Vision Turbine Meters
Models BV1000 and BV2000
for Low Viscosity and Non-Aggressive Liquids
DESCRIPTION
The Vision Turbine Meters are Bisphenol A (BPA)-free
meters that comply with the lead-free provisions of the
Safe Drinking Water Act. The meters are designed for flow
measurement of demineralized water, alkaline solutions, oils,
salad oil, fuel/fuel consumption, beverages, water solutions,
and coolants.
• The BV1000 flow range is 0.026…0.65 gpm
(0.1…2.5 lpm)
• The BV2000 flow range 0.13…9.2 gpm
(0.5…35 lpm)
The meter is especially suitable for washing machines,
dishwashers, coffee machines, laser cooling plants, solar
solutions, bakery machines, steam cooking machines in
large kitchen plants, and CD or DVD cleaning.
INSTALLATION
Guidelines
• Check compatibility of liquid with the
meter material.
• Install a 50 micron filter in front of the meter, if needed,
to remove solid ingredients. Do not use on fluids with
fibrous content or contamination.
• Install sensor into properly cleaned pipeline only.
• Check electrical connection according to the electrical
wiring plan.
• Prior to installation, confirm system versus
sensor specifications.
• Filter the system to 50 microns prior to the sensor, and
minimize pulses/water hammer effects to prevent unit
damage.
• Observe the arrow on the bottom of the unit for correct
inlet and outlet port. Sensor can be mounted in any
horizontal, vertical, or skewed orientation.
• Correctly installed, the sensor works
maintenance-free.
Installing 1/4" and 3/8" NPT Units
1. Apply a small amount of thread sealant (Permatex “No
More Leaks” ®) or Teon® tape to male threads.
OTE:N Make sure that the sealant does not enter into the
turbine and bearing internal area.
2. Hand tighten unit in place.
3. Turn an additional 1/4 turn to seal. If the seal leaks,
turn an additional 1/4 turn or until the leak stops.
Do not exceed one additional turn total beyond
hand tightening.
Installing G 1/4" and G 3/8" Units
The G 1/4" and G 3/8" units mate with a flat face seal washer,
similar to a garden hose arrangement. This arrangement
requires no sealants; hand tightening should be sufficient
for sealing.
VIS-UM-00021-EN-02 (July 2014)
User Manual

ELECTRICAL CONNECTIONS
Output Signal
The output signal is a square wave signal where the frequency is proportional to the flow rate. An external, user-supplied
pull-up resistor is required to ensure that the open collector will sink less than 20 mA. Applying a current greater than 20 mA
may damage the sensor.
Wiring Diagram
5. . .24 V DC
0 V DC
1.2. . .2.2K Ohms
Customer Supplied
OUTPUT
With DIN Connector
Function DIN Termination
V+ 1
–
Output 2
Cable Connection
Brown
Black
Red
SPECIFICATIONS
Model
Flow
Range
K-Factor
Frequency
Output
BV1000 BV2000
025 050 075 100 150 250 350
0.026…0.65 gpm 0.13…1.3 gpm 0.13…2.0 gpm 0.26…2.7 gpm 0.26…4.0 gpm 0.26…6.6 gpm 0.53…9.2 gpm
0.1…2.5 lpm 0.5…5 lpm 0.5…7.5 lpm 1…10 lpm 1…15 lpm 1…25 lpm 2…35 lpm
70,000 ppg 26100 ppg 17800 ppg 12500 ppg 8300 ppg 3785 ppg 2840 ppg
18,500 ppl 6900 ppl 4700 ppl 3300 ppl 2200 ppl 1000 ppl 750 ppl
30…770 Hz 58…575 Hz 38…575 Hz 55…550 Hz 37…550 Hz 17…416 Hz 25…437 Hz
OPERATION GUIDELINES
• Do not exceed the specific indications.
• The Vision Series meter is a volumetric measuring device. Any air/gas in the liquid will be included in
measured volume.
• Correctly installed, the sensor is maintenance free.
0V DC
5. . .24V DC
• Do not blow out the turbine flow meter with compressed air. This may damage the bearings.
Control. Manage. Optimize.
Trademarks appearing in this document are the property of their respective entities. Due to continuous research, product improvements and enhancements, Badger Meter reserves
the right to change product or system specications without notice, except to the extent an outstanding contractual obligation exists. © 2014 Badger Meter, Inc. All rights reserved.
www.badgermeter.com
The Americas | Badger Meter | 4545 West Brown Deer Rd | PO Box 245036 | Milwaukee, WI 53224-9536 | 800-876-3837 | 414-355-0400
México | Badger Meter de las Americas, S.A. de C.V. | Pedro Luis Ogazón N°32 | Esq. Angelina N°24 | Colonia Guadalupe Inn | CP 01050 | México, DF | México | +52-55-5662-0882
Europe, Middle East and Africa | Badger Meter Europa GmbH | Nurtinger Str 76 | 72639 Neuen | Germany | +49-7025-9208-0
Europe, Middle East Branch Oce | Badger Meter Europe | PO Box 341442 | Dubai Silicon Oasis, Head Quarter Building, Wing C, Oce #C209 | Dubai / UAE | +971-4-371 2503
Czech Republic | Badger Meter Czech Republic s.r.o. | Maříkova 2082/26 | 621 00 Brno, Czech Republic | +420-5-41420411
Slovakia | Badger Meter Slovakia s.r.o. | Racianska 109/B | 831 02 Bratislava, Slovakia | +421-2-44 63 83 01
Asia Pacic | Badger Meter | 80 Marine Parade Rd | 21-06 Parkway Parade | Singapore 449269 | +65-63464836
China | Badger Meter | 7-1202 | 99 Hangzhong Road | Minhang District | Shanghai | China 201101 | +86-21-5763 5412