
the top of the microwave oven and the rectangular to round |
||||||||||||||||||||||||||||
transition piece so that the damper can open freely and fully. |
|||||||||||||||||||||||||||||
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|||
|
|
|
|
|
|
|
A |
|
|
|
|
|
B |
|
|
|
|
|
|
|
|
|
|||||||
|
|
|
|
|
|
|
|
|
|
|
|
6 ft (1.8 m) |
|
|
A |
|
|
|
|
||||||||||
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
||||
|
2 ft |
|
|
|
|
|
|
|
|
|
|
|
|
|
B |
|
|
|
|
||||||||||
|
(0.6 m) |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
D |
|
|||||||
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
C |
|
|
A. Roof cap |
||||
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
||||||||
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|||||
|
|
|
|
|
|
|
|
|
|
|
|
C |
|
|
|
|
|
|
|
|
B. 6" (15.2 cm) min. diameter round vent |
||||||||
A. One 3 " x 10" (8.3 x 25.4 cm) 90° elbow = 25 ft (7.6 m) |
|
|
|
|
|
|
E |
C. Elbow (for wall venting only) |
|||||||||||||||||||||
|
|
|
|
|
|
||||||||||||||||||||||||
B. 1 wall cap = 40 ft (12.2 m) |
|
|
|
|
|
|
D. Wall cap |
||||||||||||||||||||||
|
|
|
|
||||||||||||||||||||||||||
|
|
|
|
|
|
|
|||||||||||||||||||||||
|
|
|
|
|
|
|
E. 3 " x 10" to 6" (8.3 x 25.4 cm to 15.2 cm) |
||||||||||||||||||||||
C. 2 ft (0.6 m) + 6 ft (1.8 m) straight = 8 ft (2.4 m) |
3" (7.6 cm) |
|
|
F |
|||||||||||||||||||||||||
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
rectangular to round transition piece |
F. Vent extension piece, at least 3" (7.6 cm) high
Because Whirlpool Corporation policy includes a continuous commitment to improve our products, we reserve the right to change materials and specifications without notice.
Dimensions are for planning purposes only. For complete details, see Installation |
Ref. W10247296B |
Instructions packed with product. Specifications subject to change without notice. |
9/30/10 |