Recordall®
Transmitter Register (RTR)
DESCRIPTION
APPLICATIONS: The Recordall® Transmitter Register (RTR®) is
designed for use with all Recordall Disc, Turbo, Compound and
Fire Service Meters to provide output compatibility with ORION®,
GALAXY, Itron® ERT®, and Badger Meter, Inc. approved AMR
technology solutions.
RESOLUTION: Digital output from the RTR typically has resolution
of 1/10th of the register test circle (resolution may vary in some
cases). The electronic resolution table in this brochure lists
minimum output resolution for all Recordall meter applications.
MOUNTING: The RTR in its shroud assembly uses a bayonet mount
compatible with all Recordall Disc and Turbo meters. A TORX® seal
screw is provided to allow positioning of the register for the most
convenient reading and to secure the register to the meter body in
a tamper resistant mode. The RTR can be removed from the meter
without disrupting water service.
MAGNETIC DRIVE: Direct drive high-strength magnetic coupling
through the meter body to the wetted magnet provides reliable
and dependable register coupling.
SEALED REGISTER: The RTR local register consists of a six-digit
straight-reading mechanical odometer totalizer (located in the
six o’clock position), a 360° test circle with sweep hand, and a
flow finder to detect leaks. The register gearing is self-lubricating
thermoplastic to minimize friction and provide long, reliable
life. Permanent sealing eliminates moisture, dirt, and other
contaminants. The leak rate of the seal is less than 10-6 cc/sec as
tested by a helium mass spectrometer.
TAMPER-PROOF FEATURES: Customer removal of the RTR can be
prevented by using a tamper resistant TORX seal screw. TORX seal
screws are provided as standard accessories with the RTR. Optional
tamper detection seal wire screws are also available.
CONSTRUCTION: The housing of the RTR is constructed of a
strengthened glass lens top and a corrosion-resistant metal
bottom. Internal construction materials are thermoplastics for longlife and high reliability. The integrity of the adhesive seal joining
the glass top to the metal base provide unmatched protection in
water meter applications. A corrosion and tamper resistant TORX
seal screw is provided to secure the RTR to the meter. The shroud
assembly is thermoplastic.
TEMPERATURE: The operating range of the RTR is
–40…49° C (–40…120° F). The water meter should not be
subjected to temperatures below freezing.
MOISTURE: The RTR achieves true water resistance due to the
adhesive technology used in the sealing process. Leak rates less
than 10-6 cc/sec, as tested by a helium mass spectrometer, are
comparable to a true hermetic seal. Due to this unique sealing
process, the RTR exceeds all applicable requirements of AWWA
Standard C707 regarding moisture intrusion. Register fogging and
condensation are no longer an issue.
WIRE CONNECTIONS: The RTR is provided as either a factory
prewired assembly or as a register with pre-sized wire harness
available for connection in the field.
SPECIFICATIONS
Transmitter/Register Straight reading, permanently sealed,
magnetic drive
Unit of Measure U.S. gallons, cubic feet, cubic meters, clearly
identified on register face
Number Wheels Six with 3/16” high numerals font type
Test Circle 360° circle with ten major increments with
ten divisions each
Weight 9 ounces
Humidity 0…100% condensing
Temperature
Signal Characteristics Open Drain (FET )
Visual Resolution 1/100th of Test Circle
Electronic Resolution 1/10th of Test Circle
Typical Signal Duration 15…75 ms @ 25° C (77° F) 8…75 ms over
On State Resistance 7.5 Ohms @ 25° C (77° F)
Power Source External
Maximum Switching 30V DC @ 1 mA @ 25° C (77° F)
ELECTRONICS: The piezoelectric switch circuit board is completely
sealed against moisture inside the unit and sealed to ensure
protection from humidity.
ELECTRICAL: The electronic circuitry is designed to provide
immunity to electrical surges and transients per IEC801-2, IEC801-4
Severity Level 4.
OPERATING CHARACTERISTICS: The RTR has an output equal to
1/10th of the meter test circle with the characteristics of an open
drain FET. The on-state condition is a solid-state switch closure. Offstate condition is an open circuit. Powered by an external source,
the RTR has a maximum rating of 30V DC at 1 mA (25° C).
–40…49° C (–40…120° F)
operating temperature range at 67 µA
RTR-T-05-EN (April 2012)
Technical Brief
Technical Brief

RTR Register
Dimensional Drawing
MEASUREMENT RESOLUTION: The minimum electronic resolution
of the RTR is as noted below. To verify the correct resolution for your
application, contact your Badger Meter regional sales office.
RECORDALL
Disc Series
M25 5/8” 1 0.1 0.01
M25 3/4” 1 0.1 0.01
M35 3/4” 1 0.1 0.01
M40 1” 1 0.1 0.01
M55 1” 1 0.1 0.01
M70 1” 1 0.1 0.01
M120 1-1/2” 10 1 0.1
M170 2” 10 1 0.1
RECORDALL
Turbo Series
1-1/2” 100 10 0.1
2” 100 10 0.1
3” 100 10 0.1
4” 100 10 0.1
6” 100 10 1
8” 100 10 1
10” 100 10 1
12” 1000 100 1
16” 1000 100 10
20” 1000 1000 10
Resolution
Size
Resolution
Gallons
Gallons
Resolution Cubic
Feet (ft3)
Resolution
Cubic Feet (ft3)
Resolution Cubic
Meters (m3)
Resolution Cubic
Meters (m3)
Fire Service
Meters
3” 100 10 0.1
4” 100 10 0.1
6” 100 10 1
8” 100 10 1
10” 100 10 1
RECORDALL
Compound
Series
2” 100 10 0.1
3” 100 10 0.1
4” 100 10 0.1
6” 100 10 1
Resolution
Gallons
Resolution
Gallons
Resolution
Cubic Feet (ft3)
Resolution
Cubic Feet (ft3)
Resolution
Cubic Meters
(m3)
Resolution
Cubic Meters
(m3)
Resolution stated as summed total with (2) RTRs, Summator/
Splitter and a single AMR module. Please see the Turbo Series and
Disc Series sections for individual high and low side resolution.
Fire Series
Assemblies
(FSA)
4” 100 10 0.1
6” 100 10 1
8” 100 10 1
10” 100 10 1
Resolution
Gallons
Resolution
Cubic Feet (ft3)
Resolution
Cubic Meters
(m3)
IMPORTANT
The RTR® should only be connected to a Badger Meter, Inc.
approved product. Connection to an unapproved product will void
the RTR warranty.
Resolution stated as summed total with two RTRs, Summator/
Splitter and a single AMR module. Please see the Turbo Series
and Disc Series sections for individual mainline and by-pass
resolution.
www.badgermeter.com
ORION, Recordall, and RTR are registered trademarks of Badger Meter, Inc.
Other trademarks appearing in this document are the property of their respective entities.
Due to continuous research, product improvements and enhancements, Badger Meter reserves the right to change product or system specications without notice,
except to the extent an outstanding contractual obligation exists. © 2012 Badger Meter, Inc. All rights reserved.
Badger Meter | PO Box 245036, Milwaukee, Wisconsin 53224-9536 | 800-876-3837 | infocentral@badgermeter.com