Flow Instrumentation
PFV Venturi Fire Pump System with
Model GMD or GMD-B Indicating Meter
VEN-UM-00862-EN-02 (April 2014)
User Manual
INSTALLATION INSTRUCTIONS
• Install the sensor so the flow arrow or the indicated inlet is the correct direction of flow.
• The sensor can be installed in any position. The recommended position is with high or low pressure taps in a horizontal
position.
• Install upstream (Hi) with Hi pressure port of meter. Install downstream (Lo) with Lo pressure port of meter.
5
1
4
3000
2500
GPM
FM
3500
2000
APPROVED
1500
1000
4000
PFB-XXX
X Inch
250 SWP
X/XX
S/N AXXXXXXX
2
3
1
PFV - USUAL
4
3000
2500
GPM
FM
3500
2000
APPROVED
1500
1000
4000
PFB-XXX
X Inch
250 SWP
X/XX
S/N AXXXXXXX
2
3
PFV - OTHER
LEGEND:
1. PRESO Primary Element - Annular
2. PRESO GMD Meter
3. Tubing or piping by others
4. Shut-o, equalizing valves and/or manifolds by others
5. Condensation or separation chamber by others
3000
2500
GPM
FM
3500
2000
Discharge
Air Vent
Throttle Valve
APPROVED
1500
1000
4000
PFB-XXX
X Inch
250 SWP
X/XX
S/N AXXXXXXX
System By-pass
Valve
FLOW
Preso
Optional to
Pump Inlet
PFV
Pipe Diameters from Valve
(7)(3)
FLOW
System ValveValve
Supply
FLOW
Fire Pump
Typical Piping Conguration
Control. Manage. Optimize.
PRESO is a registered trademark of Badger Meter, Inc. Other trademarks appearing in this document are the property of their respective entities. Due to continuous research,
product improvements and enhancements, Badger Meter reserves the right to change product or system specications without notice, except to the extent an outstanding
contractual obligation exists. © 2014 Badger Meter, Inc. All rights reserved.
www.badgermeter.com
The Americas | Badger Meter | 4545 West Brown Deer Rd | PO Box 245036 | Milwaukee, WI 53224-9536 | 800-876-3837 | 414-355-0400
México | Badger Meter de las Americas, S.A. de C.V. | Pedro Luis Ogazón N°32 | Esq. Angelina N°24 | Colonia Guadalupe Inn | CP 01050 | México, DF | México | +52-55-5662-0882
Europe, Middle East and Africa | Badger Meter Europa GmbH | Nurtinger Str 76 | 72639 Neuen | Germany | +49-7025-9208-0
Europe, Middle East Branch Oce | Badger Meter Europe | PO Box 341442 | Dubai Silicon Oasis, Head Quarter Building, Wing C, Oce #C209 | Dubai / UAE | +971-4-371 2503
Czech Republic | Badger Meter Czech Republic s.r.o. | Maříkova 2082/26 | 621 00 Brno, Czech Republic | +420-5-41420411
Slovakia | Badger Meter Slovakia s.r.o. | Racianska 109/B | 831 02 Bratislava, Slovakia | +421-2-44 63 83 01
Asia Pacic | Badger Meter | 80 Marine Parade Rd | 21-04 Parkway Parade | Singapore 449269 | +65-63464836
China | Badger Meter | 7-1202 | 99 Hangzhong Road | Minhang District | Shanghai | China 201101 | +86-21-5763 5412 Legacy Document Number: PFV_Instruction