THIS APPLIANCE IS INTENDED FOR OTHER THAN HOUSE HOLD USE
All BAKEMAX commerical gas appliances are manufactured by skilled craftsman using the finest quality materials.
PROPER installation by qualified personnel is essential for safe, efficient, and trouble-free operation of the unit. Any alteration and/or
tampering, without proper knowledge, tools, and test equipment, is DANGEROUS and will void all warranties. The installation must
conform with local codes, or in the absence of locel codes, with the National Fuel Gas Code, ANSIZ223.1- latest edition.
PRESSURE TESTING: FAILURE TO INSTALL PRESSURE REGULATOR WILL VOID WARRANTY.
(Most units have a convertible regulator.) The appliance and its indivdual shut-off valve must be disconnected from the gas supply
piping system during any pressure testing of that system at test pressure in excess of 1/2 psig (3.45 kPa). The appliance must be isolated
from the gas supply piping system by closing its individual manual shut-off valve during any pressure testing of the gas supply piping
system at test pressures equal to or less than 1/2 psig (3.45 kPa).
NOTICE
The proper installation of this gas appliance is the total responsibility of the end user. It is the responsibility of the purchaser to
determine that the installer is qualified in installation procedures. Conversion, connecting gas lines, calibrating thermostats, burners,
lighters, setting gas pressure with manometer, and etc., is all part of normal installation and will not be paid for under warranty. If a
warranty technician is called out and finds the unit improperly installed, the end user may be subject to billing.
FOR MAINTENANCE, SERVICE, REPAIRS, OR INSTALLATION - Contact your dealer or the factory, for your local Factory Authorized
Service Agency.
The gas pressure regulator provided with the equipment must be installed when the appliance is connected to the gas supply.
The area around the appliance must be kept free and clear of combustibles such as solvents, cleaning liquids, brooms, rags, etc.
Proper clearances must be provided at the front of the appliances for servicing and proper operation.
Provisions shall be incorporated in the design of the kitchen, to ensure an adequate supply of fresh air and adequate clearance for
air operanings into the combustion chamber, for proper combustion and ventilation.
For proper operation of the appliance, do not obstruct the ow of combustion and ventilation air.
The installation must conform with local codes, or in the absence of local codes, with the national fuel gas code, ANSI Z223.1 - 1988
(or latest addenda).
The gas supply line must be at least 3/4" NPT.
INSTALLATION - GAS STANDARDS AND CODES
1. The appliance and its individual shut off valve must be disconnected from the gas supply piping system during any pressure testing
of that system at test pressure in excess of 1/2 psi (3.45 kPa).
2. The appliance must be isolated from the gas supply piping system by closing the individual manual shut-off valve during any
pressure testing of the gas supply piping system at test pressures equal to or less than 1/2 PSI.
IMPORTANT - The installation of this appliance must conform to local codes or, in the absence of local codes, with the National Fuel
Gas Code ANSI Z223.1, Natural Gas Installation Code, CAN/CGA-B149-1, or the Propane Installation Code, CAN/CGA-B149-2 as
applicable, incluiding:
GAS INSTALLATION INSTRUCTIONS